30
SPECIFICATIONS
SERVICE HINTS TECHNICAL SERVICE REPLACEMENT PARTS
SPECIFICATIONS
Btu (Variable) | 20,000/33,000 |
|
Type Gas | Natural: CGEFP33NRB | |
| Propane/LP: CGEFP33PRB | |
Ignition | Electronic (Automatic)/Piezo (Manual) | |
| Natural Gas | Propane/LP Gas |
Manifold Pressure | 3.5" W.C. | 8.0" W.C. |
Inlet Gas Pressure (in. of water) |
| |
Maximum | 10.5" | 14" |
Minimum* | 5" | 11" |
Shipping Weight | 122 lbs. | 122 lbs. |
* For input adjustment |
|
|
SERVICE HINTS
When Gas Pressure Is Too Low
•pilot will not stay lit
•burners will have delayed ignition
•heater will not produce specified heat
•for propane/LP units, propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.
TECHNICAL SERVICE
You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at
You can also visit DESA Heating Products’ technical service web site at www.desatech.com.
REPLACEMENT PARTS
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA Heating Products’ Techni- cal Service Department at
When calling DESA Heating Products, have ready
•your name
•your address
•model and serial numbers of your fireplace
•how fireplace was malfunctioning
•type of gas used (propane/LP or natural gas)
•purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product or Parts Central (see page 41). If they can’t supply original replacement part(s), call DESA Heating Products at
When calling DESA Heating Products, have ready
•model number of your fireplace
•the replacement part number
For..com