GE 5100 installation instructions Air Filters

Page 9

Air Filters

Operating Tip:

To maintain optimum performance, clean the filters at least every 30 days.

FRONT

Dirty filter–Needs cleaning

FRONT

Clogged filter–Greatly reduces cooling, heating and airflow.

Turn the Zoneline off before cleaning.

The most important thing you can do to maintain the Zoneline is to clean the filter at least every 30 days. Clogged filters reduce cool- ing, heating and air flow.

Keeping these filters clean will:

Decrease cost of operation.

Save energy.

Prevent clogged heat exchanger coils.

Reduce the risk of premature component failure.

To clean the air filters:

Vacuum off the heavy soil.

Run water through the filters.

Dry thoroughly before replacing.

To remove the air filters:

2 air filters

Pull up

To replace the air filters:

Push down

CAUTION:

DO NOT operate the Zoneline without the filters in place. If a filter becomes torn or damaged it should be replaced immediately.

Operating without the filters in place or with damaged filters will allow dirt and dust to reach the in- door coil and reduce the cooling, heating, airflow and efficiency of the unit.

Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center

or authorized Customer Care® servicers.

9

Image 9
Contents Zoneline Before using your Zoneline 800.626.2000Write down the model and serial Replacing an existing unit? Read ALL Safety Information Before UsingControls on your Zoneline Mode ControlVentilation Control About Your Heat Pump Other Zoneline featuresFreeze Sentinel Fan SwitchOutdoor Coils Care & CleaningBase Pan Room Cabinet and CaseAir Filters Use the correct wall case Read carefullyUse the correct outdoor grille Replacing a ducted chassis Replacing 230/208 volt unitsImportant electrical safety-read carefully Important NotesZoneline Components How to Connect 230/208 Volt Electrical SupplyVolt Electrical Supply Power Connection Chart Install the Wall Case and Exterior GrilleInsulated Wall Case Replace the Room Cabinet Install the Unit into the Wall CaseLow Voltage Connectors & Auxiliary Controls Boost Heat OptionElectric Heat Option PCS Remote Control Wall ThermostatCentral Desk Control Do not use a common buss in the CDC wiringTemperature Limiting Diagnosis SwitchThings that are normal NoiseExplanation Zoneline Does Not Cool or Heat as it Should Before you call for serviceZoneline Doesn’t Start What to DoBurning Odor at Start of Heating Operation Call SVC Indicator LightHeating Operation Air is Not Always Cool or Hot During OperationPage On-Site Repair Service Further ServiceParts and Accessories We’ll be thereWhat is Not Covered What is Covered