SkyLink Emergency Dialer Dial-Alert, AD-433S manual Advanced Programming, Program the Calling Time

Page 9

ADVANCED PROGRAMMING

PROGRAM THE CALLING TIME

The calling time is the amount of time the phone will ring until the call is dis- contected. If the phone is not picked up within this period of time, the dialer will either call again, (depends on the redial count), or advance to the next phone number. The calling time is currently set at 60 seconds.

How to program the calling time.

1. Press the [L] key, the display will show “ L ”

2. Press the [1] key, the diplay will show “ L 1 1 ”, the last digit, “ 1 ”, is the setting of the call time, (in this example, it is currently 30 seconds, as per chart below). To keep this setting, press the [L] key.

3.To change the calling time, press either 1, 2, 3, 4 or 5 when the diplay

shows “ L 1 1 ” (refer to the chart below)

1

=

30 seconds

2

=

45 seconds

3

=

60 seconds

4

=

75 seconds

5

=

90 seconds

If the display shows “ L 1

3 ”, the phone will ring for 60 seconds before

the call is disconnected.

 

 

PROGRAMMING A PAUSE PERIOD

When storing a phone number, you are able to insert a pause period between any digits of the phone number or after the phone number and before the numeric message (for pagers).

To set the pause period for pagers numeric message

1. Press the [L] key, the display will show “ L ”

2. Press the [2] key, the display will show “ L 2 5 ”, the last digit, “ 5 ”, is the setting of the pause period (in this example, it is currently set at 5 seconds), to keep this setting, press the [L] key.

3. To change the pause period, between 1 to 9 seconds, press ( 1 - 9 ) on the keypad while the display shows “ L 2 5 ”. If the number 9 is entered, the pause period between the number dialed and the numeric message is 9 seconds.

Program pause period between phone number and numeric message

Press the [R/P] key to insert a pause period between the telephone number and the numeric information you want to send. The pause period is the time you have to wait after the connection has been made to the paging company

15

ADVANCED PROGRAMMING

and before you can enter the numeric information (i.e. phone number). The display will show a "P" if a pause period is entered. This pause period is factory set at 5 seconds but can be changed from 1 - 9 seconds. You may also insert multiple pause periods to suit your application. Call the paging company to determine how long the pause period should be.

To insert a pause period in a telephone number

The length of the pause period [L*] can be programmed as shown.

1. Press the [L] key, the display will show "L".

2. Press the [ * ] key, the display will show "L* 3", the last digit, "3", is the setting of the pause period, (in this example, it is currently set to 3 seconds, as per chart below). To keep this setting, press the [L] key.

3.To change the pause period, press either 1, 2.....or 9 when the display shows "L* 3".

1

=

1 second

2

=

2 seconds

3

=

3 seconds

4

=

4 seconds

5

=

5 seconds

6

=

6 seconds

7

=

7 seconds

8

=

8 seconds

9

=

9 seconds

When programming a telephone number to the dialer, (see STORING TELE- PHONE NUMBERS), a pause period may be added between any digits of a phone number. By using the " * " key on the keypad, a pause period will be entered. The pause period will be anywhere between 1-9 seconds, (see the beginning of this section to set the length of the pause period). Example, if you wanted a pause between the third and forth number, the sequence would go as follows, 568*2095. If the pause period was set at five seconds, there would be a five second delay between the 8 and the 2.

SET THE TYPE OF PHONE SYSTEM

This dialer supports both regular telephone and PABX phone systems. Selection can be made using the function key. The dialer is currently set for regular phones.

To select the phone system:

1. Press the [L] key, display will show an “L”.

2. Press the [3] key, display will show “L 3 1 ”, the last digit (1) means the dialer is set for regular phone.

3.To change the setting of the dialer to PABX systems, press [2].

The display will show “ L 3 2 ” and the system is now set to PABX system.

16

Image 9
Contents Emergency Dialer Emergency Dialer Package Contents Table of ContentsHow to use the template InstallationInstalling the DIAL-ALERT AD-433S OverviewTone/Pulse Switch Switch SettingStandard Programming Lights and SoundsStoring Telephone Numbers Playback PRE-RECORDED MessageActivate the DIAL-ALERT with the Panic Button on the Keypad Delete a Telephone Number from MemoryProgram the Calling Time Advanced ProgrammingProgramming a Pause Period SET the Type of Phone SystemProgram the ID Code of a Transmitter Delay Dialing Entry / Exit ModeDelete Programmed TRANSMITTERS/SENSORS/SECURITY Systems To ARM/DISARM the DialerTo set the dialing delay Entering a premises using the delay dialingDial Sequence Setting To program the Dial Sequence SettingConnect the DIAL-ALERT with Your Existing Alarm System Additional Accessories Battery MaintenanceDial-Alert Battery To replace the dialer backup batteryTemperature Sensor TS-433 Silent Alarm SW-433Security Control Panel SC-001 Vibration Sensor VS-433