Rinnai RHFE-431FA installation manual Location / Clearances, Flue Sizes

Page 20

LOCATION / CLEARANCES

When positioning the heater the main points governing the location are:

1.Flueing

2.Warm air distribution

This heater is not designed to be build in.

The flue is not designed to be positioned under floors, or below the level of the heater.

Flue

Terminal

Flue

Terminal

The flue terminal should be positioned away from flammable materials.

LP GAS

Flue Terminal

Do not flue into natural draught flues or fireplaces, this unit can only be used with one of the five types of Rinnai flue kits. Do not flue unit into other rooms. Flue terminal must be outside.

Flue may be positioned directly under opening windows, with a minimum clearance of 9" (230mm).

FLUE SIZES:

5 Flue lengths are available.

S flue walls 3"4 1/2" (75115mm)

Aflue walls 4 1/2"9 1/2" (115240mm)

Bflue walls 9 1/2"15 3/4" (240400mm)

Cflue walls 15 3/4"23 5/8" (400600mm)

Dflue walls 23 5/8"31 1/2" (600800mm)

– 18 –

Image 20
Contents RHFE-431FAⅢ Table of Contents Features of the RHFE-431FA Units Safety DevicesGeneral Information Important Points / Usage and Installation Musts Included in CartonPage Dimensions Specifications SpecificationsAIR Supply Safety Points Gasoline Getting to Know Your NEW RHFE-431FA ALL Buttons Beep When Operated Control PanelCUT-AWAY Diagram Page Installation Instructions GAS Connection Wall Mounting Brackets Flue Manifold PositionSecure Heater to Wall Vent Termination Clearances WindowordoorthatmaybeopenedLocation / Clearances Flue SizesFIT Back Covers Sides only Standard Installation of Flue ManifoldSnow Areas Sleeve and Manifold Installation Method for Standard WallsProvided to compensate for weather board angle Locking Clamp Screw Clamp and Insulation Fitting UnitAIR Inlet Hose Instruct Customer on USE of Heater Operating Instructions Temperature Control IgnitionRoom Temperature Display Operating PrecautionsTo Turn Unit OFF Economy ButtonRequired Distance from Flammables UsageUsage Location Emergency Procedures Daily Inspection and MaintenanceInstallation of Unit When Using for the First TimeChild Safety Lock Sensible Temperature ControlBefore the Cold Season Begins AIR Flow ControlCare of Air Filter Adding Water to HumidifierCare of Unit Exterior Page Testing Unit Fault-Failure ProcedurePRE-SERVICE Check At IgnitionDuring Combustion Other PointsTrouble Shooting Smellof gas NoisyignitionMaintenance / Service Maintenance SuggestionsCode Color Warranty Information Consumer SupportHeat Exchanger Year of Failure Allowance Schematic Diagram Page Page Page Page Parts List Page Page Page Part Name QTY Remarks Rank Parts Name Parts no QTY Remarks Vent KIT RHFE-431FA Names and Numbers of Parts RHFE-431FA Installing AN Extension KIT MODELRHFE-431FAHow to use the bent pipe How to connect exhaust pipesHow to connect air intake hose Maximum extendable length To prevent water condensationQualified Installing Agency GAS Pressure Setting Procedure Technical DataGAS Conversion Specifications Page 431F-1700×1700

RHFE-431FA specifications

The Rinnai RHFE-431FA is an advanced heating appliance designed to provide efficient warmth and comfort in residential spaces. With its sleek design and powerful performance, this model is a top choice for energy-conscious consumers seeking both functionality and aesthetics.

One of the standout features of the RHFE-431FA is its high heating efficiency, which helps reduce energy costs while ensuring a consistent and comfortable indoor climate. It operates using advanced gas technology, providing instant heat without the need for a cumbersome heating system. This unit is capable of delivering up to 4.2 kW of heating power, making it suitable for a variety of room sizes.

The unit's compact size and wall-mounted design allow for flexible installation options, blending seamlessly into any decor. The stylish front panel adds a modern touch while maintaining an unobtrusive presence. Additionally, the RHFE-431FA is available in multiple color options, ensuring that homeowners can choose a finish that best matches their interior design.

Equipped with Rinnai's advanced convection heating technology, the RHFE-431FA generates warmth that rises and circulates throughout the room efficiently. This method ensures that the heat is evenly distributed, eliminating cold spots and providing a comfortable living environment. The built-in fan helps to expedite heat distribution, making the unit effective in both small and larger areas.

The intelligent control system of the RHFE-431FA includes a user-friendly digital display, allowing for easy temperature adjustments and operational settings. The unit can be programmed to maintain specific temperatures, promoting energy savings when the space is unoccupied. Additionally, the unit features a child lock mechanism for added safety, making it an excellent choice for families.

Rinnai places a strong emphasis on safety, and the RHFE-431FA is no exception. This model is designed with multiple safety features, including an automatic shut-off function, ensuring peace of mind for users. Its silent operation also makes it a perfect addition to bedrooms or quiet spaces.

In summary, the Rinnai RHFE-431FA is a versatile and efficient heating solution that combines modern design, advanced technology, and safety features. Whether for a cozy family room, a bedroom, or any other space, this model promises to deliver comfort and warmth while being mindful of energy consumption.