Installation Instructions
Remote Control/
Wall Thermostat
A
Metal cover over recessed connection space
The Zoneline can be controlled by using the controls on the unit or by a wall thermostat.
Detailed wiring instructions are packed with the
To switch to a wall thermostat, move switch 10 to the ON (up) position (see illustration B at left). Connect the unit to a
For some applications, it may be desirable to operate on low fan speed. Moving the auxiliary switch 11 to the ON (up) position will pro- vide low fan speed in both heating and cooling modes.
No external voltage may be applied to the unit through the Remote Thermostat terminals.
IMPORTANT:
B
Class 2
Remote
Thermostat
ON
OFF
Low fan speed
with Class 2
Remote
Thermostat
10 11
ON
OFF
Remote Thermostat (GE Model RAK147 or equivalent), as shown in illustration C at left.
After the wire connections are completed, replace the metal cover to prevent damage to the unit or personal injury.
Auxiliary Controls
C |
| 6P Plug |
|
Insert
1 |
RED | GRY | BLK YEL | WHT | BLU | |
|
|
|
|
| Wire nut |
|
|
|
|
| 6 PCS |
+24V | FANMOT. | SOL.COIL | COMP. | HEATER | RAK147 |
GND | |||||
|
|
|
|
| or equivalent |
R G B Y W C T’Stat terminals Class 2 Thermostat
16