Napoleon Fireplaces GDS60-P B-VENT SPECIFICS - MODEL GS60, Chimney Installation, Combustion Air

Models: GDS60-N GS60-N GDS60-P GS60-P

1 24
Download 24 pages 48.79 Kb
Page 13
Image 13
B-VENT SPECIFICS - MODEL GS60

13

B-VENT SPECIFICS - MODEL GS60

CHIMNEY INSTALLATION

THREE TYPES OF

CHIMNEY SYSTEMS

MAY BE USED WITH

THIS STOVE:

FIGURES 29

INSTALLING 'B' VENT:

Follow the instructions of the 'B' vent manufacturer for chim- ney installation.

1.Remove the access plate. Remove and discard the air intake cover plate located directly behind the access plate.

2.Feed the 2 wires, supplied, through the 7" collar at the top of the unit; bring them out the air intake opening but behind the rear panel as shown.

Ensure that 2 female ends remain at the top. Re-secure the access plate.

3.Remove the spill switch bracket from the rear of the adapter. Unscrew the spill switch and discard the bracket. Attach the spill switch to the bracket supplied with the stove and secure onto the adapter.

4.Bring the wires through the lower hole in the adapter. To pass the wires through the hole more easily, temporarily tape the two terminals together.

5.With the spill switch opening aligned to the back of the stove, take hold of the adapter base and push the crimped edge into the stove flue collar.

6.Connect the upper wire terminals to the spill switch.

FIGURE 31

7.Disconnect the wire lead from terminal 3 on the valve and reconnect to the male end of the spill switch wire. Con- nect the female end of the spill switch wire to terminal 3 on the valve.

Leave all excess wire in an orderly manner.

For aesthetics, the adapter has been designed to ac- cept a standard matte black 7" stove pipe and the Na- poleon decorative brass band (standard with the GS-150KT). Both are available from your Napoleon dealer.

B-VENT MODEL GS60 ONLY

Attach the B-Vent label, shown below, in the control area of the appliance.

ATTACH THIS LABEL IN THE CONTROL AREA OF THE FIREPLACE.

THIS FIREPLACE HAS BEEN CONVERTED TO A ‘B’VENT MODEL.

ATTACHEZ CET ETIQUETTE DANS LA REGION DE CONTROLE DU FOYER.

CE FOYER A ETE CONVERTI A UN MODELE A SYSTEME D’EVACUATION ‘B’.

ws-385-160

COMBUSTION AIR

A chimney venting this stove shall not vent any solid fuel burning appliance.

Any stove needs air for safe operation and must be in- stalled in such a way that adequate combustion air is available.

FIGURE 30

W415-0158 / E / 02.19.04