Pelco C2410M-J manual Adjustments, VERTICAL PHASE 24 VAC OPERATION ONLY

Page 8
Adjustments

Adjustments

The camera is set up at the factory and normally requires no adjustments. Sometimes, however, adjustments may be necessary.

1.Remove the dome and trim ring using the supplied 1/8-inch hollow screwdriver bit.

2.Adjust the vertical phase, focus, or switch settings (refer to the following procedures).

3.Replace the dome and trim ring.

VERTICAL PHASE (24 VAC OPERATION ONLY)

Adjustment is required if there is vertical roll when switching between two cameras.

1.Reverse the 24 VAC connections on one camera. If both cameras are connected to the same transformer, this should solve the problem.

2.If reversing the connections does not solve the problem, or if cameras are connected to different transformers, turn the adjustment screw on one camera (while switching as rapidly as possible between the two camera views) until the switching is clean and there is no vertical roll. If more than two cameras are out of synchronization with each other, choose one camera and synchronize all others to it.

VERTICAL

PHASE

ADJUSTMENT

SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITHOUT AUTO IRIS

Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation (factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions, where there are no bright spots that darken other picture details. Manual backlight compensation is used in fixed lighting conditions to optimize the picture detail when there are bright spots.

ALC/ELC switch:

Always ELC

Y/DC switch:

Not used

Auto backlight compensation:

BLC switch OFF

 

 

ABL switch ON

Manual backlight compensation:

BLC switch ON

 

 

ABL switch OFF

FACTORY SETTINGS

ALC

Y

BLC

ABL

ON

 

 

 

 

 

 

 

 

 

 

 

 

USED

 

 

 

 

 

OFF

 

 

 

NOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELC

DC

OFF

OFF

VERTICAL PHASE (24 VAC OPERATION ONLY) = SWITCH POSITION

8

C2410M-J (2/08)

Image 8
Contents 150 Series Camclosure Integrated Camera System C2410M-J2/08In-CeilingMount I N S T A L L A T I O NContents Important Safety Instructions Regulatory Notices Radio and Television InterferenceInstallation INSTALL BACK BOXDescription MOUNTING DIRECTLY TO A WALL OR CEILINGINSTALL CAMERA MOUNTING TO CEILING TILEINSTALL DOME AND TRIM RING Turn on power to the camera and monitorNOTE The screws are installed at an angle Proper camera orientationAdjustments VERTICAL PHASE 24 VAC OPERATION ONLYELECTRICAL SpecificationsGENERAL RETURNS PRODUCT WARRANTY AND RETURN INFORMATIONWARRANTY REVISION HISTORY Manual #Date CommentsWorldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & CanadaTel 800/289-9100 Fax 800/289-9150 International Tel 1-559/292-1981 Fax 1-559/348-1120