LOCATION & CLEARANCES

5

LOCATION & CLEARANCES

Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the stove.

Never obstruct the front opening of the stove.

GDS60 AND GS60

As long as clearance to combustibles is kept within the required distances, the most desirable and beneficial lo- cation for a Napoleon stove is in the centre of a building, thereby allowing the most efficient use of the heat created. The location of windows, doors and the traffic flow in the room where the stove is to be located should be consid- ered. If possible, you should choose a location where the vent will pass through the house without cutting a floor or roof joist.

MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES:

FIGURE 3

A. 6" B. 6" C. 2"*

NO ADDITIONAL FLOOR PROTECTION IS REQUIRED

MINIMUM 20" FROM STOVE TOP TO CEILING

6" TO SINGLE WALL CONNECTOR

1" TO DIRECT VENT AND B-VENT

*AT A DISTANCE OF 2" FROM THE WALL, ACCESS TO THE BLOWER SWITCH, ON-OFF SWITCH OR THE BLOWER POWER CORD MAY NOT BE PRACTICAL.

A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. Local codes or regulations may require different clearances.

Donotallowtheinsidelinertobunchuponhorizontal orverticalrunsandelbows. Keepitpulledtight.A 1-1/ 4"airgapallaroundbetweentheinnerlinerandouter stovepipeisrequiredforsafeoperation.Useafirestop when penetrating interior walls, floor or ceiling.

FIGURE 2 - SHOWN WITH OPTIONAL FRONT INSTALLED

NOTE: The total width of the stove is increased to 39" width with the optional side shelves attached.