INSTALLATION INSTRUCTIONS
COMMISSIONING
6.COMMISSIONING
6.1Close all windows and doors to the room, check all controls, and allow fire to burn on maximum for 5 minutes. Test for spillage of flue products using a smoke match. Pass the lighted smoke match along the top front edge just inside the opening or canopy. See diagram 34.
34
6.2If the fire spills, run for a further 10 minutes and
6.3If there are extractor fans in the room or adjacent rooms, the spillage test must be repeated with the extractors running on maximum.
6.4The burner pressure on this appliance is
( The test points on the gas valve are not used on this appliance.)
22