TROUBLESHOOTING Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces unwanted

1.

Gas leak. See Warning

1.

Locate and correct all leaks

 

odors

 

statement above

 

(see Checking Gas Connec-

 

 

 

 

tions, page 21)

 

 

 

 

 

Gas odor even when control

1.

Gas leak. See Warning

1.

Locate and correct all leaks

knob is in OFF position

 

statement above

 

(see Checking Gas Connec-

 

2.

Control valve defective

2.

tions, page 21)

 

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Gas leak. See Warning

1.

Locate and correct all leaks

 

 

statement above

 

(see Checking Gas Connec-

 

 

 

 

tions, page 21)

Dark residue on logs or inside

1.

Improper log placement

1.

Properly locate logs (see In-

of fireplace

 

 

 

stalling Logs, Lava Rock and

 

2.

Air holes at burner inlet

2.

Glowing Embers, page 25)

 

Clean out air holes at burner

 

 

blocked

 

inlets. Periodically repeat as

 

3.

Burner flame holes blocked

3.

needed

 

Remove blockage or replace

 

4.

Improper venting or excessive

4.

burner

 

Have the vent system inspect-

 

 

blockage

 

ed, including the termination

 

 

 

 

cap. Remove any restrictions

 

5.

Excessive amounts of embers

5.

or obstruction

 

Clear excess embers until a

 

 

and pan material

 

minimum gap of 1/2" remains

 

 

 

 

under the grate

116646-01D