OVERVIEW

Automatically call for help when emergency

The AD-433S Dial-Alertdials as many as 9 pre-programmed telephone numbers and sends a personalized pre-recorded message. Each telephone number can be dialed up to 9 times and the person receiving the emergency message can confirm receipt of that message by pressing the "#" key on their telephone. A pre-recorded message, maximum 40 seconds in length will be played notifying the person being called of the emergency.

The Dial-Alertworks in conjunction with Skylink's Security Systems (SC-5, SC-10, SC-100 series, SC-200 series) and all the Skylink Sensors / Transmitters. When the alarm sounds on the control panel on any of our security systems, the Dial-Alertwill be activated .

The Dial-Alertis activated when:

1.The red panic button [O] on the keypad of the Dial-Alertis pressed

2.The button is pressed on the panic transmitter (PT-434*, sold separately)

3.The red panic button [O] on the keypad of our security system (SC-100) is pressed *

4.The red button on the keychain transmitter (4B-434)* is pressed

5.The security system SC-100/SC-200 is activated by any programmed sensors (i.e. door/window sensor, motion sensor, etc.)

*The security systems, keychain transmitters and sensors must first be programmed to communicate with the Dial-Alert.

This user's instructions is divided into 4 sections in order to assist in the installation and programming of your Dial-Alert.

1.Installation

2.Lights and Sounds

3.Standard Programming

-Program the time clock

-Record a message

-Playback of pre-recorded message

-Storing telephone numbers in memory for

-emergency voice message only

-both emergency voice message and numeric pager information

-numeric pager information only

-Delete a telephone number from memory

-Modify a telephone number, the redial count and repeat times of a phone number

4.Advanced Programming

-Programming the calling time

-Programming the pause period for pager access and telephone numbers

-Select the phone system (regular or PABX phone systems)

-Program transmitters / accessories to activate dialer

-Erase programmed transmitters / accessories

-To arm / disarm the dialer

-Dialing delay

- Universal Dial Tone

5

 

INSTALLATION

The Dial-Alertis installed using the screws provided. We have also included double sided tape, to use for temporary installation while you are positioning the dialer. Once the dialer is positioned correctly, install it permanently with screws. We have also included wall anchors and a template to help position the screws correctly.

How to use the template:

1.Cut the template in correct position

2.Screw part way into the surface where the holes are marked

4.Unscrew the screws and remove the template

5.Screw the component in place where you started the screws

INSTALLING THE DIAL-ALERT (AD-433S)

Position the dialer beside a telephone or near any phone line and within access of an electrical outlet. However, it is recommended that you hide the dialer for security purposes. The dialer runs on regular electrical current. It also contains a 9 volt backup battery in case power is interrupted for any reason. A phone line must be connected to the dialer in order for the dialer to work. Connect the phone lines and AC adapter as shown.

12V DC

ACADAPTER

OPTIONALLINEINPUTFOR

PHONE ANSWERINGMACHINE/TELEPHONE

TELLINEIN

LINE

Note: The optional line input is intended for answering machine, tele- phone etc. The device connected to the dialer will be disconnected when the dialer is activated. Therefore it will not affect the operation of the dialer.

There are 3 ways to attach the Dial-Alerton the wall:

1.Using double sided tape for temporary use.

2.Hanging it from the two keyholes on two stationary screws.

3.Screwing the back onto the wall with four screws.

To mount the Dial-Alert:

1. Open the case.

a)Press the two tabs on top of the dialer.

b) Pull open the front.

6

Image 4
Contents Emergency Dialer Emergency Dialer Table of Contents Package ContentsInstallation How to use the templateInstalling the DIAL-ALERT AD-433S OverviewSwitch Setting Tone/Pulse SwitchLights and Sounds Standard ProgrammingPlayback PRE-RECORDED Message Storing Telephone NumbersDelete a Telephone Number from Memory Activate the DIAL-ALERT with the Panic Button on the KeypadAdvanced Programming Program the Calling TimeProgramming a Pause Period SET the Type of Phone SystemDelay Dialing Entry / Exit Mode Program the ID Code of a TransmitterDelete Programmed TRANSMITTERS/SENSORS/SECURITY Systems To ARM/DISARM the DialerEntering a premises using the delay dialing To set the dialing delayDial Sequence Setting To program the Dial Sequence SettingConnect the DIAL-ALERT with Your Existing Alarm System Battery Maintenance Additional AccessoriesDial-Alert Battery To replace the dialer backup batterySilent Alarm SW-433 Temperature Sensor TS-433Security Control Panel SC-001 Vibration Sensor VS-433