Rinnai RC98E, RC98I, RC80I, RC80E installation manual Pressure Relief Valve, Freeze Protection

Page 21

General Instructions

A manual water control valve must be placed in the water inlet connection to the Rinnai water heater before it is connected to the water line. Unions may be used on both the hot and cold water lines for future servicing and disconnection of the unit.

The piping (including soldering materials) and components connected to this appliance must be approved for use in potable water systems.

Purge the water line to remove all debris and air. Debris will damage the Rinnai water heater.

Toxic chemicals such as those used for boiler water treatment are not to be introduced to the potable water used for space heating.

If the appliance will be used as a potable water source, it must not be connected to a system that was previously used with a nonpotable water heating appliance.

Ensure that the water filter on the Rinnai water heater is clean and installed.

Pressure Relief Valve

An approved pressure relief valve is required by the American National Standard (ANSI Z21.10.3) / Canadian Standard (CSA 4.3) for all water heating systems.

The relief valve must comply with the standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems ANSI Z21.22 and /or the standard Temperature, Pressure, Temperature and Pressure Relief Valves and Vacuum Relief Valves, CAN1-4.4.

The relief valve must be rated up to 150 psi and to at least the maximum BTU/hr of the appliance.

The discharge from the pressure relief valve should be piped to the ground or into a drain system to prevent exposure or possible burn hazards to humans or other plant or animal life. Follow local codes. Water discharged from the relief valve could cause severe burns instantly, scalds, or death.

The pressure relief valve must be manually operated once a year to check for correct operation.

The relief valve should be added to the hot water outlet line according to the manufacturer’s instructions. DO NOT place any other type valve or shut off device between the relief valve and the water heater.

Do not plug the relief valve and do not install any reducing fittings or other restrictions in the relief line. The relief line should allow for complete drainage of the valve and the line.

If a relief valve discharges periodically, this may be due to thermal expansion in a closed water supply system. Contact the water supplier or local plumbing inspector on how to correct this situation. Do not plug the relief valve.

Neither Rinnai nor the American National Standard (ANSI Z21.10.3) / Canadian Standard (CSA 4.3) requires a combination temperature and pressure relief valve for this appliance. However, local codes may require a combination temperature and pressure relief valve.

Freeze Protection

The freeze protection features include electrical heating elements. Freeze protection may be disabled if electricity is not supplied, or if there is an error preventing the water heater from functioning. Loss of freeze protection may result in water damage from a burst heat exchanger or water lines.

The installation of auto drain down solenoid valves is optional. However, Rinnai strongly recommends that these valves be installed to prevent damage from freezing in case the normal freeze protection should become disabled. Any product damage due to freezing will not be covered by the warranty.

In addition, the solenoid valves should be connected electrically to a surge protector with terminals. This allows the solenoid valves to operate if the water heater is disabled due to an error code.

The condensate trap drain plug and water drain plug are not affected by the auto drain down solenoid valves and will have to be manually opened.

The freeze protection features will not prevent the external piping from freezing. Rinnai recommends heat tracing and insulating hot and cold water pipes connecting units. Pipe cover enclosures may be packed with insulation for added freeze protection.

With electrical power supplied, Rinnai condensing water heaters will not freeze when the outside air temperature is as cold as –22ºF (-30ºC) for indoor models or is as cold as –4ºF (-20ºC) for outdoor models, when protected from direct wind exposure. Because of the “wind-chill” effect, any wind or circulation of the air on the unit will reduce its ability to freeze protect.

The solenoid valves and surge protector with terminals are available for purchase at Rinnai.

