Only properly trained and qualified installers should install this appliance. The warranty may be voided due to improper installation or installation by a non-qualified installer.

Rinnai highly recommends all installers attend a product knowledge class.

For information on a Rinnai Training Course or for questions on installation call 1-800-621-9419.

V53i

REU-VB2020FFU-US

V53e

REU-VAM1620W-US

The V53i and V53e are certified for installation in manufactured (mobile) homes.

General Instructions

Do not use substitute materials.

Use only parts certified with the appliance.

This appliance must be installed by a state qualified or licensed contractor. It is the responsibility of the person having the water heater installed to ensure the installing contractor has proper licenses and permits for installing water heaters in your location. Rinnai highly recommends that installers attend a product knowledge class to ensure customer satisfaction and warranty coverage. Failure to comply with state and local codes pertaining to water heater installations may void the warranty.

The V53i is not to be installed outdoors.

The V53e is not to be installed indoors.

A qualified installer or service technician should install the appliance, inspect it, and leak test it before use.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1. If installed in a manufactured home, the installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 and/or CAN/SCA Z240 MH Series, Mobile Homes.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa) (13.84 in W.C.).

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa) (13.84 in W.C.).

Follow the installation instructions and those in Care and Maintenance for adequate combustion and ventilation air.

The appliance should be located in an area where water leakage of the unit or connections will not result in damage to the area adjacent to the appliance or to lower floors of the structure. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the appliance. The pan must not restrict combustion air flow.

The flow of combustion and ventilation air shall not be obstructed. Combustion air shall not be supplied from occupied spaces.

This appliance is not suitable for use in an application such as a pool or spa heater that uses chemically treated water . (This appliance is suitable for filling large or whirlpool bath tubs with potable water.)

If a water heater is installed in a closed water supply system, such as one having a backflow preventer in the cold water supply line, means shall be provided to control thermal expansion. Contact the water supplier or local plumbing inspector on how to control thermal expansion.

Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.

Keep the air intake location free of chemicals such as chlorine or bleach that produce fumes. These fumes can damage components and reduce the life of your appliance.

For gas type conversion, contact Rinnai.

