GE 8500 Series installation instructions Installation

Page 10

Installation

Zoneline Air

Instructions

Conditioners

Questions? Visit our Website at: GEAppliances.com or call 800.GE.CARES (800.432.2737).

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT Save these instructions for local inspector’s use.

IMPORTANT Observe all governing codes and ordinances.

Note to Installer Be sure to leave these instructions with the owner.

Note to Owner Keep these instructions for future reference.

• Proper installation is the responsibility of the installer.

• Product failure due to improper installation is not covered under the Warranty.

• You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.

TOOLS YOU WILL NEED

Phillips screwdriver

Adjustable wrench

Saw

Hammer

IMPORTANT ELECTRICAL SAFETY–READ CAREFULLY

WARNING: RISK OF ELECTRIC SHOCK.

All electrical connections and wiring MUST be installed by a qualified electrician.

Follow the National Electrical Code (NEC) and/or local codes and ordinances.

For personal safety, this Zoneline unit and case must be properly grounded.

Protective devices (fuses or circuit breakers) acceptable for Zoneline installations are specified on the nameplate of each unit.

Do not use an extension cord with this unit.

Aluminum building wiring may present special problems—consult a qualified electrician.

When the unit is not running there is still voltage to the electrical controls.

Disconnect the power to the unit before servicing by:

1.Removing the power cord (if it has one) from the wall receptacle.

OR

2.Removing the branch circuit fuses or turning the circuit breakers off at the panel.

Tape measure

WARNING: RISK OF ELECTRIC SHOCK. Can cause injury or death. This appliance must be properly grounded. Where a 2-prong wall outlet is encountered, it is your responsibility and obligation to have it replaced with a properly grounded 3-prong outlet.

10

Image 10
Contents Preparation WarrantyAir Filters Model # Serial #Safety Precautions Troubleshooting Controls-dip switchesControls-Dip Switches All Electric Heat Heat pump models onlyDuct Constant on FanOccupancy Sensor Field Supplied Freeze Sentinel Requires room air sensor kit-RAVRMSTemperature limiting during Cool mode Temperature Limiting Requires room air sensor kit-RAVRMSGEAppliances.com Room Air Sensor Requires room air sensor kit Ravrms Controls-terminal connectionsControls-Terminal Connections Also be connected to the remote thermostatMotion Sensor Obtained locally Central Desk ControlRemote Thermostat Door Sensor Obtained locallyVentilation Control Other features of your ZonelineOn/Off Switch About Heat Pumps on some modelsBase Pan Care and cleaningDrain Air FiltersInstallation Recommended branch circuit wire sizes For 230/208 Volt Cord Connections onlyAttach Conduit For 230/208 Volt Direct Connect Applications onlyRemove Junction BOX Cover Important Connection of a 265V AC productMake Wire Lead Connections Inside the Junction BOX Power Connection ChartModel Type Required AccessoriesZoneline Components Electronic ThermostatTypical Utility Closet and Dimensions Top ViewUtility Closet Connection Locations Option Air grille and access door/panelUnit-mounted filter with a field-supplied return Build and Install the Zoneline Base Platform 000 BTU 12,000 BTU 18,000 BTU Install the DrainsDuctwork 390 415 440 465 490 435 485 535Adjust all four leveling legs until the case is level Install and Connect the CaseInstall and Ground Unit to the Case Unit to the CaseMake Unit Electrical Connections Maximum Wiring Length for Thermostat Connection to the UnitConnect the TOP Duct Final Check Connect PowerServicing Unit is unplugged Before You Call For Service…Power failure Indoor airflow is restricted Air filter is dirtyNormal Operating Sounds Minute delayThings that are normal Compressor. You may also hear a fan noise stop and startGEAppliances.com Page What GE Will Not Cover Vertical Zoneline WarrantyFor The Period GE Will Replace Model numberConsumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design Studio

8500 Series specifications

The GE 8500 Series represents a remarkable advancement in the realm of industrial gas turbines, combining efficiency, reliability, and flexibility. Designed to meet the demands of current energy markets, this series of turbines is engineered for both baseload and peak-load applications, making it an ideal choice for operators seeking to optimize their energy production.

One of the standout features of the GE 8500 Series is its exceptional thermal efficiency. With a capability of achieving efficiency levels exceeding 60%, these turbines significantly reduce fuel consumption and lower greenhouse gas emissions. This feature not only makes them environmentally friendly but also helps operators reduce operational costs in the long run, positioning them favorably in a competitive energy landscape.

The GE 8500 Series incorporates advanced airfoil technologies that enhance performance. Featuring an innovative blade design, these turbines are capable of operating efficiently across a wide range of operating conditions. The materials used in the construction of the blades are engineered for durability, allowing them to withstand the harsh environments often encountered in power generation. This greatly extends the service life of the turbine and reduces downtime for maintenance.

Another important aspect of the GE 8500 Series is its adaptability. These turbines can utilize various fuels, including natural gas, hydrogen, and biofuels, offering flexibility to operators in terms of resource management. This feature allows utilities to adjust to changing fuel availability and price fluctuations, ensuring consistent energy generation.

The control and monitoring systems integrated into the GE 8500 Series are state-of-the-art, featuring advanced digital control technologies that provide real-time performance data. This allows operators to make informed decisions regarding maintenance and operational adjustments, ultimately enhancing the overall reliability of the power generation system.

In addition to these advancements, the GE 8500 Series is designed with a focus on reduced emissions without compromising performance. The turbines incorporate advanced combustion technologies that facilitate ultra-low emissions, aligning with the global movement toward cleaner energy solutions.

In conclusion, the GE 8500 Series is an exceptional line of gas turbines that combines high efficiency, flexibility, and low emissions. With advanced technologies and robust features, these turbines are positioned to meet the evolving needs of the energy sector while supporting the transition to a more sustainable future.