Multi Tech Equipment MLT20DCA6 operation manual TB1 Z

Page 51

WIRING DIAGRAM (mlt20dca6)

A

GREEN 16 AWG

T-BAR ASSEMBLY

P/N 49721

 

 

 

 

 

 

 

 

 

WHT

 

J1

J2

 

 

J3

J4

 

J5

J6

(LAMP 1)

(LAMP 2)

(LAMP 3)

(LAMP 4)

(LAMP 5)

(LAMP 6)

BLK

WHT

RED

WHT

BLUE

WHT

YEL

WHT

ORG

PURPLE

T

 

U

 

V

 

W

 

X

Y

 

GRN

GRN

 

 

GRN

GRN

 

GRN

GRN

BA

C

D

E

F

G

 

 

 

 

 

 

 

10-WIRE COIL CORD

 

 

 

H

 

C1

 

P/N 49609

 

 

 

 

 

 

 

 

BLK 14 AWG

120V IN

BALLAST #1

24µF@480V

 

 

 

 

(LAMP 1)

 

 

 

 

 

CAPACITOR

 

 

 

 

 

 

 

 

 

 

 

 

NEU.

OUTPUT

 

 

 

 

 

 

 

 

 

 

N

BLK

 

 

 

 

 

 

 

 

 

 

6 LAMP BALLAST ASSEMBLY

RED 16 AWG

 

 

16 AWG

 

 

 

 

 

 

 

 

P/N 49785 (MLT20DCA6)

 

1

R1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A1

 

 

 

I

 

C2

 

 

 

 

 

 

 

 

 

 

 

RED 14 AWG

120V IN

BALLAST #2

24µF@480V

 

NOTES:

 

 

 

 

 

 

CAPACITOR

 

 

 

 

 

 

 

 

 

 

NEU.

OUTPUT

 

 

 

 

RESISTOR IS INTERNALLY

 

 

 

 

 

O

 

1

 

 

 

 

 

RED

INSTALLED WITHIN THE CAPACITOR.

 

 

 

RED 16 AWG

 

16 AWG

 

 

 

 

 

 

 

 

 

 

NEUTRAL BUS

 

 

 

 

 

 

 

 

TB1 Z

 

 

 

J

 

C3

 

 

 

BLUE 14 AWG

 

 

 

 

 

WHT 14 AWG

 

120V IN

BALLAST #3

24µF@480V

 

 

 

 

 

 

 

 

YEL

 

CAPACITOR

 

 

 

 

 

NEU.

OUTPUT

 

 

 

 

 

 

 

 

WHT 14 AWG

 

 

 

 

 

 

P

 

 

 

 

 

 

 

BLUE

 

 

 

 

 

RED 16 AWG

 

16 AWG

WHT 14 AWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL 16 AWG

 

 

 

 

K

 

C4

 

 

 

YELLOW 14 AWG

 

 

 

 

 

YEL 16 AWG

 

120V IN

BALLAST #4

24µF@480V

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITOR

 

 

 

 

 

NEU.

OUTPUT

 

Q

 

YEL 16 AWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED 16 AWGYEL 16 AWG

YEL 16 AWG

 

 

 

 

 

L

 

 

 

 

C5

 

 

 

BLK 14 AWG

 

BALLAST #5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120V IN

 

24µF@480V

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITOR

 

 

 

 

 

NEU. OUTPUT

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED 16 AWG

 

 

 

 

 

 

 

 

 

 

ORG 16 AWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL 16 AWG

 

 

 

 

 

 

 

 

 

 

C6

 

 

 

 

 

 

M

 

 

 

 

 

 

 

BLK 14 AWG

 

BALLAST #6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120V IN

 

24µF@480V

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITOR

 

 

 

 

 

