Samsung AQ18UGFN Adjusting the air flow direction, Using the Turbo function, Vertical air flow

Page 12

Adjusting the air flow direction

Air flow can be directed to your desired position.

Vertical air flow

Air flow blades move up and down.

Press the Air swingbutton on the remote controller.

Air swing indicator will be on and air flow blades move up and down continuously to circulate the air.

Press the Air swing button on the remote controller again, to keep the air flow direction in a constant position.

Horizontal air flow

Make sure one of the blade pin lever that stick out of the air flow blades are not broken.

Move the blade pin lever left or right to keep the air flow direction in a constant position you prefer.

• Be extremely careful with your fingers while adjusting the Horizontal air flow direction.

There is a potential risk of personal injury when the unit is

mishandled.

Blade pin lever

Using the Turbo function

Turbo function will be helpful to cool your room quickly and effectively.

Press the Turbo button on the remote controller during Cool mode.

Turbo indicator appears on the remote controller display and the air conditioner operates in Turbo function for 30 minutes.

Cancel Press the Turbo button once again.

• Turbo function is only available in Cool mode.

• If you press the Mode button while the Turbo function is on, it will cancel the function.

• Temperature/Fan speed cannot be adjusted while using this function.

12

Boracay EUR_AQ09T&U@_IBIM_32447A_E.indd 12

2011-3-19 10:07:42

Image 12
Contents Boracay EURAQ09T&U@IBIM32447AE.indd 2011-3-19 Contents Safety precautions Important safety symbols and precautionsFollow directions Wall socketFor Using For Cleaning Checking before use Operation rangesPower Checking the name of the partsMain parts  09/12/18/24T  Display  09/12/18/24TChecking the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller IndicatorBasic function Auto Auto Low Med HighLow Med High Adjusting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowWhen the air conditioner is on and in cool/heat mode Press the button on the remote controllerMode Press the Time Up or Time Down button to set the timeSetting the On/Off timer Press the On Timer/Off Timer buttonAdditional options available in On timer mode Using the Smart Saver function Combining On Timer and Off TimerUsing the Auto Clean function When the air conditioner is turned on09/12/18/24T 09/12/18/24U Cleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelCleaning the air filter Removing the Air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Outdoor unit Heat exchanger during Heat mode in winter Flow movement changes. It is normalConnection General information Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor UnitModel When installing more than 1 outdoor unit When the air outlet is towards the wall Figure Description Top view Side viewAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Each wire is labeled with the corresponding terminal number Smooth the cut edges Cut off the remaining foam insulationPurging the indoor unit Cutting or extending the pipeUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flarePipe 50 Pa. The joint must be accessible and serviceable Correct InclinedCracked Outer DiameterDrain hose installation Purging the connected pipes Connect a drain hose to the drain plugEnsure that condensation draining is adequate Adding Refrigerant Please fill in with indelible ink  the factory refrigerant charge of the product1975 Performing the gas leak tests To check for gas leaks on the outdoor unitTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesThen place the indoor unit on the installation plate Fixing the indoor unit in placeFixing the outdoor unit in place Final Check and Trial Operation How to connect your extended power cables Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with Insulation tape to finishMemo 42 27 7267864, € 0.07/min70 70 19 +381Air Conditioner
Related manuals
Manual 21 pages 37.46 Kb Manual 43 pages 50.34 Kb Manual 43 pages 54.35 Kb Manual 41 pages 57.34 Kb Manual 43 pages 47.11 Kb Manual 41 pages 21.89 Kb Manual 21 pages 33.89 Kb Manual 43 pages 20.03 Kb Manual 43 pages 57.8 Kb Manual 39 pages 24.04 Kb Manual 41 pages 16.8 Kb Manual 41 pages 21.55 Kb Manual 21 pages 17.82 Kb Manual 40 pages 16.42 Kb Manual 41 pages 7.22 Kb Manual 41 pages 49.92 Kb Manual 41 pages 32.45 Kb Manual 41 pages 26.36 Kb Manual 41 pages 36.71 Kb Manual 41 pages 46.99 Kb Manual 41 pages 14.18 Kb Manual 43 pages 51.4 Kb Manual 31 pages 36.44 Kb Manual 32 pages 17.61 Kb Manual 32 pages 60.27 Kb Manual 30 pages 51.71 Kb Manual 32 pages 35.17 Kb Manual 32 pages 6.86 Kb Manual 34 pages 7.54 Kb Manual 32 pages 51.3 Kb Manual 33 pages 37.87 Kb Manual 31 pages 55.87 Kb Manual 31 pages 51.06 Kb Manual 41 pages 8.52 Kb

AQ24TSBXCEE, AQ18TSBXCEE, AQ12UGFNEUR, AQ12TSBN, AQ09UGFN specifications

The Samsung AQ09TSBN is a standout model in the realm of air conditioning units, encapsulating advanced features and technologies aimed at delivering superior indoor comfort. This compact yet powerful unit is designed for both residential and small commercial applications, ensuring an optimal climate control experience.

One of the primary characteristics of the AQ09TSBN is its energy efficiency. This air conditioner boasts an impressive Energy Efficiency Ratio (EER), helping to reduce electricity consumption while maintaining a consistent and comfortable temperature. This is particularly beneficial for users who prioritize sustainability and cost savings on their energy bills.

The unit comes equipped with Samsung's innovative Wind-Free cooling technology, which eliminates the harsh cold drafts typically associated with traditional air conditioning systems. Instead, it provides a gentle, diffused airflow that evenly distributes cool air throughout the room. This feature not only enhances comfort but also ensures that the air remains in motion without the discomfort of direct cold air, making it ideal for prolonged use.

Samsung's SmartThings integration allows users to remotely control the AQ09TSBN through a smartphone app. This smart technology enables the scheduling of cooling times, temperature adjustments, and energy monitoring, giving users the flexibility to manage their climate control needs from virtually anywhere. Additionally, voice command functionality through compatible smart devices offers an extra layer of convenience.

The AQ09TSBN is also designed with advanced filtration technology that captures dust, allergens, and other airborne particles, promoting a cleaner and healthier indoor environment. The easy-to-remove and washable filters ensure that maintenance is both simple and efficient, allowing users to keep the unit operating at peak performance.

Moreover, the air conditioner features a sleek, modern design that seamlessly fits into various interior styles. Its quiet operation allows for minimal disruption, whether in a bedroom or an office setting, further enhancing its appeal for users seeking tranquility alongside comfort.

In summary, the Samsung AQ09TSBN represents a fusion of energy efficiency, advanced technology, and user-friendly features, making it an excellent choice for individuals and businesses looking to maintain a pleasant indoor climate. With its commitment to performance and innovation, this air conditioning unit continues to lead the way in modern climate control solutions.