Stovax P8701CFCHEC, P8700CFCHEC manual Safety Precautions, Installation of the appliance

Page 13

INSTALLATION INSTRUCTIONS

INSTALLATION

IMPORTANT: REFER TO DATA BADGE AND TECHNICAL SPECIFICATION AT THE FRONT OF THE MANUAL TO ENSURE THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLIED IN THE COUNTRY OF USE.

FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SECTION 10, SERVICING, ‘REPLACING PARTS’.

1.SAFETY PRECAUTIONS

1.1For your own and other’s safety, you must install this appliance according to local and national codes of practice. Failure to install the stove correctly could lead to prosecution:

Read these instructions before installing and using this stove.

1.2These instructions must be left intact with the user.

1.3Do not attempt to burn rubbish on this appliance.

1.4Keep all plastic bags away from young children.

1.5Do not place any object on or near to the appliance and allow adequate clearance above the appliance.

IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT THE APPLIANCE.

2.installation of the appliance

1.1This appliance can be installed in four different ways:

1)Builder’s opening with a frame

2)Builder’s opening without a frame

3)Stud work with a frame

4)Stud work without a frame

Where no frame is used an edge kit is available to enable the installer to plaster to a finished edge: Kit No. 8727 CFFK01 for Studio 1 and 8727 CFFK02 for Studio 2

Options 1) and 2) above can be:

top exit with a liner

rear exit without a liner

1.2The Studio is supplied with a flue fixing plate to attach the flue to the appliance within the aperture, Diagram 1.

1

AR1010

When installing the appliance into a masonry chimney without a liner, it must be converted to a rear exit:

Remove the two fixing screws securing the spigot assembly

Slide the blanking plate into the guides

Replace the two fixing screws, Diagram 2

2

AR2007

The flue must be in good condition and clear products of combustion, see Commissioning)

Option 3) and 4) must be fitted using the top exit only with rigid twin wall flue pipe.

THE APPLIANCE IS SUPPLIED WITH A WALL BOX CONTAINING THE BATTERIES AND TOUCH PAD. THIS MUST BE RECESSED INTO THE WALL WITH ACCESS FOR THE CABLES PRIOR TO FITTING THE APPLIANCE.

2.1Remove the appliance from the carton and discard all unnecessary packaging. Ensure no components are thrown away when unpacking.

2.2To access the controls and gas inlet:

Remove the glass door, enamelled liners, burner and splitter plate. See Section 4

2.3The gas supply enters the fire through a silicon panel on the floor under the access panel, Diagram 3:

Slit with a sharp knife before bringing through the supply pipe, Diagram 1

13

Image 13
Contents Studio PR0957 Studio Issue 3 JanuaryCovering the Following Model Studio 1 conventional flue FLUE CHECK APPLIANCE COMMISSIONING CHECKLISTFail GAS CHECKUser Instructions MAN ModeGeneral Lighting the Studio2B Touch PAD Control Using the allen key provided Cleaning the StudioChanging the Studio Batteries Emergency Shut OFFHOT SURFACES Arrangement of Fuel BEDFire will not Light Technical Specification Installation InstructionsCovering the Following Models Qty Description Fixing Kit containing Packing ChecklistDimension Studio Steel Frame DimensionsBauhaus Frame Dimensions Studio 846 1046 520 750 950 424 12.5Flue Options SITE REQUIREMENTSGAS Supply Ventilation440 1160 Safety Precautions InstallationInstallation of the appliance Stud Work Installation Method 1 Frame Stud Work InstallationThere is AN Optional Duct KIT, Code No AR1903 Stud Work Installation Method 2 Edge Door is now free to remove, Diagram Masonry chimney InstallationRemove the remaining rear and lower panel, Diagram Method 1 Frame Method 2 no Frame To replace the doors and panels, refer to Replacing Parts,Assembling the Appliance Both Method 1 or 2 Masonry InstallationBy thermostatic remote control Using the fire’s touch pad Thermostatic Remote ControlLighting the Studio Touch PAD ControlCommissioning For future reference, record the installation details onCommissioning Servicing Instructions Servicing / Fault Finding ChartsServicing Requirements Flame Failure Functional Check Ignition Functional CheckWindow Frame Assembly Replacing PartsGeneral Decorative FrameBlack Enamelled Panels Glass WindowMaIN Burner Ensure no stone pebbles fall into the pilot areaPilot Unit Assembly MaIN Control AssemblyRemove the screw retaining the pilot cover, Diagram Ignition LeadRemove the cover fixing screw, Diagram Magnetic safety valveGAS Valve Control BOXMain injector Debris Area AccessPrimary Aeration Plate Changing between Gas TypesAccess to the pressure test point can now be reached Diagram Pressure and Leak Testing the ApplianceG30 N/A ShoRt Spares ListG31 N/A Service Records Member of the Stovax Group

8701CFCHEC, P8700CFCHEC, P8701CFCHEC, 8700CFCHEC specifications

Stovax, a renowned name in the world of wood-burning stoves and fireplaces, offers a range of high-performance heating solutions designed for both efficiency and aesthetics. Among their standout models are the P8701CFCHEC and P8700CFCHEC, as well as their closely related variants, 8701CFCHEC and 8700CFCHEC. These models showcase the commitment of Stovax to blend modern technology with traditional heating methods.

One of the most notable features of the P8701CFCHEC and P8700CFCHEC models is their advanced combustion technology. Designed to maximize efficiency, these stoves provide a clean and efficient burn, minimizing emissions and maximizing heat output. This ensures not only a warm environment but also compliance with contemporary environmental standards. The combustion system is engineered to enhance air circulation within the firebox, which promotes a more complete burn of the fuel, resulting in reduced fuel consumption.

Both models come with a contemporary yet adaptable aesthetic, allowing them to seamlessly fit into a variety of interior design styles. Their sleek faces and clean lines add a touch of modern sophistication, making them suitable for both traditional and contemporary homes. The large glass windows patented by Stovax provide an expansive view of the flickering flames, creating a cozy atmosphere while also serving as a focal point in any room.

In terms of versatility, the P8701CFCHEC and P8700CFCHEC models allow for multiple installation options. They can be fitted into existing fireplaces or used as stand-alone units, catering to different homeowner preferences. Additionally, they can be used with various flue systems, enhancing their adaptability to different living spaces.

Further elevating the user experience, these stoves are designed with easy-to-use controls that allow for precise adjustment of the heat output, making it easy to maintain a comfortable living environment. The built-in air wash system helps keep the glass clean, ensuring that users can enjoy uninterrupted views of the fire without the hassle of frequent maintenance.

In conclusion, the Stovax P8701CFCHEC and P8700CFCHEC models, along with their variants, represent a fusion of classic wood-burning technology with contemporary design and unparalleled efficiency. They are perfect choices for anyone looking to enhance their home heating solution while also adding a touch of style and comfort.