B-VENT SPECIFICS - MODEL GS50

CHIMNEY INSTALLATION

Three types of chimney systems may be used with this stove:

FIGURE 26

A CHIMNEY VENTING THIS STOVE SHALL NOT VENT

ANY SOLID FUEL BURNING APPLIANCE.

ALL HORIZONTAL RUNS MUST HAVE

A 1/4 INCH RISE PER FOOT.

FIGURE 27

ADAPTER

SPILL

SWITCH

INSTALLING 'B' VENT:

Follow the instructions for "Wall and Ceiling Protection".

ADAPTER INSTALLATION FIGURE 27

1.Remove the spill switch bracket from the rear of the adapter.

2.Gently pull the two wire terminals (located inside the 7" flue collar at the top of the stove) out approximately 8 inches.

3.Bring the wires through the lower hole in the adapter and out the spill switch opening. To pass the wires through the hole more easily, temporarily tape the two terminals to- gether.

4.With the spill switch opening aligned to the back of the stove, take hold of the adaptor base and push the crimped edge into the stove flue collar.

5.Connect the wire terminals to the spill switch and re- secure the bracket.

For aesthetics, the adapter has been designed to accept a standard matte black 7" stove pipe and the Napoleon decorative brass band (standard with the GS150KT). Both are available from your Napoleon dealer.

ADDING VENT SECTIONS

For ease of assembly, a 7" telescoping stove pipe may be installed over the 4" vent connection of the adapter. Add vent sections, twist locking (clockwise) securely, to the required height. The vent should ex- tend, at least, 3 feet above its point of contact with the roof and, at least, 2 feet higher than any wall, roof or building within 10 feet. FIGURE 28. (This is a guideline only; local vent- ing codes should be followed which may differ in height and clearance re- quirements.)

FIGURE 28

W415-0098 / A / 08.07.03

Image 12 Contents
GAS-FIRED Stoves Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCare of GLASS, and Plated Parts Location & Clearances GDS50 and GS50Direct Vent Specifics Model GDS50 Venting Lengths AIR Terminal LocationsAIR Terminal Installations Offset Installation Example Special Installation ExampleHorizontal Horizontal Installation Vertical Installation Wall and Ceiling ProtectionW415-0098 / a Continue with Gas Installation Stove Vent Connection Mobile Home InstallationChimney Installation Installing B VentVent Specifics Model GS50 Adding Vent SectionsInstalling Flashing Storm Collar Vent AdaptationsCombustion AIR TWO Screws Must be RE-SECURED. FigureGAS Installation Trivet Installation FinishingDoor Opening and Closing Mantle ClearanceLOG Placement Operation / Maintenance Spill SwitchTurbo Burner Operation Maintenance Operating InstructionsFor Your Safety Read Before Lighting Replacement Blower Installation BlowAdjustments Pilot Burner AdjustmentVenturi Adjustment Front Burner Rear BurnerReplacements # DescriptionPage Trouble Shooting Guide Symptom Problem Test SolutionModel GDS50 only