Stovax (P)8135, (P)8143, (P)8119, (P)8127, (P)8136, (P)8144, (P)8120, (P)8128 manual Installation

Page 15

INSTALLATION INSTRUCTIONS

INSTALLATION

IMPORTANT:ENSURE THAT THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE. REFER TO DATABADGE AND TECHNICAL SPECIFICATIONS AT THE FRONT OF THE BOOKLET.

FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SERVICING SECTION 9.

1.SAFETY PRECAUTIONS

1.1This appliance must be installed in accordance with the rules in force, and used only in a sufficiently ventilated space. Please read these instructions before installation and use of this appliance.

1.2These instructions must be left intact with the user.

1.3Do not attempt to burn rubbish on this appliance.

1.4In your own interest, and those of safety, this appliance must be installed by competent persons in accordance with local and national codes of practice. Failure to install the appliance correctly could lead to prosecution.

1.5Keep all plastic bags away from young children.

2.UNPACKING

2.1Remove the appliance from its packaging, and check that it is complete and undamaged.

2.2Put the loose ceramic parts to one side so that they are not damaged during installation.

3.INSTALLATION

These fires have preset High and Low settings with a Gas working pressure as listed below.

20mb on Natural Gas, 29mb on Butane and 37mb on Propane with the fire on full.

3.1Ensure the minimum opening dimensions are correct, place the decorative basket in the opening ensuring that is sits centrally.

3.2Place the gas fire unit centrally into the decorative basket and mark the fixing positions through the holes in the tray feet.

3.3Remove both the decorative basket and fire, drill the marked holes and insert the rawplugs provided. Place the gas fire in position and secure to the hearth using the screws provided. See diagram 1.

1

3.4Connect the gas supply to the 8mm compression elbow situated to the right of the valve ensuring the supply pipe will not interfere with the fit of the decorative components. See diagram 2.

2

If the isolation tap is to be fitted under the fire, the GAZCO GC00060 provides a neat and easy solution.

3.5Place the decorative components in place ensuring they sit centrally around the fire.

15

Image 15
Contents Aspen, Chamonix & Tahoe Decorative Gas Basket Fires Contents Appliance Commissioning Checklist Flue Check Pass FailGAS Check Turning the Appliance OFF User InstructionsGeneral Lighting the ApplianceCleaning the Fire Upgrading Your FireArrangement of Fuel BED Components Coal & Pebble Layout Small Aspen & Chamonix Coal & Pebble Layout Tahoe Coal & Pebble Layout Medium Chamonix, Large Aspen & ChamonixLog & Driftwood Layout Small Aspen & Chamonix AR1276 Log & Driftwood Layout Tahoe Servicing Oxygen Depletion SensorFlame Failure Device RunningHigh Flue and Chimney Requirements Installation InstructionsInstallation of the GAS Supply Site RequirementsAppliance Location Control UpgradeUnpacking InstallationSafety Precautions InstallationArrangement of Fuel BED Components AR1265 AR1268 AR1277 AR1274 AR1278 AR1285 Commissioning CommissioningServicing / Fault Finding Charts Servicing InstructionsServicing Requirements Ignition Functional Check Ignition Functional CheckFlame Failure Functional Check Fault Finding ChartsReplacing Parts Fire RemovalIgnition Lead ODS Pilot Unit PiezoMagnetic Unit Main InjectorPrimary Aeration Plate Engine Assembly Air Box Gasket Pilot Assembly Databadge GAS ValveChanging Between GAS Types LPG Gas Components Natural Gas ComponentsService Records Member of the Stovax Group