Rinnai RHFE-431FA installation manual Operating Instructions

Page 26

OPERATING INSTRUCTION LABEL

ENERGYSAVER RHFE-431FA

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

STOP! Read the safety information above on this label.

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the appliance via the ON/OFF button on the control panel. Locate manual gas valve to be found on back side of heater.

3.Turn Manual valve clockwise to the full OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety information above on this label. If you don't smell gas go to next step.

5.Turn Manual gas valve to the full on position.

6.Turn on all electric power to the appliance via ON/OFF button.

7.Set the thermostat to desired setting.

8.Burner is lit when indicator lamp “ON” turns red.

9.“ON” indicator flashes when burner fails to ignite.

10.If the appliance will not operate, follow the instruction “TO turn off gas to appliance” and call your service technician or gas supplier. See manual for additional information.

BACK SIDE OF HEATER

MANUAL GAS VALVE OPEN CLOSED

Thermostat

Lamps

Thermostat

Economy

Lamp

On/Off

Lamp

On/Off

Economy Button

Button

TO TURN OFF GAS TO APPLIANCE

1.Turn off electric power to the appliance using the ON/OFF button located on the control panel.

2.Locate manual valve on back side of unit.

3.Turn manual valve clockwise to the full OFF position.

NOTE: The fan will continue to operate until the appliance is cool, do not turn the appliance off by unplugging it from the wall.

Keep burner and control compartment clean. See installation and operating instructions accompanying heater.

– 24 –

Image 26
Contents RHFE-431FAⅢ Table of Contents Features of the RHFE-431FA Units Safety DevicesGeneral Information Important Points / Usage and Installation Musts Included in CartonPage Dimensions Specifications SpecificationsAIR Supply Safety Points Gasoline Getting to Know Your NEW RHFE-431FA ALL Buttons Beep When Operated Control PanelCUT-AWAY Diagram Page Installation Instructions GAS Connection Wall Mounting Brackets Flue Manifold PositionSecure Heater to Wall Vent Termination Clearances WindowordoorthatmaybeopenedLocation / Clearances Flue SizesFIT Back Covers Sides only Standard Installation of Flue ManifoldSnow Areas Sleeve and Manifold Installation Method for Standard WallsProvided to compensate for weather board angle Locking Clamp Screw Clamp and Insulation Fitting UnitAIR Inlet Hose Instruct Customer on USE of Heater Operating Instructions Temperature Control IgnitionTo Turn Unit OFF Room Temperature DisplayOperating Precautions Economy ButtonRequired Distance from Flammables UsageUsage Location Installation of Unit Emergency ProceduresDaily Inspection and Maintenance When Using for the First TimeBefore the Cold Season Begins Child Safety LockSensible Temperature Control AIR Flow ControlCare of Air Filter Adding Water to HumidifierCare of Unit Exterior Page Testing Unit Fault-Failure ProcedureDuring Combustion PRE-SERVICE CheckAt Ignition Other PointsTrouble Shooting Smellof gas NoisyignitionMaintenance / Service Maintenance SuggestionsCode Color Warranty Information Consumer SupportHeat Exchanger Year of Failure Allowance Schematic Diagram Page Page Page Page Parts List Page Page Page Part Name QTY Remarks Rank Parts Name Parts no QTY Remarks Vent KIT RHFE-431FA Names and Numbers of Parts RHFE-431FA Installing AN Extension KIT MODELRHFE-431FAHow to use the bent pipe How to connect exhaust pipesHow to connect air intake hose Maximum extendable length To prevent water condensationQualified Installing Agency GAS Pressure Setting Procedure Technical DataGAS Conversion Specifications Page 431F-1700×1700

RHFE-431FA specifications

The Rinnai RHFE-431FA is an advanced heating appliance designed to provide efficient warmth and comfort in residential spaces. With its sleek design and powerful performance, this model is a top choice for energy-conscious consumers seeking both functionality and aesthetics.

One of the standout features of the RHFE-431FA is its high heating efficiency, which helps reduce energy costs while ensuring a consistent and comfortable indoor climate. It operates using advanced gas technology, providing instant heat without the need for a cumbersome heating system. This unit is capable of delivering up to 4.2 kW of heating power, making it suitable for a variety of room sizes.

The unit's compact size and wall-mounted design allow for flexible installation options, blending seamlessly into any decor. The stylish front panel adds a modern touch while maintaining an unobtrusive presence. Additionally, the RHFE-431FA is available in multiple color options, ensuring that homeowners can choose a finish that best matches their interior design.

Equipped with Rinnai's advanced convection heating technology, the RHFE-431FA generates warmth that rises and circulates throughout the room efficiently. This method ensures that the heat is evenly distributed, eliminating cold spots and providing a comfortable living environment. The built-in fan helps to expedite heat distribution, making the unit effective in both small and larger areas.

The intelligent control system of the RHFE-431FA includes a user-friendly digital display, allowing for easy temperature adjustments and operational settings. The unit can be programmed to maintain specific temperatures, promoting energy savings when the space is unoccupied. Additionally, the unit features a child lock mechanism for added safety, making it an excellent choice for families.

Rinnai places a strong emphasis on safety, and the RHFE-431FA is no exception. This model is designed with multiple safety features, including an automatic shut-off function, ensuring peace of mind for users. Its silent operation also makes it a perfect addition to bedrooms or quiet spaces.

In summary, the Rinnai RHFE-431FA is a versatile and efficient heating solution that combines modern design, advanced technology, and safety features. Whether for a cozy family room, a bedroom, or any other space, this model promises to deliver comfort and warmth while being mindful of energy consumption.