GE 5100 installation instructions Fan Switch, Freeze Sentinel

Page 7

Fan Switch

 

 

 

 

 

 

Fan switch

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

ON

 

 

 

OFF

 

 

 

 

 

 

 

 

 

OFF

 

 

 

Auxiliary Controls

Down/Off—Continuous Fan Up/On—Cycle Fan

The fan switch 9 is located behind the room cabinet.

This switch is set at continuous fan (down) at the factory to provide continuous fan operation in cool or heat modes. Leaving the switch in the continuous fan setting allows continuous circulation of room air and will result in a more balanced temperature throughout the room.

If you want the fan to cycle on and off with the compressor or with the heater, move the switch to cycle fan (up).

Freeze Sentinel

The Freeze Sentinel feature automatically turns on the resistance heater and fan if the room temperature (sensed at the unit) drops to approximately 40°F. It will turn the heater off when the temperature reaches about 45°F.

The Freeze Sentinel helps prevent plumbing damage in the room due to sub-freezing temperatures.

The Freeze Sentinel is active as long as power to the unit is on.

7

Image 7
Contents Zoneline 800.626.2000 Before using your ZonelineWrite down the model and serial Replacing an existing unit? Read ALL Safety Information Before UsingControls on your Zoneline Mode ControlVentilation Control About Your Heat Pump Other Zoneline featuresFreeze Sentinel Fan SwitchRoom Cabinet and Case Care & CleaningOutdoor Coils Base PanAir Filters Replacing a ducted chassis Replacing 230/208 volt units Read carefullyUse the correct wall case Use the correct outdoor grilleImportant Notes Important electrical safety-read carefullyZoneline Components 230/208 Volt Electrical Supply How to ConnectVolt Electrical Supply Install the Wall Case and Exterior Grille Power Connection ChartInsulated Wall Case Replace the Room Cabinet Install the Unit into the Wall CaseBoost Heat Option Low Voltage Connectors & Auxiliary ControlsElectric Heat Option PCS Remote Control Wall ThermostatCentral Desk Control Do not use a common buss in the CDC wiringTemperature Limiting Diagnosis SwitchNoise Things that are normalExplanation What to Do Before you call for serviceZoneline Does Not Cool or Heat as it Should Zoneline Doesn’t StartAir is Not Always Cool or Hot During Operation Call SVC Indicator LightBurning Odor at Start of Heating Operation Heating OperationPage We’ll be there Further ServiceOn-Site Repair Service Parts and AccessoriesWhat is Not Covered What is Covered

5100 specifications

The GE 5100 is a state-of-the-art gas turbine engine developed by General Electric, designed to offer unparalleled efficiency and reliability for power generation. This advanced engine has been engineered with a focus on innovative technology and cutting-edge materials, making it a favorable choice for utility companies and independent power producers around the globe.

One of the main features of the GE 5100 is its remarkable efficiency. With a simple cycle efficiency surpassing traditional gas turbines, the GE 5100 ensures that utility providers can generate more electricity from the same amount of fuel. This is crucial in today’s energy landscape, where operational costs and environmental concerns are top priorities.

The GE 5100 employs a modular design that facilitates maintenance and reduces downtime. The engine consists of easy-to-replace modules, enabling rapid service without extensive disassembly. As a result, power plants using the GE 5100 experience enhanced availability and lower operational costs.

In terms of technology, the GE 5100 utilizes advanced aerodynamics, which optimizes airflow through the turbine and enhances its overall performance. The blade design has been refined using sophisticated computational fluid dynamics (CFD) simulations, which allow engineers to predict performance accurately while minimizing drag and maximizing thrust.

Another notable characteristic of the GE 5100 is its durability. The engine is constructed using high-performance materials that can withstand extreme temperatures and pressures. This robustness not only extends the life of the engine but also ensures reliability even in the most demanding operational environments.

Furthermore, the GE 5100 incorporates an advanced control system that enables operators to monitor performance in real-time, adjusting parameters for optimal efficiency. This level of precision helps to optimize fuel consumption while adhering to emissions regulations, making it a greener option in power generation.

In summary, the GE 5100 gas turbine engine stands out for its efficiency, modular design, advanced aerodynamics, durability, and sophisticated control systems. These features make it a compelling choice for energy providers aiming to improve their performance while remaining environmentally responsible. With the ever-evolving landscape of energy demands, the GE 5100 represents a significant leap forward in gas turbine technology, providing reliable and efficient power generation solutions globally.