B. Using Hand-Held Wireless Remote Control

24

OPERATING FIREPLACE

Normal Lighting Instructions (Cont.) To Turn Off Gas To Appliance

Manual Lighting Instructions for Electrical Power Outage

OPERATING FIREPLACE

Continued

B. Using Hand-Held Wireless Remote Control

1.Set manual ignition bypass switch on control panel to OFF position (automatic ignition position).

2.Wait five (5) minutes to clear out any gas. Smell for gas around heater and near floor. If you smell gas, STOP! Fol- low “B” in the safety information on warnings plate. If you don’t smell gas, go to the next step.

3.Point remote control toward the lower front of fireplace and push both buttons at the same time. Hold for 6 sec- onds. The gas valve will open and electronic ignition will begin sparking to light the pilot. Note: You will be able to hear a clicking sound during this process. LED on wall switch will light.

Note: You may be running this heater for the first time after connecting to gas supply or at the start of your heat- ing season. If so, the ON button may need to be pressed again. This will allow air to bleed from gas system. If sev- eral attempts to light pilot fail, contact a qualified service person or gas supplier for repairs. Until repairs are made, light and operate manually (see Manual Lighting Instruc- tions for Electrical Power Outage).

4.When pilot flame is lit, the thermocouple is heated by the flame. When thermocouple becomes hot (5 to 15 seconds), main burner will automatically light on high flame.

5.To lower flame, point remote control toward lower front of fireplace and push HI/LO button once.

Note: This fireplace does not have a pilot-only mode.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater - Wall Switch

Push ON/OFF button on wall switch once.

Shutting Off Heater - Wireless Remote Control

Point remote control toward lower front of fireplace and push both buttons at the same time.

MANUAL LIGHTING

INSTRUCTIONS FOR

ELECTRICAL POWER OUTAGE

Shutting Off Heater - Wall Switch WARNING: You must operate this heater with the fireplace screen in place. Make sure fireplace screen is in place before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

Because this fireplace has an electronic ignition system, in the event there is a loss of power, it will be necessary to manually light the pilot with the piezo ignitor. After the pilot is lit, the main burner will light automatically.

1.Follow steps 1 through 3 under Normal Lighting Instructions, page 23.

2.Set manual ignition bypass switch on control panel to ON position (manual ignition position). See Figure 50.

3.The pilot is attached to the rear of the front burner. You will be able to see the pilot and spark electrode without removing the screen or logs.

4.Place the magnetic manual override handle, provided with this unit, on the end of the gas valve stem (see Figure 50).

5.Turn the override handle fully counterclockwise Shutting Off Heater - Wireless Remote Control to the PILOT position. The handle will not stop but will begin to slip when you have fully turned to the PILOT position.

6.While holding the valve handle in the PILOT position, press and release piezo ignitor button (see Figure 50). This will light the pilot. If needed, keep pressing ignitor button until pilot lights.

7.When pilot flame is lit, hold manual override handle until ther- mocouple heats (approximately 5 to 15 seconds). If pilot goes out, repeat process. If several attempts to light the pilot fail, contact a qualified service person or gas supplier for repairs.

8.When thermocouple is heated, release override handle. The main burner will immediately light on high flame. Adjust flame size by turning override handle.

Gas Valve

Piezo Ignitor

 

 

 

HI/LO

 

 

Manual Ignition

 

 

MANUAL

Bypass Switch

 

Button

 

 

 

IGNITION

(Down is ON)

 

 

 

 

 

 

 

Magnetic Manual

HI LO

ON OFF

 

Override Handle

 

 

 

 

 

Wall

LED

ON/OFF

LED

 

Switch

 

 

 

Button

 

Figure 50 - Control Locations

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111245-01A

Page 24
Image 24
Desa CGEFP33PRB, CGEFP33NRB installation manual Operating Fireplace, Continued, B. Using Hand-HeldWireless Remote Control