Rinnai Understanding Error Codes: Common Issues Including Code 12

Page 12

Error Codes

The Rinnai water heater has the ability to check its own operation continuously. If a fault occurs, an error code will flash on the Display of the temperature controller. This assists with diagnosing the fault and may enable you to overcome a problem without a service call. Please identify the code displayed when inquiring about service.

Code

Fault

 

Remedy

03

Power interruption during

 

Turn off all hot water taps. Press ON/OFF twice.

 

Bath Fill (Water will not flow

 

 

when power returns).

 

 

10

Air Supply or Exhaust

 

Ensure Rinnai approved venting materials are being used.

 

Blockage

 

Check that nothing is blocking the flue inlet or exhaust.

 

 

 

Check all vent components for proper connections.

 

 

 

Ensure vent length is within limits.

 

 

 

Verify dip switches are set properly.

 

 

 

Check fan for blockage.

 

 

 

Burner Sensor Error (see code 31)

 

 

 

Check the fins in the heat exchanger.

 

 

 

 

11

No Ignition

 

Check that the gas is turned on at the water heater, gas meter, or cylinder.

 

 

 

Ensure gas type and pressure is correct.

 

 

 

Ensure gas line, meter, and/or regulator is sized properly.

 

 

 

Bleed all air from gas lines.

 

 

 

Verify dip switches are set properly.

 

 

 

Ensure appliance is properly grounded.

 

 

 

Disconnect EZConnect™ or MSA controls to isolate the problem.

 

 

 

Ensure igniter is operational.

 

 

 

Check igniter wiring harness for damage.

 

 

 

Check gas solenoid valves for open or short circuits.

 

 

 

Remove burner cover and ensure all burners are properly seated.

 

 

 

Remove burner plate and inspect burner surface for condensation or debris.

 

 

 

 

12

Flame Failure

 

Check that the gas is turned on at the water heater and gas meter. Check for obstructions in

 

 

 

the flue outlet.

 

 

 

Ensure gas line, meter, and/or regulator is sized properly.

 

 

 

Ensure gas type and pressure is correct.

 

 

 

Bleed all air from gas lines.

 

 

 

Ensure proper Rinnai venting material was installed.

 

 

 

Ensure vent length is within limits.

 

 

 

Verify dip switches are set properly.

 

 

 

Ensure appliance is properly grounded.

 

 

 

Disconnect keypad.

 

 

 

Disconnect EZConnect™ or MSA controls to isolate the problem.

 

 

 

Check power supply for loose connections.

 

 

 

Check power supply for proper voltage and voltage drops.

 

 

 

Ensure flame rod wire is connected.

 

 

 

Check flame rod for carbon build-up.

 

 

 

Disconnect and reconnect all wiring harnesses on unit and PC board.

 

 

 

Check for DC shorts at components.

 

 

 

Check gas solenoid valves for open or short circuits.

 

 

 

Remove burner plate and inspect burner surface for condensation or debris.

 

 

 

Check the ground wire for the PC board.

14

Thermal Fuse

 

Check gas type of unit and ensure it matches gas type being used.

 

 

 

Check for restrictions in air flow around unit and vent terminal.

 

 

 

Check for low water flow in a circulating system causing short-cycling.

 

 

 

Ensure dip switches are set to the proper position.

 

 

 

Check for foreign materials in combustion chamber and/or exhaust piping.

 

 

 

Check heat exchanger for cracks and/or separations.

 

 

 

Check heat exchanger surface for hot spots which indicate blockage due to scale build-up.

 

 

 

Refer to instructions in manual for flushing heat exchanger.

 

 

 

Measure resistance of safety circuit.

 

 

 

Ensure high fire and low fire manifold pressure is correct.

 

 

 

Check for improper conversion of product.

 

 

 

 

12

 

