SAFETY INFORMATION

Continued

9.Do not use this fireplace to cook food or burn paper or other objects.

10.This appliance, when installed, must be electri- cally grounded in accordance with local codes or, in the absence of local codes, with the

National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1.

11.Do not use fireplace if any part has been under water. Immediately call a qualified service per- son to arrange for replacement of the unit.

12.Do not operate fireplace if log is broken.

13.Provide adequate clearances around air openings.

Product

Identification

Upper Louver Panel Glass Door Assembly

Nailing

Flue

Collar

Flange

Log

 

Piezo

Set

 

Ignitor

 

Control

 

Valve

 

Lower

Glowing

 

 

Louver

 

 

Embers

 

 

Panel

 

 

 

 

 

ON/OFF/REMOTE Switch

Grate

 

(Optional Installation)

 

Assembly

 

Blower Switch

Lava

 

Rock

 

(Optional Installation)

Figure 1 - Direct-Vent Fireplace with

Millivolt Ignition

Local Codes

Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the cur- rent National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Installation Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Product Features

These are a few facts that can help you understand and enjoy your direct-vent fireplace:

The venting system may be routed to the out- side of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exterior wall (horizontal). The vent pipe installation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications.

This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed.

This fireplace does not require electricity to operate.

Only the blower requires electricity if installed. If you plan to install the blower at a later date, outlet must be wired at the bottom of the fire- place when framing.

A piezo ignitor and ceramic electrode create sparks to ignite the pilot light. It does not require any matches, batteries or any other sources of ignition to light the pilot.

Each time you turn on your fireplace, you may notice some amount of condensation on the in- side of the fireplace glass. This is normal and will disappear after 10-20 minutes of operation.

Your direct-vent gas fireplace system (fireplace and venting) is a balanced and sealed gas op- erating unit. It requires approximately 10-20 minutes of operating time before the flame pattern stabilizes.

Fireplaces with the suffix of -HA have been designed to operate at altitudes of 4000 feet and above.

www.desatech.com116646-01D