HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS

The following configurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows.

Venting with Two 90° Elbows

 

 

Horizontal (H1) +

Vertical (V)

Horizontal (H1)

Horizontal (H2)

5' min.

2' max.

6' max.

6' min.

4' max.

12' max.

7' min.

6' max.

18' max.

8' min.

8' max.

20' max.

20' max.

8' max.

20' max.

45° Elbow

Figure 17 - Horizontal Termination Configuration for Venting Using Two 90° Elbows

Venting with Two 90° Elbows

 

 

Horizontal (H1) +

 

Vertical (V) Horizontal (H2)

 

5' min.

6' max.

 

6' min.

12' max.

 

7' min.

18' max.

45° Elbow

8' min.

20' max.

 

20' max.

20' max.

 

Figure 18 - Horizontal Termination Configuration for Venting Using Two 90° Elbows