Samsung UM18B1C2, UM26B1C2, UM27B1C3, AM27B1C13, AM27B1C07, AM26B1C13 Technical Specifications, Model

Page 24

Technical Specifications

 

 

MODEL

 

 

Indoor unit

Outdoor unit

 

Indoor unit

Outdoor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AM18B1C09

UM18B1C2

 

AM26B1C13

UM26B1C2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

2 Comp + 2 Room

 

 

2 Comp + 2 Room

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance

Capacity Cooling

Btu/h

 

A/B-Unit : 9000

 

 

A/B-Unit : 12500

 

Ratings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SEER

 

 

 

 

10.0

 

 

 

 

 

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Moisture Removal

Pts/h

 

3

 

 

 

-

 

 

4

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air FLOW(Cooling, HIGH)

CFM

 

255

 

 

-

 

 

300

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sound Rating-Outdoor

dB

 

-

 

 

 

57

 

 

-

 

 

 

60

 

 

 

 

 

 

 

 

 

Electrical

The number of operation

 

1 Unit operation

2 Unit operation

1 Unit operation

2 Unit operation

Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power source

 

 

208-230V~,60Hz

 

 

208-230V~,60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min.Ampacity

A

 

4.3

 

 

8.4

 

 

6.1

 

 

11.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Watts

W

 

990

 

 

1920

 

 

1360

 

2550

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigeration

Indoor unit

 

 

A-Unit

B-Unit

 

 

A-Unit

B-Unit

 

Lines

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connections

 

 

 

 

Flare

 

 

 

 

 

Flare

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liquid Line O. D.

mm(in)

 

 

 

6.35 (1/4)

 

 

 

 

 

6.35 (1/4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suction Line O.D.

mm(in)

 

 

 

9.52 (3/8)

 

 

 

 

 

12.70 (1/2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory Pre-charge

m(ft)

 

 

 

5.0 ( 16 12 )

 

 

 

 

 

5.0 ( 16 12 )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Line length

m(ft)

 

 

 

15.0 ( 49 14 )

 

 

 

 

 

15.0 ( 49 14 )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Height Difference

m(ft)

 

 

 

7.0 (23)

 

 

 

 

 

7.0 (23)

 

 

 

 

 

 

 

 

 

 

Dimensions

W X H X D

mm(in)

790 x 245 x 165

880 x 638 x 310

790 x 245 x 165

1000 x 790 x 310

(

1

1

1

1

1

1

(

1

1

1

1

1

1

& Weight

 

 

31 8 x 9

2

x 6 2 )

(34 2 x 258 x12

4 )

31 8 x 9

2

x 6 2 )

(39 2 x318 x 12

4 )

 

 

Net Weight

Ibs

 

17

 

 

132.3

 

 

17

 

 

152.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard rating conditions Cooling

 

Indoor

Outdoor

 

DB

WB

DB

WB

°F

80

67

95

75

°C

26.7

19.4

35.0

23.9

E-24

Image 24
Contents Installation Manual Manual DE Instrucciones Safety Precautions Contents View of the Unit Indoor UnitOutdoor Unit UM18B1C2 Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Installing the Remote Controller HolderUsing with the indoor unit Selecting with the Remote ControlWay Function To obtain anSelecting the Automatic Operating Mode Cooling Your Room Changing the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Vertically Adjusting the Air Flow Direction HorizontallySetting the On Timer To Cancel the On TimerSetting the Off Timer To Cancel the Off TimerSetting the Sleep Timer To Cancel the Sleep TimerOperating Recommendations TopicRecommendationTemperature and Humidity Ranges Mode Outdoor Temperature Indoor Temperature Indoor HumidityIf the air conditioner is used at... Then Cleaning Your Air Conditioner Have switched off the breaker used for the unitSolving Common Problems AUTO, CoolInstalling a Filter Option Technical Specifications ModelUnit operation Installation Manual Purging the Unit Deciding on Where to Install the Air Conditioner Indoor UnitUnit Piping length and the height26,000Btu/h 27,000Btu/h Air Conditioner and Accessories Accessories in the Indoor Unit CaseAccessories in the Outdoor Unit Case Fixing the Installation Plate Then follow StepsWall Window frame Purging the Unit Connecting the Assembly Cable Outdoor Unit Installing and Connecting the Indoor Unit Drain Hose To install the drain hose, proceed as followsInstalling and Connecting the Indoor Unit Assembly Piping PipeTorque Cutting/Extending the Piping Depth aConnecting the Cables to the Outdoor Unit UM18B1C2UM26B1C2 UM27B1C318/26 Auxiliary Circuit Breaker Electrical WorkChecking Correct Earthing Fixing the Unit in Position Connecting Up and Purging the Circuit Use Vacuum Pump as shown at the figureTo check for gas leaks on Then, using a leak detector Check Performing Leak TestsPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner Electronics

AM26B1C13, AM27B1C07, AM27B1C13, UM27B1C3, UM26B1C2 specifications

The Samsung AM27B1C07, UM26B1C2, AM26B1C13, AM27B1C13, and UM18B1C2 are a series of advanced memory devices that underline Samsung's commitment to providing high-performance solutions in the evolving landscape of electronics and computing. These products are characterized by their cutting-edge technologies, reliability, and efficiency, catering to various applications in consumer electronics and industrial use.

One of the main features of these series is their use of Samsung’s state-of-the-art NAND flash technology. This technology is designed to enhance data storage performance while minimizing power consumption, making these devices ideal for portable and battery-operated applications. The devices utilize 3D NAND architecture to increase storage density while ensuring superior durability and speed.

The AM27B1C07 and AM27B1C13 are particularly noted for their high sequential read and write speeds, making them suitable for tasks that require rapid data access, such as gaming and high-definition video processing. These memory solutions support advanced error correction codes (ECC) which ensure data integrity and reliability over time. They have also been optimized for lower latency, enhancing overall system responsiveness.

The UM26B1C2 and UM18B1C2 variants focus on delivering optimized bandwidth, catering well to the demands of modern applications including mobile devices, tablets, and laptops. With integrated power management features, these memory devices help extend battery life while maintaining high-performance levels during peak usage.

All models in this series are built to withstand demanding environments, boasting an extended temperature range that assures stable operation. This feature makes them highly suitable for industrial applications where conditions can fluctuate significantly.

Additionally, Samsung’s commitment to sustainability is evident in these memory solutions. They are designed with energy-efficient processes that not only enhance performance but also reduce the carbon footprint of their production.

Overall, the Samsung AM27B1C07, UM26B1C2, AM26B1C13, AM27B1C13, and UM18B1C2 integrate advanced technologies and features that address the needs of various markets, including consumer electronics, automotive, and industrial sectors. Their blend of high speed, efficiency, and reliability makes them an attractive choice for manufacturers looking to enhance their product offerings with cutting-edge memory solutions.