Rinnai V53I, V53E installation manual Freeze Protection Piping, Rinnai Water Heater

Page 23

Freeze Protection Piping

Vacuum

Breaker

Rinnai

Water Heater

3/4" Gas Connection

NOTE:

Heat trace ALL water pipe and fittings located outside home (attic, crawl space) or building structure. (ALL water pipe and fittings shown above the dashed line in the drawing.)

Gas Supply

NOTE:

ALL pipe and fittings shown below dashed line should be located inside home or building structure.

The vacuum breaker line should be located inside the building structure.

Minimum 3/4" Hot Water

Supply Line

1/2" Minimum

Normally Open

Solenoid Valve

S

3/4" Minimum

Normally Closed

Solenoid Valve

S

Route to Floor Drain

Minimum 3/4"

Cold Water

Supply Line

 

KEY

3/4" Ball Valve

Pressure Regulator

 

3/4" Union

Circulating Pump

Check Valve

Boiler Drain Valve

Pressure Relief Valve

S Solenoid Valve

This is not an engineered drawing. It is intended only as a guide and not as a replacement for professionally engineered project drawings. This drawing is not intended to describe a complete system. It is up to the contractor/engineer to determine the necessary components and configuration of the particular system being installed. This drawing does not imply compliance with local building code requirements. It is the responsibility of the contractor/engineer to ensure installation is in accordance with all local building codes. Confer with local building officials before installation.

V53i & V53e Operation and Installation Manual

23

Image 23
Contents ANS Z21.10.3 CSA Result causing property damage, personal injury or deathTable of Contents V53i V53e SpecificationsDescription of Operation Consumer Safety InformationSafety Definitions Safety Behaviors and Practices Safety FeaturesMC-91 MCC-91 MC-100 BC-100 MC-502 Description Features Available on Temperature ControllersFeatures Operating InstructionsMC-91-1US & MCC-91-1US Temperature Controllers ModelsBC-100V-1US Setting the Sound Volume Voice Prompt How to Set the TemperatureMCC-91 Temperature Controller Temperature Controller SettingsTemperature Options Without a Temperature Controller Model Temperature Settings Available ºFOverview Using the Water Smart / Bath Fill FunctionSetting the Water Volume Models MC-91 and MCC-91 Setting Controller to MuteSetting the Clock Filling the TubMaintenance Code Fault Remedy Error CodesCode Water Quality Trouble Shooting for Common IssuesAccessing Operating Information Circulating Pump Flushing the Heat Exchanger Error Code LC orGeneral Instructions Installation InstructionsV53iV53e Clearances from ApplianceAttachment of the Water Heater V53e Electrical ConnectionGas Piping V53iPipe Sizing Procedure Example Freeze Protection Water PipingPressure Relief Valve Manual draining of the water heater When the water heater or external piping has frozenFreeze Protection Methods Rinnai Water Heater Freeze Protection PipingRinnai Water Heater Error Indication or Air Handler Control SwitchRecommended Piping for Basic Installation For this application Recommended Piping for Circulation SystemsFor this application Optional Piping for Circulation SystemsCondensate Venting InstructionsIntake / Exhaust Guidelines Manufacturer Product Parts Maximum Vent LengthVent Products Flue Installation Concentric Venting Flue Terminal Clearances ANS Z21.10.3, CSA Vent Terminal Area Where Terminal is not PermitttedInside Corner Additional ClearancesAdditional Clearances V53e Guidelines Connecting Multiple Water HeatersHigh Altitude Installations Number Connected Accessories Necessary Water HeatersCanada only Cable Lengths and Size Temperature Controller InstallationConfigurations LocationMounting the Controller Temperature ControllerTemperature Controller Installation V53e Operating Instructions For Your Safety Read Before OperatingOutlet Flow Data Technical DataPressure Drop Curve Pumps Temperature SettingReplacement Space HeatingV53i V53e DimensionsLadder Diagram for Ladder Diagram for V53e Consumer Support Warranty InformationLimited Warranty What will Rinnai do? Important In the State of Massachusetts 248 CMR 4.00 State RegulationsSupport à la clientele Instructions d’installationInstructions dutilisation Temp. d’eau Instructions dutilisationModel Arrangements de température disponibles ºF Plages de température avec un contrôleur de températureOptions de température sans contrôleur de température Nettoyage EntretienInstructions générales Instructions dinstallationFixation du chauffe-eau Écartements par rapport à lappareilInstructions générales Installation à altitude élevéeTuyauterie de gaz Soupape de sûreté Tuyauterie deauQualité de leau Légende Tuyauterie recommandée pour installation de baseCondensat Instructions de ventilationConsignes pour aspiration/évacuation Constructeur Produit Pièces Longueur maximum de ventilationProduits de ventilation Espacements pour terminaison de cheminée ANS Z21.10.3, CSA Installation de conduit de cheminée VanneMa ualmanuelleValve Instructions dutilisationFUS Ther Diagramme en escalierQuest-ce qui est couvert ? Support à la clientèleLinformation de garantie Garantie limitéeQue fait Rinnai pour exercer la garantie ? VAM1620W, VB2020FFU

V53I, V53E specifications

When it comes to reliable and efficient tankless water heaters, Rinnai stands out with its exceptional models, the V53I and V53E. These units are designed to provide a continuous supply of hot water, making them ideal for a variety of applications, from residential homes to small commercial settings.

The Rinnai V53I is an indoor model that boasts advanced technology and a compact design. Its main feature is the ability to deliver up to 5.3 gallons of hot water per minute, depending on the inlet water temperature, which ensures that households can enjoy multiple hot water outlets simultaneously without the fear of running out. The unit employs advanced energy efficiency standards, which can lead to increased savings on energy bills. Additionally, it comes equipped with the Rinnai Circ-Logic technology, enabling users to set recirculation patterns that ensure hot water is readily available when needed.

On the other hand, the Rinnai V53E is engineered for outdoor installation, with weatherproof capabilities that make it resilient against the elements. Just like the V53I, it produces up to 5.3 gallons per minute, ensuring ample hot water supply. Both models are equipped with a patented heat exchanger system, designed for optimal performance and performance longevity. This means that users can rely on consistent hot water production over the lifetime of the unit.

One of the standout characteristics of these models is their compact design, making them easy to install even in tight spaces. Rinnai’s tankless technology eliminates the need for bulky storage tanks, allowing for more functional residential and commercial space. The durability and reliability of both models are further reinforced by a commercial-grade heat exchanger that can withstand high-demand situations.

From a safety perspective, both the V53I and V53E include multiple safety features, such as freeze protection and a range of venting options, providing peace of mind to users. Rinnai also emphasizes sustainability, with their units promoting reduced energy consumption and emissions compared to traditional water heating systems.

In summary, the Rinnai V53I and V53E models offer advanced technology, efficient performance, and user-friendly characteristics. Whether indoors or outdoors, these tankless water heaters are designed to meet the demands of modern living while contributing to energy savings and environmental sustainability. With Rinnai’s reputation for quality and reliability, homeowners and business owners alike can trust these models to deliver uninterrupted hot water, season after season.