Stovax (P)8135, (P)8143, (P)8119, (P)8127, (P)8136, (P)8144, (P)8120, (P)8128 manual AR1277 AR1274

Page 19

INSTALLATION INSTRUCTIONS

INSTALLATION

5.6.4Place the remaining 4 large coals or pebbles on top of the square blocks, ensure that they lean against the central small coal or pebble and that there are gaps between each coal or pebble. See diagram 17.

17

AR1273

5.7 Log & Driftwood Layout – Small Aspen & Chamonix

It may be necessary to make small changes to the log positioning in order to achieve the most pleasing flame effect but the following guidelines should be followed.

5.7.1Refer to the log identification chart and identify the numbers corresponding to the logs that have been supplied. See diagram 18

18

8

5.7.3Place the large log (No. 1) so that it sits on top of the previous two logs. Place the burnt effect log (No. B1) in the centre of the tray as shown. See diagram 20.

20

AR1275

5.7.4Place log (No. 7) along the LH side of the tray, log (No. 9) along the RH side of the tray and place logs (No. 8 and 11) along the front of the tray as shown. Place the cone (No. 14) on the LH side of the burnt log. See diagram 21.

21

AR1276

5.7.5Place the large log (No. 6) so that it rests on top of the rear and front logs to the LH side, Place log (No. 7) on the RH side and log (No. 8) so that it bridges the centre gap as shown. See diagram 22.

22

5.7.2Place the two logs (No.13) on top of the beads as shown. See diagram 19.

19

AR1277

AR1274

19

Image 19
Contents Aspen, Chamonix & Tahoe Decorative Gas Basket Fires Contents Flue Check Pass Fail Appliance Commissioning ChecklistGAS Check Turning the Appliance OFF User InstructionsGeneral Lighting the ApplianceUpgrading Your Fire Cleaning the FireArrangement of Fuel BED Components Coal & Pebble Layout Small Aspen & Chamonix Coal & Pebble Layout Tahoe Coal & Pebble Layout Medium Chamonix, Large Aspen & ChamonixLog & Driftwood Layout Small Aspen & Chamonix AR1276 Log & Driftwood Layout Tahoe Servicing Oxygen Depletion SensorFlame Failure Device RunningHigh Flue and Chimney Requirements Installation InstructionsInstallation of the GAS Supply Site RequirementsAppliance Location Control UpgradeUnpacking InstallationSafety Precautions InstallationArrangement of Fuel BED Components AR1265 AR1268 AR1277 AR1274 AR1278 AR1285 Commissioning CommissioningServicing Instructions Servicing / Fault Finding ChartsServicing Requirements Ignition Functional Check Ignition Functional CheckFlame Failure Functional Check Fault Finding ChartsFire Removal Replacing PartsIgnition Lead ODS Pilot Unit PiezoMain Injector Magnetic UnitPrimary Aeration Plate GAS Valve Engine Assembly Air Box Gasket Pilot Assembly DatabadgeChanging Between GAS Types LPG Gas Components Natural Gas ComponentsService Records Member of the Stovax Group