Rinnai V53E, V53I installation manual Consumer Support, Warranty Information, Limited Warranty

Page 44

Consumer Support

Warranty Information

The installer is responsible for your water heater’s correct installation. Please complete the information below to keep for your records:

Model No.: ___________________________ Serial No.: __________________________________

Purchased from: ________________________________________________________________________

Address: __________________________________________________________________________

Phone: _______________________________

Date of Purchase: ___________________________

Installed by: ___________________________

Installer’s License No.: ________________________

Address: _____________________________

Phone: ____________________________________

Date of Installation: __________________________________

Limited Warranty

What is covered?

This Warranty covers any defects in materials or workmanship when the product is installed and operated according to Rinnai written installation instructions, subject to the terms within this Limited Warranty document. This Warranty applies only to products that are installed correctly. Improper installation may void this Warranty. Rinnai strongly suggests that you use a state qualified or licensed installer who has attended a Rinnai product knowledge class before installing this water heater. This Warranty extends to the original purchaser and subsequent owners, but only while the product remains at the site of the original installation. This Warranty only extends through the first installation of the product and terminates if the product is moved or reinstalled at a new location.

How long does coverage last?

 

 

V53i and V53e

 

 

Period of Coverage (from date of purchase)

Item

Residential Applications

Used for radiant heating with

 

 

or

Commercial Applications

 

Used with Rinnai Air Handler

other than Rinnai Air Handler

 

for domestic heating and water

 

 

Heat Exchanger

10 years *

3 years

No coverage

 

 

 

 

All Other Parts and Components

5 years *

3 years

No coverage

 

 

 

 

Reasonable Labor

1 year

1 year

No coverage

 

 

 

 

*Note: Period of coverage is reduced to 3 years from date of purchase when used as a circulating water heater within a hot water circulation loop, where the water heater is in series with a circulation system and all circulating water flows through the water heater, and where an on-demand recirculation system is not incorporated.

On-demand recirculation is defined as a hot water recirculating loop or system that utilizes existing hot and cold lines or a dedicated return line, and only activates when hot water is used. It can be activated by a push button, motion sensor, or voice activation but not by a temperature sensor. A timer added to a standard recirculating pump is not considered as on-demand.

There is no warranty coverage on product installed in a closed loop application, commonly associated with space heating only applications.

Use of an MCC-91 controller in a residential dwelling will reduce the warranty coverage to that of a commercial warranty application (except when an MCC-91 is used with a Rinnai Hydronic Air Handler).

