Optima Company 45 - 3 manual Servicing Under Warranty, Adjusting Primary AIR

Page 37

Optima 45 - 3

37

SERVICING UNDER WARRANTY

Before servicing, read the Terms and Conditions of the Archgard Warranty at the back of the manual. Contact the Authorized Archgard dealer where you purchased the appliance and provide them with details of the problem together with the initial installation information (from the back of this manual).

WARNING: Servicing of this appliance must be conducted by a qualified service technician. Improper servicing, adjustment or alteration of this appliance may cause property damage, personal injury or loss of life. All servicing should be conducted with the appliance cold. All replacement parts must be authorized by Archgard for suitability.

ADJUSTING PRIMARY AIR

Caution: Wear gloves when adjusting the primary air with the appliance hot.

Note: the Shutter is set at the factory and normally only requires resetting at higher altitudes.

1.Unscrew the 2 screws holding the control panel and remove the panel.

2.The primary air adjustment wing nut is located behind and to the left of the control valve.

3.Loosen the wing nut and slide the primary air shutter to the right to increase primary air and to left to reduce primary air.

4.Tighten the wing nut after adjustment.

Air Shutter (Side View)

Image 37
Contents Optima 45 Page Introduction Table of Contents Optima 45 SafetySpecifications Installation CodesHigh Altitude Installation Appliance CertificationPropane Pressure Settings Natural Gas Pressure SettingsGAS Connections Appliance Description Appliance DimensionsAlcove Installation Dimensions and ClearancesVent Termination Locations Locating GAS HeaterTermination Locations Venting Connection Approved Vent ComponentsSimpson Dura-Vent Archgard System Venting Restrictor Placement71 M Venting ChartVenting Vertical Termination Using Simpson DURA-VENT Pipe Feet Termination Framing Spring Spacers Venting Horizontally Using Archgard TVK-FSU Vent KITInstallation Procedures for Archgard Snorkel KIT SNK-24 Venting below Grade Using Flexible Direct Vent SystemsCorner Installations Flat Wall InstallationSet the Optima 45-3 in its desired location Optima 45 Below Grade Above Grade LOG Placement Burner Pan & Pin Locations Piece LOG SET Shown belowLocate Log # 12 and place it on the burner pins as shown Locate Log #142 and place it on Log #12 as shown LOG #83 Ceramic Brick Panels Front ViewValve Connection for Millivolt Valve Optional Wall Switch or ThermostatInitial Operation Final Installation CheckLighting Instructions Caution First FireLighting Instructions Lighting Instructions on Rating PlateIf Your Glass Breaks Glass Door RemovalRemoving the Glass Door Replacing the Glass DoorTroubleshooting Troubleshooting Regularly Maintenance Cleaning the ApplianceAdjusting Primary AIR Servicing Under WarrantyAdjusting Primary AIR Changing Main Burner Orifice Checking Inlet and Outlet GAS Pressure Checking and Adjusting Pilot Convertible Pilot OrificeReplacing Convection Blower Wiring DiagramCanadian Electrical code, CSA C22.1 Item # Item Description Qty Unit Valve Tray AssemblyBurner Pan & Pin Locations Item # Item Description Qty Unit Parts List Ceramic Logs and Burner PanQty Unit Replacement Parts List Archgard OptimaCeramic Brick Archgard Limited Warranty Frequently Asked Questions Optima 45 Page Warranty Registration Beatty Drive MISSION, B.C. Canada

45 - 3 specifications

Optima Company 45 - 3 is an innovative product in the realm of advanced manufacturing and technology. This state-of-the-art machine has gained attention for its unique blend of efficiency, precision, and adaptability, making it a preferred choice for various industries, including automotive, aerospace, and electronics.

One of the standout features of the Optima Company 45 - 3 is its versatility. The machine is designed to handle a wide range of materials, from metals to plastics, enabling manufacturers to utilize it across multiple projects without extensive modifications. This flexibility not only saves time and resources but also streamlines the production process, allowing businesses to respond quickly to market demands.

Equipped with cutting-edge technologies, the Optima Company 45 - 3 boasts advanced automation capabilities. This includes integrated robotics and smart sensors that facilitate real-time monitoring and adjustments during operation. These features help ensure optimal performance levels, reducing the risk of errors and minimizing downtime, ultimately translating to a higher return on investment for users.

In terms of precision, the Optima Company 45 - 3 employs advanced CNC (Computer Numerical Control) technology. This allows for intricate designs and specifications to be followed with remarkable accuracy. The millimeter-perfect cuts and finishes not only enhance the quality of the final product but also reduce the need for additional post-processing, which can be time-consuming and costly.

Another significant characteristic of the Optima Company 45 - 3 is its energy efficiency. In a world where sustainability is paramount, the machine is designed to operate using less power without compromising on performance. This environmentally friendly approach not only lowers operational costs but also aligns with green initiatives that many companies are striving to achieve.

Moreover, the user interface of the Optima Company 45 - 3 has been simplified to ensure ease of operation. The intuitive controls allow even novice operators to manage complex tasks with minimal training, thereby reducing the learning curve associated with traditional manufacturing equipment.

In conclusion, the Optima Company 45 - 3 sets a new benchmark in the manufacturing landscape. Its combination of versatility, precision, automation, energy efficiency, and user-friendliness makes it an invaluable asset for companies looking to enhance their production capabilities and stay competitive in a fast-evolving market.