Samsung AM27B1C07, UM18B1C2 Deciding on Where to Install the Air Conditioner, Indoor Unit

Page 28

PREPARING THE INSTALLATION

Deciding on Where to Install the Air Conditioner

When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account.

General

Do NOT install the air conditioner in a location where it will come into contact with the following elements:

Combustible gases

Saline air

Machine oil

Sulphide gas

Special environmental conditions

If you must install the unit in such conditions, first consult your dealer.

Indoor Unit

There must be no obstacles near the air inlet and outlet.

Install the indoor unit on a surface that can support its weight.

Choose a position that enables the piping and cables to be easily connected to the outdoor unit and the recommended length of 5m (16ft. 5in) to be respected (15m (49ft. 3in) maximum).

Leave enough clearance beneath the indoor unit to enable the filters to be removed without hindrance.

Maintain sufficient clearance around the indoor unit, as indicated in the diagram on the page opposite.

Make sure that the water dripping from the drain hose runs away correctly and safely.

Outdoor Unit

The outdoor unit must NEVER be placed on its side or upside down, as the compressor lubrication oil will run into the cooling circuit and seriously damage the unit.

Choose a location that is dry and sunny, but not exposed to direct sunlight or strong winds.

Do not block any passageways or thoroughfares.

Choose a location where the noise of the air conditioner when running and the discharged air do not disturb any neighbours.

Choose a position that enables the piping and cables to be easily connected to the indoor unit and the recommended length of 5m (16ft. 5in) to be respected (15m (49ft. 3in) maximum).

Install the outdoor unit on a flat, stable surface that can support its weight and does not generate any unnecessary noise and vibration.

Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of the unit.

Maintain sufficient clearance around the outdoor unit, as indicated in the diagram on the page opposite.

If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position; the maximum height is 7m (23ft).

Make sure that the water dripping from the drain hose runs away correctly and safely.

CAUTION

You have just purchased a split-type room air conditioner and it has been installed by your installation specialist.

This device must be installed according to the national electrical rules.

E-28

Image 28
Contents Installation Manual Manual DE Instrucciones Safety Precautions Contents View of the Unit Indoor UnitOutdoor Unit UM18B1C2 Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Installing the Remote Controller HolderUsing with the indoor unit Selecting with the Remote ControlWay Function To obtain anSelecting the Automatic Operating Mode Cooling Your Room Changing the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Vertically Adjusting the Air Flow Direction HorizontallySetting the On Timer To Cancel the On TimerSetting the Off Timer To Cancel the Off TimerSetting the Sleep Timer To Cancel the Sleep TimerOperating Recommendations TopicRecommendationMode Outdoor Temperature Indoor Temperature Indoor Humidity Temperature and Humidity RangesIf the air conditioner is used at... Then Cleaning Your Air Conditioner Have switched off the breaker used for the unitSolving Common Problems AUTO, CoolInstalling a Filter Option Technical Specifications ModelUnit operation Installation Manual Purging the Unit Deciding on Where to Install the Air Conditioner Indoor UnitUnit Piping length and the height26,000Btu/h 27,000Btu/h Accessories in the Indoor Unit Case Air Conditioner and AccessoriesAccessories in the Outdoor Unit Case Then follow Steps Fixing the Installation PlateWall Window frame Purging the Unit Connecting the Assembly Cable Outdoor Unit Installing and Connecting the Indoor Unit Drain Hose To install the drain hose, proceed as followsPipe Installing and Connecting the Indoor Unit Assembly PipingTorque Cutting/Extending the Piping Depth aConnecting the Cables to the Outdoor Unit UM18B1C2UM26B1C2 UM27B1C318/26 Auxiliary Circuit Breaker Electrical WorkChecking Correct Earthing Fixing the Unit in Position Connecting Up and Purging the Circuit Use Vacuum Pump as shown at the figureTo check for gas leaks on Then, using a leak detector Check Performing Leak TestsPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner Electronics

AM26B1C13, AM27B1C07, AM27B1C13, UM27B1C3, UM26B1C2 specifications

The Samsung AM27B1C07, UM26B1C2, AM26B1C13, AM27B1C13, and UM18B1C2 are a series of advanced memory devices that underline Samsung's commitment to providing high-performance solutions in the evolving landscape of electronics and computing. These products are characterized by their cutting-edge technologies, reliability, and efficiency, catering to various applications in consumer electronics and industrial use.

One of the main features of these series is their use of Samsung’s state-of-the-art NAND flash technology. This technology is designed to enhance data storage performance while minimizing power consumption, making these devices ideal for portable and battery-operated applications. The devices utilize 3D NAND architecture to increase storage density while ensuring superior durability and speed.

The AM27B1C07 and AM27B1C13 are particularly noted for their high sequential read and write speeds, making them suitable for tasks that require rapid data access, such as gaming and high-definition video processing. These memory solutions support advanced error correction codes (ECC) which ensure data integrity and reliability over time. They have also been optimized for lower latency, enhancing overall system responsiveness.

The UM26B1C2 and UM18B1C2 variants focus on delivering optimized bandwidth, catering well to the demands of modern applications including mobile devices, tablets, and laptops. With integrated power management features, these memory devices help extend battery life while maintaining high-performance levels during peak usage.

All models in this series are built to withstand demanding environments, boasting an extended temperature range that assures stable operation. This feature makes them highly suitable for industrial applications where conditions can fluctuate significantly.

Additionally, Samsung’s commitment to sustainability is evident in these memory solutions. They are designed with energy-efficient processes that not only enhance performance but also reduce the carbon footprint of their production.

Overall, the Samsung AM27B1C07, UM26B1C2, AM26B1C13, AM27B1C13, and UM18B1C2 integrate advanced technologies and features that address the needs of various markets, including consumer electronics, automotive, and industrial sectors. Their blend of high speed, efficiency, and reliability makes them an attractive choice for manufacturers looking to enhance their product offerings with cutting-edge memory solutions.