Installing the unit

IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes.

Upon receipt, inspect the product to verify that it has not been damaged during transport.

If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer.)

After completing the installation, always carry out a functional test and provide the instructions on how to operate the air conditioner to the user.

Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires, explosions or injuries.

To prevent injury when accidentally touching the indoor unit fan, install the indoor unit at least 2.5m above the floor.

The air conditioner should be used only for the applications for which it has been designed : the indoor unit is not suitable to be installed in areas used for laundry.

Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs. The units’components must be accessible and that can be disassembled in conditions of complete safety either for people or things.

For this reason, where it is not observed as indicated into the Installation Manual, the cost necessary to reach and repair the unit (in safety, as required by current regulations in force) with slings, trucks, scaffolding or any other means of elevation won’t be considered in-warranty and charged to end user.

Power supply line, fuse or circuit breaker

Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in compliance with current local safety standards.

Always verify that a suitable grounding connection is available.

Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines.

Always verify that the cut-off and protection switches are suitably dimensioned.

Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual.

Always verify that electric connections (cable entry, section of leads, protections…) are compliant with the electric specifications and with the instructions provided in the wiring scheme.

Always verify that all connections comply with the standards applicable to the installation of air conditioners.

Choosing the installation location

Indoor unit

Where airflow is not blocked

Where cool air can be distributed throughout the room

Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram

Wall that prevents vibration and is strong enough to hold the product weight

Out of the direct sunlight

1m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)

As far away as possible from the fluorescent and incandescent lights (so that the remote controller can be operated well)

A place where the air filter can be replaced easily

23

ENGLISH

Boracay EUR_AQ09T&U@_IBIM_32447A_EN-4.indd 23

2015/7/7 14:56:34

Image 23
Contents Boracay EURAQ09T&U@IBIM32447AEN-4.indd 2015/7/7 Contents Wall socket Safety precautionsImportant safety symbols and precautions Follow directionsFor Using For Cleaning Operation ranges Checking before useDisplay  09/12/18/24T PowerChecking the name of the parts Main parts  09/12/18/24T Remote controller buttons Checking the remote controllerIndicator Remote controller displayBattery changing time Storing the remote controllerBasic function Low Med High AutoAuto Low Med High Vertical air flow Adjusting the air flow directionUsing the Turbo function Press the Air swing button on the remote controllerPress the Time Up or Time Down button to set the time When the air conditioner is on and in cool/heat modePress the button on the remote controller ModeAdditional options available in On timer mode Setting the On/Off timerPress the On Timer/Off Timer button Turn off automatically Using the Smart Saver functionFrom the moment you have set the timer If the air conditioner is on If the air conditioner is off09/12/18/24T 09/12/18/24U Using the Auto Clean functionWhen the air conditioner is turned on Opening the panel Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerDry the Air filter in a ventilated area Cleaning the air filterRemoving the Air filter Open the panel and put the Air filter outPeriodical checks Maintaining the air conditionerTroubleshooting Connection Outdoor unit Heat exchanger during Heat mode in winterFlow movement changes. It is normal General information  a place where the air filter can be replaced easily Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerModel Where sulfide gas existsOutdoor Unit Top view Side view When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Tools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the cable Connecting the assembly cableCable specification Each wire is labeled with the corresponding terminal number Cut off the remaining foam insulation Smooth the cut edgesTorque Put a flare nut slightly into the pipe and modify the flare Purging the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeDitch Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined CrackedDrain hose installation Outer Torque Purging the connected pipesConnect a drain hose to the drain plug Ensure that condensation draining is adequateIf you use a pipe shorter than 5m Gas service port as seen in the pictureAdding Refrigerant If you use a pipe longer than 5m1975 Please fill in with indelible ink the factory refrigerant charge of the product Leak test after opening valves Performing the gas leak testsTightening torque To check for gas leaks on the outdoor unitFixing the outdoor unit in place Then place the indoor unit on the installation plateFixing the indoor unit in place Final Check and Trial Operation Insulation tape to finish How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withMemo Questions or COMMENTS? Thank you for purchasing this Samsung product Air Conditioner
Related manuals
Manual 43 pages 7.84 Kb Manual 21 pages 37.46 Kb Manual 43 pages 50.34 Kb Manual 43 pages 54.35 Kb Manual 41 pages 57.34 Kb Manual 43 pages 47.11 Kb Manual 41 pages 21.89 Kb Manual 21 pages 33.89 Kb Manual 43 pages 57.8 Kb Manual 39 pages 24.04 Kb Manual 41 pages 16.8 Kb Manual 41 pages 21.55 Kb Manual 21 pages 17.82 Kb Manual 40 pages 16.42 Kb Manual 41 pages 7.22 Kb Manual 41 pages 49.92 Kb Manual 41 pages 32.45 Kb Manual 41 pages 26.36 Kb Manual 41 pages 36.71 Kb Manual 41 pages 46.99 Kb Manual 41 pages 14.18 Kb Manual 41 pages 8.52 Kb

AQ24TSBXCEE, AQ18TSBXCEE, AQ12UGFNEUR, AQ12TSBN, AQ09UGFN specifications

The Samsung AQ09TSBN is a standout model in the realm of air conditioning units, encapsulating advanced features and technologies aimed at delivering superior indoor comfort. This compact yet powerful unit is designed for both residential and small commercial applications, ensuring an optimal climate control experience.

One of the primary characteristics of the AQ09TSBN is its energy efficiency. This air conditioner boasts an impressive Energy Efficiency Ratio (EER), helping to reduce electricity consumption while maintaining a consistent and comfortable temperature. This is particularly beneficial for users who prioritize sustainability and cost savings on their energy bills.

The unit comes equipped with Samsung's innovative Wind-Free cooling technology, which eliminates the harsh cold drafts typically associated with traditional air conditioning systems. Instead, it provides a gentle, diffused airflow that evenly distributes cool air throughout the room. This feature not only enhances comfort but also ensures that the air remains in motion without the discomfort of direct cold air, making it ideal for prolonged use.

Samsung's SmartThings integration allows users to remotely control the AQ09TSBN through a smartphone app. This smart technology enables the scheduling of cooling times, temperature adjustments, and energy monitoring, giving users the flexibility to manage their climate control needs from virtually anywhere. Additionally, voice command functionality through compatible smart devices offers an extra layer of convenience.

The AQ09TSBN is also designed with advanced filtration technology that captures dust, allergens, and other airborne particles, promoting a cleaner and healthier indoor environment. The easy-to-remove and washable filters ensure that maintenance is both simple and efficient, allowing users to keep the unit operating at peak performance.

Moreover, the air conditioner features a sleek, modern design that seamlessly fits into various interior styles. Its quiet operation allows for minimal disruption, whether in a bedroom or an office setting, further enhancing its appeal for users seeking tranquility alongside comfort.

In summary, the Samsung AQ09TSBN represents a fusion of energy efficiency, advanced technology, and user-friendly features, making it an excellent choice for individuals and businesses looking to maintain a pleasant indoor climate. With its commitment to performance and innovation, this air conditioning unit continues to lead the way in modern climate control solutions.