Stovax (P)8135, (P)8143, (P)8119, (P)8127, (P)8136, (P)8144, (P)8120, (P)8128 manual

Page 8

USER INSTRUCTIONS

7.6.3Place one large coal or pebble on top of the pilot shield, then place 10 alternating large and small coals or pebbles around the perimeter of the fire. They should sit on the bottom row of small coals or pebbles and rest against the inner mass of square blocks. Place one small coal or pebble on top of the centre of the square blocks. See diagram 15.

15

AR1272

7.6.4Place the remaining 4 large coals or pebbles on top of the square blocks, ensure that they lean against the central small coal or pebble and that there are gaps between each coal or pebble. See diagram 16.

16

AR1273

7.7 Log & Driftwood Layout – Small Aspen & Chamonix

It may be necessary to make small changes to the log positioning in order to achieve the most pleasing flame effect but the following guidelines should be followed.

7.7.1Refer to the log identification chart and identify the numbers corresponding to the logs that have been supplied. See diagram 17

17

8

7.7.2Place the two logs (No.13) on top of the beads as shown. See diagram 18.

18

AR1274

7.7.3Place the large log (No. 1) so that it sits on top of the previous two logs. Place the burnt effect log (No. B1) in the centre of the tray as shown. See diagram 19.

19

AR1275

8

Image 8
Contents Aspen, Chamonix & Tahoe Decorative Gas Basket Fires Contents GAS Check Appliance Commissioning ChecklistFlue Check Pass Fail User Instructions GeneralLighting the Appliance Turning the Appliance OFFArrangement of Fuel BED Components Cleaning the FireUpgrading Your Fire Coal & Pebble Layout Small Aspen & Chamonix Coal & Pebble Layout Medium Chamonix, Large Aspen & Chamonix Coal & Pebble Layout TahoeLog & Driftwood Layout Small Aspen & Chamonix AR1276 Log & Driftwood Layout Tahoe Oxygen Depletion Sensor Flame Failure DeviceRunning ServicingHigh Installation Instructions Installation of the GAS SupplySite Requirements Flue and Chimney RequirementsControl Upgrade Appliance LocationInstallation Safety PrecautionsInstallation UnpackingArrangement of Fuel BED Components AR1265 AR1268 AR1277 AR1274 AR1278 AR1285 Commissioning CommissioningServicing Requirements Servicing / Fault Finding ChartsServicing Instructions Ignition Functional Check Ignition Functional CheckFault Finding Charts Flame Failure Functional CheckIgnition Lead Replacing PartsFire Removal Piezo ODS Pilot UnitPrimary Aeration Plate Magnetic UnitMain Injector Changing Between GAS Types Engine Assembly Air Box Gasket Pilot Assembly DatabadgeGAS Valve Natural Gas Components LPG Gas ComponentsService Records Member of the Stovax Group