Manual - Rinnai Condensing Water Heaters

Image 12
Contents Tankless Water Heater Operation and Installation Manual ANS Z21.10.3 CSATable of Contents Specifications RC80i RC80e RC98i RC98eConsumer Safety Information Safety DefinitionsSafety Behavior and Practices Safety Features Features Available on Temperature Controllers FeaturesDescription of Operation Operating InstructionsTemperature Controllers Models MC-91-1US & MCC-91-1USHow to Set the Temperature Temperature Controller SettingsModel Temperature Settings Available ºF Temperature Options Without a Temperature Controller Setting the Sound Volume Voice PromptRe-setting the Maximum Temperature MCC-91 Temperature ControllerUsing the Water Smart / Bath Fill Function Setting the Water VolumeBath Fill Temperature Settings Available OverviewSetting Controller to Mute Setting the ClockFilling the Tub Models MC-91 and MCC-91Maintenance Error Codes Code Fault RemedyOver Temperature CodeTrouble Shooting for Common Issues Accessing Operating InformationWater Quality Flushing the Heat Exchanger Error Code LC or Clean ThermistorsCirculating Pump Installation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterError Indication or Air Handler Control Switch Electrical ConnectionGas Piping General InstructionsPipe Sizing Procedure Example Isolation Valves Installation Instructions Pressure Relief Valve Installation InstructionsPressure Relief Valve Maintenance Water PipingPressure Relief Valve Freeze ProtectionWhen the water heater or external piping has frozen Freeze Protection PipingManual draining of the water heater Recommended Piping for Basic Installation Refer to the Condensate section in the venting instructionsRecommended Piping for Circulation Systems For this applicationAdditional installation requirements Venting InstructionsIntake / Exhaust Guidelines CondensateMaximum Vent Length Vent ProductsManufacturer Product Parts Description Canadian Installations US Installations Flue Terminal Clearances ANS Z21.10.3, CSAAdditional Clearances Vent Terminal RC80i, RC98i Inside CornerS ID E R N E R Flue Installation RC80i, RC98i Connecting Multiple Water Heaters High Altitude InstallationsNumber of Connected Water Heaters Accessories Necessary GuidelinesCanada only Temperature Controller Installation ConfigurationsLocation Cable Lengths and SizeMounting the Controller Outline of RemoteFor Your Safety Read Before Operating Operating InstructionsTechnical Data Pressure Drop CurveOutlet Flow Data Temperature Setting ReplacementSpace Heating PumpsDimensions RC80i, RC80eLadder Diagram State Regulations Important In the State of Massachusetts 248 CMR 4.00Warranty Information Limited WarrantyWhat is covered? Consumer SupportHow do I get service? What is not covered? What will Rinnai do?Limitation on warranties Instructions d’installation Instructions dutilisationInstructions dutilisation Chaud BrûlurePlages de température avec un contrôleur de température Options de température sans contrôleur à distanceModel Plages de température disponible ºF Les températures suggérées sont deEntretien Instructions d’installation Instructions généralesÉcartements par rapport à lappareil Fixation du chauffe-eauRC80i, RC98i Installations à haute altitude Tuyauterie de gaz Instructions généralesValve de dégagement de pression Instructions d’Installation Tuyauterie deauValve à Bille / Valve de dégagement de pression Qualité de leau Soupape de sûretéNiveau maximum Tuyauterie recommandée pour installation de base LégendeInstructions de ventilation Consignes pour aspiration/évacuationCondensat Longueur de ventilation maximum 12.5 m 10.7 mProduits de ventilation Manufacturer ProductEspacement pour terminaison de cheminée ANS Z21.10.3, CSA Nest PAS PermiseInstallation de conduit de cheminée RC80i, RC98i Instructions dutilisation VanneMa ualmanuelleValveDiagramme en escalier Phase NeutreSupport à la clientèle Informations sur la garantieQuest-ce qui est couvert ? Combien de temps dure la couverture ?Que fait Rinnai pour exercer la garantie ? Limitation sur les garantiesManual Rinnai Condensing Water Heaters U290-665X0300

RC80E, RC80I, RC98E, RC98I specifications

The Rinnai RC80E, RC98I, RC98E, and RC80I are high-efficiency tankless water heaters that exemplify leading-edge technology and engineering. Designed to meet the demands of modern households, these units provide continuous hot water while offering energy savings and compact sizes.

Starting with the RC80E, this model features a maximum flow rate of 8 gallons per minute, making it suitable for smaller homes or multi-family settings. It incorporates Rinnai's Circ-Logic technology, allowing homeowners to customize their hot water recirculation. This means users can schedule hot water availability, ensuring comfort while minimizing water waste.

The RC98I and RC98E models elevate performance, boasting a maximum flow rate of 9.8 gallons per minute. The "I" in RC98I stands for internal, indicating its built-in temperature control and Wi-Fi connectivity options. This allows for remote monitoring and control via a smartphone app, enhancing user convenience. In contrast, the "E" in RC98E indicates it has an external setting, providing flexibility for homeowners seeking installation options that cater to their specific needs.

All four models feature Rinnai’s condensing technology, which utilizes a dual heat exchanger design for superior efficiency. This not only lowers energy costs but also reduces CO2 emissions, aligning with eco-friendly standards. Additionally, they operate at an impressive Uniform Energy Factor (UEF), which is crucial for energy-conscious homeowners.

Safety is a significant consideration in Rinnai’s design philosophy. The RC80E, RC98I, RC98E, and RC80I come equipped with multiple safety features, including overheating protection and venting safeguards, ensuring peace of mind during operation. Their compact size allows for versatility in installation, fitting into tight spaces and freeing up valuable room in your home.

Moreover, these water heaters are designed for longevity, featuring a durable construction that resists corrosion. Rinnai's commitment to quality is evident in their extensive warranty, proving their confidence in the product’s reliability.

In summary, the Rinnai RC80E, RC98I, RC98E, and RC80I units represent a blend of advanced technology, efficiency, and convenience. With significant flow rates, innovative features like Circ-Logic and Wi-Fi compatibility, as well as robust safety measures, they are an excellent choice for any homeowner looking to enhance their hot water experience while promoting energy efficiency.