Rinnai V53E, V53I State Regulations, Important In the State of Massachusetts 248 CMR 4.00

Page 46

State Regulations

NOTICE BEFORE INSTALLATION

Rinnai direct-vent appliance must be installed by a state qualified or licensed contractor and a properly trained Rinnai Installer. If you are not properly trained, you must not install this unit.

IMPORTANT: In the State of Massachusetts (248 CMR 4.00 & 5.00)

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL

OBSTRUCTIONS".

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

46

V53i & V53e Operation and Installation Manual

Image 46
Contents Result causing property damage, personal injury or death ANS Z21.10.3 CSATable of Contents Specifications V53i V53eSafety Behaviors and Practices Safety Features Consumer Safety InformationSafety Definitions Description of OperationOperating Instructions Features Available on Temperature ControllersFeatures MC-91 MCC-91 MC-100 BC-100 MC-502 DescriptionTemperature Controllers Models MC-91-1US & MCC-91-1USBC-100V-1US How to Set the Temperature Setting the Sound Volume Voice PromptModel Temperature Settings Available ºF Temperature Controller SettingsTemperature Options Without a Temperature Controller MCC-91 Temperature ControllerSetting the Water Volume Using the Water Smart / Bath Fill FunctionOverview Filling the Tub Setting Controller to MuteSetting the Clock Models MC-91 and MCC-91Maintenance Error Codes Code Fault RemedyCode Accessing Operating Information Trouble Shooting for Common IssuesWater Quality Flushing the Heat Exchanger Error Code LC or Circulating PumpInstallation Instructions General InstructionsAttachment of the Water Heater Clearances from ApplianceV53iV53e V53i Electrical ConnectionGas Piping V53ePipe Sizing Procedure Example Pressure Relief Valve Water PipingFreeze Protection Freeze Protection Methods When the water heater or external piping has frozenManual draining of the water heater Freeze Protection Piping Rinnai Water HeaterRecommended Piping for Basic Installation Error Indication or Air Handler Control SwitchRinnai Water Heater Recommended Piping for Circulation Systems For this applicationOptional Piping for Circulation Systems For this applicationIntake / Exhaust Guidelines Venting InstructionsCondensate Vent Products Maximum Vent LengthManufacturer Product Parts Flue Installation Concentric Venting Vent Terminal Area Where Terminal is not Permittted Flue Terminal Clearances ANS Z21.10.3, CSAAdditional Clearances Inside CornerAdditional Clearances V53e Number Connected Accessories Necessary Water Heaters Connecting Multiple Water HeatersHigh Altitude Installations GuidelinesCanada only Location Temperature Controller InstallationConfigurations Cable Lengths and SizeTemperature Controller Mounting the ControllerTemperature Controller Installation V53e For Your Safety Read Before Operating Operating InstructionsPressure Drop Curve Technical DataOutlet Flow Data Space Heating Temperature SettingReplacement PumpsDimensions V53i V53eLadder Diagram for Ladder Diagram for V53e Limited Warranty Warranty InformationConsumer Support What will Rinnai do? State Regulations Important In the State of Massachusetts 248 CMR 4.00Instructions dutilisation Instructions d’installationSupport à la clientele Instructions dutilisation Temp. d’eauOptions de température sans contrôleur de température Plages de température avec un contrôleur de températureModel Arrangements de température disponibles ºF Entretien NettoyageInstructions dinstallation Instructions généralesÉcartements par rapport à lappareil Fixation du chauffe-eauTuyauterie de gaz Installation à altitude élevéeInstructions générales Qualité de leau Tuyauterie deauSoupape de sûreté Tuyauterie recommandée pour installation de base LégendeConsignes pour aspiration/évacuation Instructions de ventilationCondensat Produits de ventilation Longueur maximum de ventilationConstructeur Produit Pièces Espacements pour terminaison de cheminée ANS Z21.10.3, CSA Installation de conduit de cheminée Instructions dutilisation VanneMa ualmanuelleValveDiagramme en escalier FUS TherGarantie limitée Support à la clientèleLinformation de garantie Quest-ce qui est couvert ?Que fait Rinnai pour exercer la garantie ? VAM1620W, VB2020FFU

V53I, V53E specifications

When it comes to reliable and efficient tankless water heaters, Rinnai stands out with its exceptional models, the V53I and V53E. These units are designed to provide a continuous supply of hot water, making them ideal for a variety of applications, from residential homes to small commercial settings.

The Rinnai V53I is an indoor model that boasts advanced technology and a compact design. Its main feature is the ability to deliver up to 5.3 gallons of hot water per minute, depending on the inlet water temperature, which ensures that households can enjoy multiple hot water outlets simultaneously without the fear of running out. The unit employs advanced energy efficiency standards, which can lead to increased savings on energy bills. Additionally, it comes equipped with the Rinnai Circ-Logic technology, enabling users to set recirculation patterns that ensure hot water is readily available when needed.

On the other hand, the Rinnai V53E is engineered for outdoor installation, with weatherproof capabilities that make it resilient against the elements. Just like the V53I, it produces up to 5.3 gallons per minute, ensuring ample hot water supply. Both models are equipped with a patented heat exchanger system, designed for optimal performance and performance longevity. This means that users can rely on consistent hot water production over the lifetime of the unit.

One of the standout characteristics of these models is their compact design, making them easy to install even in tight spaces. Rinnai’s tankless technology eliminates the need for bulky storage tanks, allowing for more functional residential and commercial space. The durability and reliability of both models are further reinforced by a commercial-grade heat exchanger that can withstand high-demand situations.

From a safety perspective, both the V53I and V53E include multiple safety features, such as freeze protection and a range of venting options, providing peace of mind to users. Rinnai also emphasizes sustainability, with their units promoting reduced energy consumption and emissions compared to traditional water heating systems.

In summary, the Rinnai V53I and V53E models offer advanced technology, efficient performance, and user-friendly characteristics. Whether indoors or outdoors, these tankless water heaters are designed to meet the demands of modern living while contributing to energy savings and environmental sustainability. With Rinnai’s reputation for quality and reliability, homeowners and business owners alike can trust these models to deliver uninterrupted hot water, season after season.