Manual - Rinnai Condensing Water Heaters

21

Image 21
Contents ANS Z21.10.3 CSA Tankless Water Heater Operation and Installation ManualTable of Contents RC80i RC80e RC98i RC98e SpecificationsConsumer Safety Information Safety DefinitionsSafety Behavior and Practices Safety Features Features Features Available on Temperature ControllersDescription of Operation Operating InstructionsMC-91-1US & MCC-91-1US Temperature Controllers ModelsHow to Set the Temperature Temperature Controller SettingsModel Temperature Settings Available ºF Setting the Sound Volume Voice Prompt Temperature Options Without a Temperature ControllerRe-setting the Maximum Temperature MCC-91 Temperature ControllerSetting the Water Volume Using the Water Smart / Bath Fill FunctionBath Fill Temperature Settings Available OverviewSetting the Clock Setting Controller to MuteFilling the Tub Models MC-91 and MCC-91Maintenance Code Fault Remedy Error CodesCode Over TemperatureTrouble Shooting for Common Issues Accessing Operating InformationWater Quality Flushing the Heat Exchanger Error Code LC or Clean ThermistorsCirculating Pump General Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceElectrical Connection Error Indication or Air Handler Control SwitchGas Piping General InstructionsPipe Sizing Procedure Example Pressure Relief Valve Installation Instructions Isolation Valves Installation InstructionsPressure Relief Valve Maintenance Water PipingFreeze Protection Pressure Relief ValveWhen the water heater or external piping has frozen Freeze Protection PipingManual draining of the water heater Refer to the Condensate section in the venting instructions Recommended Piping for Basic InstallationFor this application Recommended Piping for Circulation SystemsVenting Instructions Additional installation requirementsIntake / Exhaust Guidelines CondensateMaximum Vent Length Vent ProductsManufacturer Product Parts Flue Terminal Clearances ANS Z21.10.3, CSA Description Canadian Installations US InstallationsInside Corner Additional Clearances Vent Terminal RC80i, RC98iS ID E R N E R Flue Installation RC80i, RC98i High Altitude Installations Connecting Multiple Water HeatersNumber of Connected Water Heaters Accessories Necessary GuidelinesCanada only Configurations Temperature Controller InstallationLocation Cable Lengths and SizeOutline of Remote Mounting the ControllerOperating Instructions For Your Safety Read Before OperatingTechnical Data Pressure Drop CurveOutlet Flow Data Replacement Temperature SettingSpace Heating PumpsRC80i, RC80e DimensionsLadder Diagram Important In the State of Massachusetts 248 CMR 4.00 State RegulationsLimited Warranty Warranty InformationWhat is covered? Consumer SupportHow do I get service? What is not covered? What will Rinnai do?Limitation on warranties Instructions dutilisation Instructions d’installationChaud Brûlure Instructions dutilisationOptions de température sans contrôleur à distance Plages de température avec un contrôleur de températureModel Plages de température disponible ºF Les températures suggérées sont deEntretien Instructions générales Instructions d’installationÉcartements par rapport à lappareil Fixation du chauffe-eauRC80i, RC98i Installations à haute altitude Instructions générales Tuyauterie de gazValve de dégagement de pression Instructions d’Installation Tuyauterie deauValve à Bille / Valve de dégagement de pression Qualité de leau Soupape de sûretéNiveau maximum Légende Tuyauterie recommandée pour installation de baseInstructions de ventilation Consignes pour aspiration/évacuationCondensat 12.5 m 10.7 m Longueur de ventilation maximumManufacturer Product Produits de ventilationNest PAS Permise Espacement pour terminaison de cheminée ANS Z21.10.3, CSAInstallation de conduit de cheminée RC80i, RC98i VanneMa ualmanuelleValve Instructions dutilisationPhase Neutre Diagramme en escalierInformations sur la garantie Support à la clientèleQuest-ce qui est couvert ? Combien de temps dure la couverture ?Limitation sur les garanties Que fait Rinnai pour exercer la garantie ?Manual Rinnai Condensing Water Heaters U290-665X0300

RC80E, RC80I, RC98E, RC98I specifications

The Rinnai RC80E, RC98I, RC98E, and RC80I are high-efficiency tankless water heaters that exemplify leading-edge technology and engineering. Designed to meet the demands of modern households, these units provide continuous hot water while offering energy savings and compact sizes.

Starting with the RC80E, this model features a maximum flow rate of 8 gallons per minute, making it suitable for smaller homes or multi-family settings. It incorporates Rinnai's Circ-Logic technology, allowing homeowners to customize their hot water recirculation. This means users can schedule hot water availability, ensuring comfort while minimizing water waste.

The RC98I and RC98E models elevate performance, boasting a maximum flow rate of 9.8 gallons per minute. The "I" in RC98I stands for internal, indicating its built-in temperature control and Wi-Fi connectivity options. This allows for remote monitoring and control via a smartphone app, enhancing user convenience. In contrast, the "E" in RC98E indicates it has an external setting, providing flexibility for homeowners seeking installation options that cater to their specific needs.

All four models feature Rinnai’s condensing technology, which utilizes a dual heat exchanger design for superior efficiency. This not only lowers energy costs but also reduces CO2 emissions, aligning with eco-friendly standards. Additionally, they operate at an impressive Uniform Energy Factor (UEF), which is crucial for energy-conscious homeowners.

Safety is a significant consideration in Rinnai’s design philosophy. The RC80E, RC98I, RC98E, and RC80I come equipped with multiple safety features, including overheating protection and venting safeguards, ensuring peace of mind during operation. Their compact size allows for versatility in installation, fitting into tight spaces and freeing up valuable room in your home.

Moreover, these water heaters are designed for longevity, featuring a durable construction that resists corrosion. Rinnai's commitment to quality is evident in their extensive warranty, proving their confidence in the product’s reliability.

In summary, the Rinnai RC80E, RC98I, RC98E, and RC80I units represent a blend of advanced technology, efficiency, and convenience. With significant flow rates, innovative features like Circ-Logic and Wi-Fi compatibility, as well as robust safety measures, they are an excellent choice for any homeowner looking to enhance their hot water experience while promoting energy efficiency.