NEU. OUTPUT

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED 16 AWG

PURPLE 16 AWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL 16 AWG

WHITE 10 AWG

HA

AI

WHITE 10 AWG

MLT20 SERIES LIGHT TOWER • operation manual — rev. #0 (01/18/13) — page 51

Image 51
Contents Models Proposition 65 warning Nhtsa Reporting Safety DefectsSpecifications are subject to change without notice Table of ContentsAddresses practices not related to personal injury Safety InformationSaFeTY Messages SaFeTY sYMBOLsGeneRaL saFeTY LaMp saFeTY LIgHT TOWeR saFeTYTOWIng saFeTY Loading and Tie-Down on Flatbed Truck TRanspORTIng saFeTY„ neveR operate light tower ELeCTRICaL saFeTYMLT20 Series Specifications Light Tower SpecificationsGenerator/Engine Specifications Length Mast Stowed Position Length Mast Deployed Position DimensionsDimensions Reference Letter Description DimensionMetal Halide Lamps General informationMajor Components Control Panel Side ComponentsMajor Components Front/Rear Circuit Breakers Turn the lamps on and offCheck all fastening nuts and bolts for tightness Read all safety instructions at the beginning of manualInspection Before startingFemale and Male Connector Contact between the two connectorsOutriggers and Support Stands OperationStarting the Engine Mast operationRaising the Mast Rotating the Mast Raising the MastLowering the Mast Stowing the Mast to Horizontal PositionVoltage Regulator Knob and AC Voltmeter Servicing the Mast Raise/Lower Cable System MaintenanceGenerator/ENGINE Maintenance Check Cable WearLower the mast to the horizontal resting position Servicing the Mast Extension Cable SystemHydraulic Brakes Maintenance TrailersManually Adjusting the Brakes Trailer BrakesHydraulic Brake Troubleshooting Adjustable ChannelLeaf Suspension Wheel Hub AdjustmentSafety guidelines Trailers COMMOn Causes for LOss of TRaILeRTRaILeR TOWIng guIDeLInes COupLIng to THe TOW veHICLe DRIvIng COnDITIOnsInOpeRaBLe BRaKes, LIgHTs or MIRRORs TRaILeR TOWIng TIpsTRaILeR vIn Tag BRaKe COnTROLLeR ELeCTRICaL COnneCTORTOW veHICLe SuspensIOn sYsTeMJaCKsTanD SaFeTY CHaInsTRaILeR LIgHTIng anD BRaKIng COnneCTOR BReaKaWaY sYsTeMLock washer and hitch frame Trailer tongue. Wood or concrete blocks may also be usedCoupling the Trailer to the Tow vehicle Ball Coupler Attaching safety Chain Breakaway Brake systemBreakaway Cable surge Brake system Pintle Coupler and pintle Hook Connecting Trailer LightsUncoupling the Ball Hitch PInTLe Hitch COupLeRCoupling Trailer to Tow vehicle pintle Coupler Figure H. Attaching Safety Chain Pintle HitchTIRe saFeTY Unsafe Tires, Lug nuts or Wheels Determining Load Limit of TrailerBe sure lug nuts are tight before each tow Determining Load Limit of Tow vehicle step StepTIRe FunDaMenTaLs Table a. speed RatingLetter Rating Speed Rating Uniform Tire Quality grading standards uTQgs Tire safety TipsTire Repair Replacing Worn or Damaged TiresLug nut Torque Requirements Table B. Tire Wear TroubleshootingWheel Rims Wheels, Bearings and Lug nutsTable C. Tire Torque Requirements Lights and signalsSymptom Possible Cause Solution Lamp TroubleshootingLamp starts slowly ARC does not strike Defective Lamp? When switch is first Checking voltage and ballast Turned onReplacement minimizes color differences Clean fixtureBallast Removal Lamp Troubleshooting GuideConnections StartingPage Electronic Component Locator mlt20dca Reference MLT20DCA 4-lamp wiring diagram on succeeding pagesElectronic Component Locator mlt20dca6 Wiring Diagram mlt20dca TB1 N Wiring Diagram mlt20dca6 TB1 Z HERE’S HOW to GET Help

MLT20DCA6, MLT20DCA specifications

The Multi Tech Equipment MLT20DCA and MLT20DCA6 stand out in the realm of compact construction machinery, renowned for their versatility and efficiency. These models are designed to meet the demanding needs of various industries, including construction, landscaping, and agricultural operations.

One of the key features of the MLT20DCA series is its powerful and reliable engine. Equipped with a robust diesel engine, these machines deliver optimal performance and fuel efficiency, ensuring that operators can complete tasks quickly and economically. This powertrain is complemented by a highly responsive hydraulic system, which allows for seamless operation of attachments such as buckets, forks, and augers.

The ergonomic design of the MLT20DCA and MLT20DCA6 enhances operator comfort and productivity. The spacious cabin is equipped with intuitive controls and offers excellent visibility, making it easier for operators to navigate tight spaces and perform intricate tasks. The low center of gravity provides stability and balance, which is essential when working on uneven terrain.

Both models feature a compact design, making them ideal for urban environments and confined job sites. Their versatile lifting capabilities allow them to handle a wide range of materials, from heavy loads to delicate items, making them invaluable in various applications. The MLT20DCA6 variant offers additional lifting height and capacity, catering to heavier-duty operations.

Safety is a paramount concern in equipment design, and the MLT20DCA series does not disappoint. These machines are equipped with multiple safety features, including reinforced ROPS (Roll Over Protective Structure), safety interlocks, and improved braking systems. This ensures the well-being of operators and those working in proximity.

In terms of technology, Multi Tech has integrated advanced control systems into both models. This includes automated diagnostics that monitor machine performance and alert users to potential issues before they become significant problems. Connectivity features also allow for remote monitoring, enhancing fleet management capabilities.

In summary, the Multi Tech Equipment MLT20DCA and MLT20DCA6 represent a formidable option for professionals seeking reliable and efficient compact machinery. With their powerhouse engines, user-friendly design, and advanced safety and technology features, these machines are poised to enhance productivity across various applications, ensuring a strong return on investment for operators.