GE 8500 Series installation instructions Safety Precautions

Page 2

Safety Instructions

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

WARNING!

Risk of electric shock. Can cause injury or death. For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

Operating Instructions

Care and Cleaning

SAFETY PRECAUTIONS

n This Zoneline must be properly installed in accordance with the Installation Instructions before it is used.

See the Installation Instructions in the back of this manual.

n Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with

a new power supply cord obtained

from the manufacturer and not repaired. Do not use a cord that shows cracks

or abrasion damage along its length or at either the plug or connector end.

n Product must be operated with the electrical plug supplied with the product. Do not replace the electrical plug supplied with the product.

n If the receptacle does not match the plug,

the receptacle must be changed out by a qualified electrician.

n Unplug or disconnect the Zoneline

at the fuse box or circuit breaker before making any repairs.

NOTE: We strongly recommend that

any servicing be performed by a qualified individual.

n All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal.

If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.

nThese R410A Air Conditioner Systems require contractors and technicians to use tools, equipment and safety standards approved for use with this refrigerant.

DO NOT use equipment certified for R22 refrigerant only.

Consumer Support Troubleshooting Tips

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

2

Image 2
Contents Preparation WarrantyAir Filters Model # Serial #Safety Precautions Troubleshooting Controls-dip switchesControls-Dip Switches All Electric Heat Heat pump models onlyDuct Constant on FanOccupancy Sensor Field Supplied Freeze Sentinel Requires room air sensor kit-RAVRMSGEAppliances.com Temperature Limiting Requires room air sensor kit-RAVRMSTemperature limiting during Cool mode Room Air Sensor Requires room air sensor kit Ravrms Controls-terminal connectionsControls-Terminal Connections Also be connected to the remote thermostatMotion Sensor Obtained locally Central Desk ControlRemote Thermostat Door Sensor Obtained locallyVentilation Control Other features of your ZonelineOn/Off Switch About Heat Pumps on some modelsBase Pan Care and cleaningDrain Air FiltersInstallation Recommended branch circuit wire sizes For 230/208 Volt Cord Connections onlyAttach Conduit For 230/208 Volt Direct Connect Applications onlyRemove Junction BOX Cover Important Connection of a 265V AC productMake Wire Lead Connections Inside the Junction BOX Power Connection ChartModel Type Required AccessoriesZoneline Components Electronic ThermostatTypical Utility Closet and Dimensions Top ViewUtility Closet Connection Locations Unit-mounted filter with a field-supplied return Air grille and access door/panelOption Build and Install the Zoneline Base Platform 000 BTU 12,000 BTU 18,000 BTU Install the DrainsDuctwork 390 415 440 465 490 435 485 535Adjust all four leveling legs until the case is level Install and Connect the CaseInstall and Ground Unit to the Case Unit to the CaseConnect the TOP Duct Maximum Wiring Length for Thermostat Connection to the UnitMake Unit Electrical Connections Servicing Connect PowerFinal Check Unit is unplugged Before You Call For Service…Power failure Indoor airflow is restricted Air filter is dirtyNormal Operating Sounds Minute delayThings that are normal Compressor. You may also hear a fan noise stop and startGEAppliances.com Page What GE Will Not Cover Vertical Zoneline WarrantyFor The Period GE Will Replace Model numberConsumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design Studio

8500 Series specifications

The GE 8500 Series represents a remarkable advancement in the realm of industrial gas turbines, combining efficiency, reliability, and flexibility. Designed to meet the demands of current energy markets, this series of turbines is engineered for both baseload and peak-load applications, making it an ideal choice for operators seeking to optimize their energy production.

One of the standout features of the GE 8500 Series is its exceptional thermal efficiency. With a capability of achieving efficiency levels exceeding 60%, these turbines significantly reduce fuel consumption and lower greenhouse gas emissions. This feature not only makes them environmentally friendly but also helps operators reduce operational costs in the long run, positioning them favorably in a competitive energy landscape.

The GE 8500 Series incorporates advanced airfoil technologies that enhance performance. Featuring an innovative blade design, these turbines are capable of operating efficiently across a wide range of operating conditions. The materials used in the construction of the blades are engineered for durability, allowing them to withstand the harsh environments often encountered in power generation. This greatly extends the service life of the turbine and reduces downtime for maintenance.

Another important aspect of the GE 8500 Series is its adaptability. These turbines can utilize various fuels, including natural gas, hydrogen, and biofuels, offering flexibility to operators in terms of resource management. This feature allows utilities to adjust to changing fuel availability and price fluctuations, ensuring consistent energy generation.

The control and monitoring systems integrated into the GE 8500 Series are state-of-the-art, featuring advanced digital control technologies that provide real-time performance data. This allows operators to make informed decisions regarding maintenance and operational adjustments, ultimately enhancing the overall reliability of the power generation system.

In addition to these advancements, the GE 8500 Series is designed with a focus on reduced emissions without compromising performance. The turbines incorporate advanced combustion technologies that facilitate ultra-low emissions, aligning with the global movement toward cleaner energy solutions.

In conclusion, the GE 8500 Series is an exceptional line of gas turbines that combines high efficiency, flexibility, and low emissions. With advanced technologies and robust features, these turbines are positioned to meet the evolving needs of the energy sector while supporting the transition to a more sustainable future.