Desa CGDV32pR, T32N-a SERIES, T32p-a SERIES Plug in blower power cord, Model BKT Installation

Models: T32N-a SERIES T32p-a SERIES CGDV32pR

1 44
Download 44 pages 4.36 Kb
Page 18
Image 18

Fireplace

Installation

Continued

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 26, page 17).

4.Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retaining the green ground wire is tight.

5.Mount speed control box to switch bracket by placing the plastic control shaft forward through the opening in the switch bracket (see Figure 27).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob pro- vided on shaft.

7.Turn on power to duplex outlet if previously turned off per the warning in column 2, page 17.

8.Plug in blower power cord.

a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox.

b.If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox owner’s manual for instructions on wiring the duplex outlet.

CAUTION: Never touch the blower wheel while in operation.

9.Check to make sure that the power cord is com- pletely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by turning knob fully counterclock- wise before continuing.

10.Peel off the backing paper and stick the sup- plied wiring diagram decal on the firebox bot- tom approximately 12" in front of the blower (see Figure 28).

Speed

Switch Control

BracketBlower

Plug-In

 

Control

Duplex Outlet

Locknut

(Located

Control

Shaft

underneath

Knob

 

firebox floor

 

 

against lower

 

 

right outside

 

 

wall)

Figure 27 - Attaching Speed Control to

Firebox

Wiring Diagram

Decal 12" in Front

of Blower

Figure 28 - Location of Wiring Diagram Decal (Model May Vary From Illustration)

Model BKT Installation

Note: When installing the BKT thermostati- cally-controlled blower, you must first secure the thermal switch bracket to the blower if it has not already been factory installed.

1.Place the green ground wire with ring termi- nal between the bottom hole on the thermal switch bracket and the top ear hole on the blower assembly. Insert the phillips screw into all three pieces and tighten securely (see Figure 29, page 19).

2.Connect wire harness and power cord ter- minals. Connect the blue jumper wire to the blower motor terminal and the right side ter- minal of the thermal switch. Connect the black wire to the left side of the thermal switch and the white wire to the other remaining blower motor terminal.

Note: The power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connections. DO NOT trim excessive length away. Just enable enough to make all connections securely.

18

www.desatech.com

116646-01D

Page 18
Image 18
Desa CGDV32pR, T32N-a SERIES, T32p-a SERIES installation manual Plug in blower power cord, Model BKT Installation