What will Rinnai do?

Rinnai will repair any part or component that is defective in materials or workmanship as set forth as follows. All repair parts must be genuine Rinnai parts. All repairs or replacements must be performed by an individual or servicing company that has been authorized by Rinnai. Rinnai will pay reasonable labor charges associated with the repair or replacement of any part or component.

Replacement of the product may be authorized by Rinnai only. Rinnai does not authorize any person or company to assume for it any obligation or liability in connection with the replacement of a product. If Rinnai determines that repair of a product is not possible, Rinnai will replace the product with a comparable product, at Rinnai’s discretion.

*If the Heat Exchanger fails due to a defect in material or workmanship within the sixth (6) through the tenth (10) year from the date of purchase, Rinnai will make the following allowances toward the purchase of a replacement Heat Exchanger:

Heat Exchanger

Year of Failure

Allowance

 

 

6

50%

 

 

7

40%

 

 

8

30%

 

 

9

20%

 

 

10

10%

 

 

How do I get service?

You must contact a qualified/authorized service provider for the repair of a product under this Warranty. For the name of a qualified/authorized service provider please contact your place of purchase, visit the Rinnai website (www.rinnai.us), call Rinnai at 1-800-621-9419 or write to Rinnai at 103 International Drive, Peachtree City, Georgia 30269.

Proof of purchase is required to obtain warranty service. You may show proof of purchase with a dated sales receipt, or by registering within 30 days of purchasing the product. To register your appliance, please visit www.rinnairegistration.com. For those without internet access, please call 1-866-RINNAI1 (746-6241). Receipt of Registration by Rinnai will constitute proof-of-purchase for this product. However, Registration is not necessary in order to validate this Warranty.

What is not covered?

This Warranty does not cover any failures or operating difficulties due to accident, abuse, misuse, alteration, misapplication, force majeure, improper installation, improper conversion*, improper maintenance or service, or for any other causes other than defects in materials or workmanship. This Warranty does not apply to any product whose serial number or manufacture date has been defaced.

* Improper conversion includes conversions for inventory adjustment.

Rinnai is not liable for any special, incidental, indirect or consequential damages that may arise, including damage to person or property, loss of use, or inconvenience. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.

Limitation on implied warranties

Any implied warranties of merchantability and fitness arising under state law are limited in duration to the period of coverage provided by this limited Warranty, unless the period provided by state law is less. Some states do not allow limitations on how long an implied Warranty lasts, so the above limitation may not apply to you.

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

– 38 –

Image 40
Contents RHFE-431FAⅢ Table of Contents Features of the RHFE-431FA Units Safety DevicesGeneral Information Important Points / Usage and Installation Musts Included in CartonPage Dimensions Specifications SpecificationsAIR Supply Safety Points Gasoline Getting to Know Your NEW RHFE-431FA ALL Buttons Beep When Operated Control PanelCUT-AWAY Diagram Page Installation Instructions GAS Connection Secure Heater to Wall Flue Manifold PositionWall Mounting Brackets Vent Termination Clearances WindowordoorthatmaybeopenedLocation / Clearances Flue SizesSnow Areas Standard Installation of Flue ManifoldFIT Back Covers Sides only Sleeve and Manifold Installation Method for Standard WallsProvided to compensate for weather board angle AIR Inlet Hose Fitting UnitLocking Clamp Screw Clamp and Insulation Instruct Customer on USE of Heater Operating Instructions Temperature Control IgnitionRoom Temperature Display Operating PrecautionsTo Turn Unit OFF Economy ButtonUsage Location UsageRequired Distance from Flammables Emergency Procedures Daily Inspection and MaintenanceInstallation of Unit When Using for the First TimeChild Safety Lock Sensible Temperature ControlBefore the Cold Season Begins AIR Flow ControlCare of Unit Exterior Adding Water to HumidifierCare of Air Filter Page Testing Unit Fault-Failure ProcedurePRE-SERVICE Check At IgnitionDuring Combustion Other PointsTrouble Shooting Smellof gas NoisyignitionMaintenance / Service Maintenance SuggestionsCode Color Warranty Information Consumer SupportHeat Exchanger Year of Failure Allowance Schematic Diagram Page Page Page Page Parts List Page Page Page Part Name QTY Remarks Rank Parts Name Parts no QTY Remarks Vent KIT RHFE-431FA Names and Numbers of Parts RHFE-431FA Installing AN Extension KIT MODELRHFE-431FAHow to connect air intake hose How to connect exhaust pipesHow to use the bent pipe Maximum extendable length To prevent water condensationQualified Installing Agency GAS Conversion Specifications Technical DataGAS Pressure Setting Procedure Page 431F-1700×1700

RHFE-431FA specifications

The Rinnai RHFE-431FA is an advanced heating appliance designed to provide efficient warmth and comfort in residential spaces. With its sleek design and powerful performance, this model is a top choice for energy-conscious consumers seeking both functionality and aesthetics.

One of the standout features of the RHFE-431FA is its high heating efficiency, which helps reduce energy costs while ensuring a consistent and comfortable indoor climate. It operates using advanced gas technology, providing instant heat without the need for a cumbersome heating system. This unit is capable of delivering up to 4.2 kW of heating power, making it suitable for a variety of room sizes.

The unit's compact size and wall-mounted design allow for flexible installation options, blending seamlessly into any decor. The stylish front panel adds a modern touch while maintaining an unobtrusive presence. Additionally, the RHFE-431FA is available in multiple color options, ensuring that homeowners can choose a finish that best matches their interior design.

Equipped with Rinnai's advanced convection heating technology, the RHFE-431FA generates warmth that rises and circulates throughout the room efficiently. This method ensures that the heat is evenly distributed, eliminating cold spots and providing a comfortable living environment. The built-in fan helps to expedite heat distribution, making the unit effective in both small and larger areas.

The intelligent control system of the RHFE-431FA includes a user-friendly digital display, allowing for easy temperature adjustments and operational settings. The unit can be programmed to maintain specific temperatures, promoting energy savings when the space is unoccupied. Additionally, the unit features a child lock mechanism for added safety, making it an excellent choice for families.

Rinnai places a strong emphasis on safety, and the RHFE-431FA is no exception. This model is designed with multiple safety features, including an automatic shut-off function, ensuring peace of mind for users. Its silent operation also makes it a perfect addition to bedrooms or quiet spaces.

In summary, the Rinnai RHFE-431FA is a versatile and efficient heating solution that combines modern design, advanced technology, and safety features. Whether for a cozy family room, a bedroom, or any other space, this model promises to deliver comfort and warmth while being mindful of energy consumption.