44

V53i & V53e Operation and Installation Manual

Image 44
Contents Result causing property damage, personal injury or death ANS Z21.10.3 CSATable of Contents Specifications V53i V53eConsumer Safety Information Safety DefinitionsSafety Behaviors and Practices Safety Features Description of OperationFeatures Available on Temperature Controllers FeaturesOperating Instructions MC-91 MCC-91 MC-100 BC-100 MC-502 DescriptionTemperature Controllers Models MC-91-1US & MCC-91-1USBC-100V-1US How to Set the Temperature Setting the Sound Volume Voice PromptTemperature Controller Settings Temperature Options Without a Temperature ControllerModel Temperature Settings Available ºF MCC-91 Temperature ControllerOverview Using the Water Smart / Bath Fill FunctionSetting the Water Volume Setting Controller to Mute Setting the ClockFilling the Tub Models MC-91 and MCC-91Maintenance Error Codes Code Fault RemedyCode Water Quality Trouble Shooting for Common IssuesAccessing Operating Information Flushing the Heat Exchanger Error Code LC or Circulating PumpInstallation Instructions General InstructionsV53iV53e Clearances from ApplianceAttachment of the Water Heater Electrical Connection Gas PipingV53i V53ePipe Sizing Procedure Example Freeze Protection Water PipingPressure Relief Valve Manual draining of the water heater When the water heater or external piping has frozenFreeze Protection Methods Freeze Protection Piping Rinnai Water HeaterRinnai Water Heater Error Indication or Air Handler Control SwitchRecommended Piping for Basic Installation Recommended Piping for Circulation Systems For this applicationOptional Piping for Circulation Systems For this applicationCondensate Venting InstructionsIntake / Exhaust Guidelines Manufacturer Product Parts Maximum Vent LengthVent Products Flue Installation Concentric Venting Vent Terminal Area Where Terminal is not Permittted Flue Terminal Clearances ANS Z21.10.3, CSAAdditional Clearances Inside CornerAdditional Clearances V53e Connecting Multiple Water Heaters High Altitude InstallationsNumber Connected Accessories Necessary Water Heaters GuidelinesCanada only Temperature Controller Installation ConfigurationsLocation Cable Lengths and SizeTemperature Controller Mounting the ControllerTemperature Controller Installation V53e For Your Safety Read Before Operating Operating InstructionsOutlet Flow Data Technical DataPressure Drop Curve Temperature Setting ReplacementSpace Heating PumpsDimensions V53i V53eLadder Diagram for Ladder Diagram for V53e Consumer Support Warranty InformationLimited Warranty What will Rinnai do? State Regulations Important In the State of Massachusetts 248 CMR 4.00Support à la clientele Instructions d’installationInstructions dutilisation Instructions dutilisation Temp. d’eauModel Arrangements de température disponibles ºF Plages de température avec un contrôleur de températureOptions de température sans contrôleur de température Entretien NettoyageInstructions dinstallation Instructions généralesÉcartements par rapport à lappareil Fixation du chauffe-eauInstructions générales Installation à altitude élevéeTuyauterie de gaz Soupape de sûreté Tuyauterie deauQualité de leau Tuyauterie recommandée pour installation de base LégendeCondensat Instructions de ventilationConsignes pour aspiration/évacuation Constructeur Produit Pièces Longueur maximum de ventilationProduits de ventilation Espacements pour terminaison de cheminée ANS Z21.10.3, CSA Installation de conduit de cheminée Instructions dutilisation VanneMa ualmanuelleValveDiagramme en escalier FUS TherSupport à la clientèle Linformation de garantieGarantie limitée Quest-ce qui est couvert ?Que fait Rinnai pour exercer la garantie ? VAM1620W, VB2020FFU

V53I, V53E specifications

When it comes to reliable and efficient tankless water heaters, Rinnai stands out with its exceptional models, the V53I and V53E. These units are designed to provide a continuous supply of hot water, making them ideal for a variety of applications, from residential homes to small commercial settings.

The Rinnai V53I is an indoor model that boasts advanced technology and a compact design. Its main feature is the ability to deliver up to 5.3 gallons of hot water per minute, depending on the inlet water temperature, which ensures that households can enjoy multiple hot water outlets simultaneously without the fear of running out. The unit employs advanced energy efficiency standards, which can lead to increased savings on energy bills. Additionally, it comes equipped with the Rinnai Circ-Logic technology, enabling users to set recirculation patterns that ensure hot water is readily available when needed.

On the other hand, the Rinnai V53E is engineered for outdoor installation, with weatherproof capabilities that make it resilient against the elements. Just like the V53I, it produces up to 5.3 gallons per minute, ensuring ample hot water supply. Both models are equipped with a patented heat exchanger system, designed for optimal performance and performance longevity. This means that users can rely on consistent hot water production over the lifetime of the unit.

One of the standout characteristics of these models is their compact design, making them easy to install even in tight spaces. Rinnai’s tankless technology eliminates the need for bulky storage tanks, allowing for more functional residential and commercial space. The durability and reliability of both models are further reinforced by a commercial-grade heat exchanger that can withstand high-demand situations.

From a safety perspective, both the V53I and V53E include multiple safety features, such as freeze protection and a range of venting options, providing peace of mind to users. Rinnai also emphasizes sustainability, with their units promoting reduced energy consumption and emissions compared to traditional water heating systems.

In summary, the Rinnai V53I and V53E models offer advanced technology, efficient performance, and user-friendly characteristics. Whether indoors or outdoors, these tankless water heaters are designed to meet the demands of modern living while contributing to energy savings and environmental sustainability. With Rinnai’s reputation for quality and reliability, homeowners and business owners alike can trust these models to deliver uninterrupted hot water, season after season.