Samsung AQ24TSBNEUR, AQ24TSBXEUR manual Checking the remote controller, Remote controller buttons

Page 8

Checking the remote controller

Point the remote controller towards the remote controller receiver of the indoor unit.

When you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator() appears on the remote controller display.

Remote controller buttons

Remote controller display

Smart Saver

Less energy usage makes your space cool between the temperature range of 24°C~30°C.

Turbo

Operate in auto fan speed to cool quickly.

Quiet

(Has no this function)

Temp + -

Increase/Decrease the temperature by 1˚C.

Set themode on.

On Timer

Set the On Timer on.

Off Timer

Set the Off Timer on.

Time Up/Time Down

Adjust the time for timer/ mode.

This button doesn't have any function.

Power

Turn on/off the air conditioner.

Mode

Set one of the 5 operating modes (see pages 10-11 for instructions).

Auto Clean

Auto clean function – Dry inside of the indoor unit to get rid of odor.

Air swing

Activate/Deactivate air flow blade movement automatically up and down.

Fan

 

Adjust how much air flows through the air conditioner with the 4 different fan speeds such as Auto/Low/Medium/High.

Set

Set the timer/

mode.

Cancel

 

Cancel the timer/

mode.

• Make sure that the water does not get to the remote controller.

8

Boracay EUR_AQ09T&U@_IBIM_32447A_EN-4.indd 8

2015/7/7 14:56:28

Image 8 Contents
Boracay EURAQ09T&U@IBIM32447AEN-4.indd 2015/7/7 Contents Safety precautions Important safety symbols and precautionsFollow directions Wall socketFor Using For Cleaning Checking before use Operation rangesPower Checking the name of the partsMain parts  09/12/18/24T  Display  09/12/18/24TChecking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller IndicatorBasic function Low Med High AutoAuto Low Med High Adjusting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowWhen the air conditioner is on and in cool/heat mode Press the button on the remote controllerMode Press the Time Up or Time Down button to set the timeAdditional options available in On timer mode Setting the On/Off timerPress the On Timer/Off Timer button Using the Smart Saver function From the moment you have set the timerIf the air conditioner is on If the air conditioner is off Turn off automatically09/12/18/24T 09/12/18/24U Using the Auto Clean functionWhen the air conditioner is turned on Cleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelCleaning the air filter Removing the Air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Connection Outdoor unit Heat exchanger during Heat mode in winterFlow movement changes. It is normal General information Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyModel Where sulfide gas existsOutdoor Unit When installing more than 1 outdoor unit When the air outlet is towards the wall Figure Description Top view Side viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsConnecting the cable Connecting the assembly cableCable specification Each wire is labeled with the corresponding terminal number Cut off the remaining foam insulation Smooth the cut edgesTorque Purging the indoor unit Cutting or extending the pipeUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flarePipe 50 Pa. The joint must be accessible and serviceable Correct InclinedCracked DitchDrain hose installation Purging the connected pipes Connect a drain hose to the drain plugEnsure that condensation draining is adequate Outer TorqueGas service port as seen in the picture Adding RefrigerantIf you use a pipe longer than 5m If you use a pipe shorter than 5m1975 Please fill in with indelible ink the factory refrigerant charge of the product Performing the gas leak tests Tightening torqueTo check for gas leaks on the outdoor unit Leak test after opening valvesFixing the outdoor unit in place Then place the indoor unit on the installation plateFixing the indoor unit in place Final Check and Trial Operation How to connect your extended power cables Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with Insulation tape to finishMemo Questions or COMMENTS? Air Conditioner Thank you for purchasing this Samsung product
Related manuals
Manual 43 pages 7.84 Kb Manual 21 pages 37.46 Kb Manual 43 pages 50.34 Kb Manual 43 pages 54.35 Kb Manual 41 pages 57.34 Kb Manual 43 pages 47.11 Kb Manual 41 pages 21.89 Kb Manual 21 pages 33.89 Kb Manual 43 pages 20.03 Kb Manual 43 pages 57.8 Kb Manual 39 pages 24.04 Kb Manual 41 pages 16.8 Kb Manual 41 pages 21.55 Kb Manual 21 pages 17.82 Kb Manual 40 pages 16.42 Kb Manual 41 pages 7.22 Kb Manual 41 pages 49.92 Kb Manual 41 pages 32.45 Kb Manual 41 pages 26.36 Kb Manual 41 pages 36.71 Kb Manual 41 pages 46.99 Kb Manual 41 pages 14.18 Kb Manual 41 pages 8.52 Kb