Napoleon Fireplaces GS60-N, GS60-P, GDS60-P Lighting Instructions, To Turn Off Gas, Maintenance

Models: GDS60-N GS60-N GDS60-P GS60-P

1 24
Download 24 pages 48.79 Kb
Page 18
Image 18
LIGHTING INSTRUCTIONS

18

LIGHTING INSTRUCTIONS

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermo- couple has cooled. Allow approximately 60 seconds for the thermocouple to cool before attempting to re-light. When lighting and re-lighting, the gas knob cannot be turned from PILOT to OFF unless the knob is depressed.

1.STOP! Read the safety information on the operating label.

2.Turn off all electric power to the fireplace.

3.Turn the gas knob clockwiseTO TURN OFF GAS to off.

4.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor, STOP! Follow "B" on the op- erating label. If you don't smell gas go to the next step.

OL

 

 

 

N

O

H I

O

F

 

F

 

 

P

 

 

TO LI

TOLIP

 

 

5.Find pilot located in front of the back log.

6.Turn gas knob counter-clockwise MAINTENANCE to pilot.

7.Depress and hold the gas knob while lighting the pilot with the push button ignitor. Keep knob fully depressed for one minute, then release. If the pilot does not con- tinue to burn, repeat steps 3 through 6.

8.With the pilot lit, turn the gas knob counter-clockwise TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER to on.

9.If equipped with a remote ON-OFF switch, main burner may not come on when you turn the valve to ON. The remote switch must be in the ON position to ignite the burner.

10.Turn on all electric power to the fireplace.

TO TURN OFF GAS

1. Turn off all electric power to the fireplace if service is to

2. Push in gas control knob slightly and turn clock-

be performed.

wise

 

to off. Do not force.

 

MAINTENANCE

TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER

BEFORE SERVICING THE STOVE!

CAUTION: Label all wires prior to disconnection when serv- icing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing. This stove and its venting system should be inspected before use and at least annually by a qualified service per- son. The fireplace area must be kept clear and free of com- bustible materials, gasoline or other flammable vapours and liquids. The flow of combustion and ventilation air must not be obstructed.

1. In order to properly clean the burner and pilot assem- bly, remove the logs exposing both assemblies.

2. Keep the control compartment, logs, burner, air shut- ter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.

4. Check to see that the pilot flames are large enough to engulf the thermocouple and the thermopile on one leg and reaches toward the burner on the other leg.

5. Replace the cleaned logs.

6. Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5-10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer/dis- tributor.

7.Check that the door gasketing is not broken or miss- ing. Replace if necessary.

W415-0158 / E / 02.19.04