Optima Company Comprehensive Guide for Archgard Water Heaters: Optima 34 and 45 Models

Page 23

Optima 45 - 3

23

LOG PLACEMENT

Archgard chooses ceramic fiber logs for use in the Optima 45-3. The logs are designed to give a realistic fire package, and are created for long life, to give you the same beautiful look as the day they were originally installed. Care must be given when first installing the logs and if removed for servicing, as they can be damaged or broken if not handled properly. Please note that logs may vary slightly in size and shape but does not affect performance.

Gas and vent connection must be made before installing the ceramic fiber logs on the burner.

NOTE: Improper placement of logs may cause sooting on the internal parts and glass, and will not be covered under warranty. Do not use broken or damaged logs.

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

LOG #83

LOG #142

LOG #12

LOG #80

LOG #74

 

LOG #13

 

 

 

PLATINUM EMBERS

NOTE: Installing the ceramic logs in any other position other than shown will result in flame impingement causing sooting of the logs, brick liner and ceramic glass viewing area.

Image 23
Contents Optima 45 Page Introduction Table of Contents Optima 45 SafetyAppliance Certification Installation CodesSpecifications High Altitude InstallationGAS Connections Natural Gas Pressure SettingsPropane Pressure Settings Appliance Description Appliance DimensionsAlcove Installation Dimensions and ClearancesVent Termination Locations Locating GAS HeaterTermination Locations Venting Connection Approved Vent ComponentsSimpson Dura-Vent Archgard System Venting Restrictor Placement71 M Venting ChartVenting Vertical Termination Using Simpson DURA-VENT Pipe Feet Termination Framing Spring Spacers Venting Horizontally Using Archgard TVK-FSU Vent KITInstallation Procedures for Archgard Snorkel KIT SNK-24 Venting below Grade Using Flexible Direct Vent SystemsCorner Installations Flat Wall InstallationSet the Optima 45-3 in its desired location Optima 45 Below Grade Above Grade LOG Placement Burner Pan & Pin Locations Piece LOG SET Shown belowLocate Log # 12 and place it on the burner pins as shown Locate Log #142 and place it on Log #12 as shown LOG #83 Ceramic Brick Panels Front ViewValve Connection for Millivolt Valve Optional Wall Switch or ThermostatInitial Operation Final Installation CheckLighting Instructions Caution First FireLighting Instructions Lighting Instructions on Rating PlateReplacing the Glass Door Glass Door RemovalIf Your Glass Breaks Removing the Glass DoorTroubleshooting Troubleshooting Regularly Maintenance Cleaning the ApplianceAdjusting Primary AIR Servicing Under WarrantyAdjusting Primary AIR Changing Main Burner Orifice Checking Inlet and Outlet GAS Pressure Checking and Adjusting Pilot Convertible Pilot OrificeCanadian Electrical code, CSA C22.1 Wiring DiagramReplacing Convection Blower Item # Item Description Qty Unit Valve Tray AssemblyBurner Pan & Pin Locations Item # Item Description Qty Unit Parts List Ceramic Logs and Burner PanCeramic Brick Replacement Parts List Archgard OptimaQty Unit Archgard Limited Warranty Frequently Asked Questions Optima 45 Page Warranty Registration Beatty Drive MISSION, B.C. Canada

45 - 3 specifications

Optima Company 45 - 3 is an innovative product in the realm of advanced manufacturing and technology. This state-of-the-art machine has gained attention for its unique blend of efficiency, precision, and adaptability, making it a preferred choice for various industries, including automotive, aerospace, and electronics.

One of the standout features of the Optima Company 45 - 3 is its versatility. The machine is designed to handle a wide range of materials, from metals to plastics, enabling manufacturers to utilize it across multiple projects without extensive modifications. This flexibility not only saves time and resources but also streamlines the production process, allowing businesses to respond quickly to market demands.

Equipped with cutting-edge technologies, the Optima Company 45 - 3 boasts advanced automation capabilities. This includes integrated robotics and smart sensors that facilitate real-time monitoring and adjustments during operation. These features help ensure optimal performance levels, reducing the risk of errors and minimizing downtime, ultimately translating to a higher return on investment for users.

In terms of precision, the Optima Company 45 - 3 employs advanced CNC (Computer Numerical Control) technology. This allows for intricate designs and specifications to be followed with remarkable accuracy. The millimeter-perfect cuts and finishes not only enhance the quality of the final product but also reduce the need for additional post-processing, which can be time-consuming and costly.

Another significant characteristic of the Optima Company 45 - 3 is its energy efficiency. In a world where sustainability is paramount, the machine is designed to operate using less power without compromising on performance. This environmentally friendly approach not only lowers operational costs but also aligns with green initiatives that many companies are striving to achieve.

Moreover, the user interface of the Optima Company 45 - 3 has been simplified to ensure ease of operation. The intuitive controls allow even novice operators to manage complex tasks with minimal training, thereby reducing the learning curve associated with traditional manufacturing equipment.

In conclusion, the Optima Company 45 - 3 sets a new benchmark in the manufacturing landscape. Its combination of versatility, precision, automation, energy efficiency, and user-friendliness makes it an invaluable asset for companies looking to enhance their production capabilities and stay competitive in a fast-evolving market.