V53i & V53e Operation and Installation Manual

17

Image 17
Contents ANS Z21.10.3 CSA Result causing property damage, personal injury or deathTable of Contents V53i V53e SpecificationsSafety Definitions Consumer Safety InformationSafety Behaviors and Practices Safety Features Description of OperationFeatures Features Available on Temperature ControllersOperating Instructions MC-91 MCC-91 MC-100 BC-100 MC-502 DescriptionMC-91-1US & MCC-91-1US Temperature Controllers ModelsBC-100V-1US Setting the Sound Volume Voice Prompt How to Set the TemperatureTemperature Options Without a Temperature Controller Temperature Controller SettingsModel Temperature Settings Available ºF MCC-91 Temperature ControllerOverview Using the Water Smart / Bath Fill FunctionSetting the Water Volume Setting the Clock Setting Controller to MuteFilling the Tub Models MC-91 and MCC-91Maintenance Code Fault Remedy Error CodesCode Water Quality Trouble Shooting for Common IssuesAccessing Operating Information Circulating Pump Flushing the Heat Exchanger Error Code LC orGeneral Instructions Installation InstructionsV53iV53e Clearances from ApplianceAttachment of the Water Heater Gas Piping Electrical ConnectionV53i V53ePipe Sizing Procedure Example Freeze Protection Water PipingPressure Relief Valve Manual draining of the water heater When the water heater or external piping has frozenFreeze Protection Methods Rinnai Water Heater Freeze Protection PipingRinnai Water Heater Error Indication or Air Handler Control SwitchRecommended Piping for Basic Installation For this application Recommended Piping for Circulation SystemsFor this application Optional Piping for Circulation SystemsCondensate Venting InstructionsIntake / Exhaust Guidelines Manufacturer Product Parts Maximum Vent LengthVent Products Flue Installation Concentric Venting Flue Terminal Clearances ANS Z21.10.3, CSA Vent Terminal Area Where Terminal is not PermitttedInside Corner Additional ClearancesAdditional Clearances V53e High Altitude Installations Connecting Multiple Water HeatersNumber Connected Accessories Necessary Water Heaters GuidelinesCanada only Configurations Temperature Controller InstallationLocation Cable Lengths and SizeMounting the Controller Temperature ControllerTemperature Controller Installation V53e Operating Instructions For Your Safety Read Before OperatingOutlet Flow Data Technical DataPressure Drop Curve Replacement Temperature SettingSpace Heating PumpsV53i V53e DimensionsLadder Diagram for Ladder Diagram for V53e Consumer Support Warranty InformationLimited Warranty What will Rinnai do? Important In the State of Massachusetts 248 CMR 4.00 State RegulationsSupport à la clientele Instructions d’installationInstructions dutilisation Temp. d’eau Instructions dutilisationModel Arrangements de température disponibles ºF Plages de température avec un contrôleur de températureOptions de température sans contrôleur de température Nettoyage EntretienInstructions générales Instructions dinstallationFixation du chauffe-eau Écartements par rapport à lappareilInstructions générales Installation à altitude élevéeTuyauterie de gaz Soupape de sûreté Tuyauterie deauQualité de leau Légende Tuyauterie recommandée pour installation de baseCondensat Instructions de ventilationConsignes pour aspiration/évacuation Constructeur Produit Pièces Longueur maximum de ventilationProduits de ventilation Espacements pour terminaison de cheminée ANS Z21.10.3, CSA Installation de conduit de cheminée VanneMa ualmanuelleValve Instructions dutilisationFUS Ther Diagramme en escalierLinformation de garantie Support à la clientèleGarantie limitée Quest-ce qui est couvert ?Que fait Rinnai pour exercer la garantie ? VAM1620W, VB2020FFU

V53I, V53E specifications

When it comes to reliable and efficient tankless water heaters, Rinnai stands out with its exceptional models, the V53I and V53E. These units are designed to provide a continuous supply of hot water, making them ideal for a variety of applications, from residential homes to small commercial settings.

The Rinnai V53I is an indoor model that boasts advanced technology and a compact design. Its main feature is the ability to deliver up to 5.3 gallons of hot water per minute, depending on the inlet water temperature, which ensures that households can enjoy multiple hot water outlets simultaneously without the fear of running out. The unit employs advanced energy efficiency standards, which can lead to increased savings on energy bills. Additionally, it comes equipped with the Rinnai Circ-Logic technology, enabling users to set recirculation patterns that ensure hot water is readily available when needed.

On the other hand, the Rinnai V53E is engineered for outdoor installation, with weatherproof capabilities that make it resilient against the elements. Just like the V53I, it produces up to 5.3 gallons per minute, ensuring ample hot water supply. Both models are equipped with a patented heat exchanger system, designed for optimal performance and performance longevity. This means that users can rely on consistent hot water production over the lifetime of the unit.

One of the standout characteristics of these models is their compact design, making them easy to install even in tight spaces. Rinnai’s tankless technology eliminates the need for bulky storage tanks, allowing for more functional residential and commercial space. The durability and reliability of both models are further reinforced by a commercial-grade heat exchanger that can withstand high-demand situations.

From a safety perspective, both the V53I and V53E include multiple safety features, such as freeze protection and a range of venting options, providing peace of mind to users. Rinnai also emphasizes sustainability, with their units promoting reduced energy consumption and emissions compared to traditional water heating systems.

In summary, the Rinnai V53I and V53E models offer advanced technology, efficient performance, and user-friendly characteristics. Whether indoors or outdoors, these tankless water heaters are designed to meet the demands of modern living while contributing to energy savings and environmental sustainability. With Rinnai’s reputation for quality and reliability, homeowners and business owners alike can trust these models to deliver uninterrupted hot water, season after season.