Samsung AQ12UGFXEUR, AQ18UGAN Purging the connected pipes, Connect a drain hose to the drain plug

Page 34

Installing and connecting the drain hose of the outdoor unit

While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate

draining, do the following:

1. Insert the drain plug into the drain hole on the underside of the outdoor unit.

• To avoid drain plug from contacting the ground, secure gap between the ground and the bottom surface of the outdoor unit.

Drain hole

Drain plug

2.

Connect a drain hose to the drain plug.

Bottom surface of outdoor unit

 

 

Drain hole

 

 

 

Drain plug

Drain hose

3.

Ensure that condensation draining is adequate.

 

Snow-proof hood

 

 

 

• In areas with heavy snow fall, piled snow could block the air intake.

To avoid this incident, install a frame that is higher than estimated snow

fall. In addition, install a snow-proof hood to avoid snow from piling on the

Estimated

outdoor unit.

snow fall Frame

 

 

Ground

Purging the connected pipes

The outdoor unit is loaded with sufficient R410A refrigerant. Do not vent R410A into atmosphere: it is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 1975.

You should purge the air in the indoor unit and in the pipe. If air remains in the refrigerant pipes, it affects the compressor. It may cause reduction of cooling capacity and malfunction. Refrigerant for air purging is not charged in the outdoor unit. Use Vacuum Pump as seen in the picture.

• When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first

before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle

abnormally high. It may cause explosion and injury.

1.Connect each assembly pipe to the appropriate valve on the outdoor unit and tighten the flare nut.

2.Tighten the flare nut first with your hands, and then with a torque wrench, applying the following torque:

• Excessive torque can be cause of gas leakage.

• Make the electrical connection and leave the system into“stand by mode”. Do not turn on the system!

This is necessary for better vacuum operation (full OPEN position of Electronic Expansion Valve - EEV -).

Outdoor unit

Indoor unit

 

Gas pipe side

 

Liquid pipe side

Outer Diameter

Torque (kgf•cm)

ø6.35 mm

140~170

ø9.52 mm

250~280

ø12.70 mm

380~420

ø15.88 mm

440~480

ø19.05 mm

990~1210

ø22.23 mm

990~1210

34

Boracay EUR_AQ09T&U@_IBIM_32447A_E.indd 34

2011-3-19 10:08:20

Image 34
Contents Boracay EURAQ09T&U@IBIM32447AE.indd 2011-3-19 Contents Follow directions Safety precautionsImportant safety symbols and precautions Wall socketFor Using For Cleaning Checking before use Operation rangesMain parts  09/12/18/24T  PowerChecking the name of the parts Display  09/12/18/24TChecking the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time IndicatorBasic function Auto Low Med High AutoLow Med High Press the Air swing button on the remote controller Adjusting the air flow directionUsing the Turbo function Vertical air flowMode When the air conditioner is on and in cool/heat modePress the button on the remote controller Press the Time Up or Time Down button to set the timePress the On Timer/Off Timer button Setting the On/Off timerAdditional options available in On timer mode Using the Smart Saver function Combining On Timer and Off TimerWhen the air conditioner is turned on Using the Auto Clean function09/12/18/24T 09/12/18/24U Cleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit Opening the panelOpen the panel and put the Air filter out Cleaning the air filterRemoving the Air filter Dry the Air filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Flow movement changes. It is normal Outdoor unit Heat exchanger during Heat mode in winterConnection General information Power supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit  a place where the air filter can be replaced easilyOutdoor Unit Where sulfide gas existsModel  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall Top view Side viewAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Each wire is labeled with the corresponding terminal number Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Purging the indoor unitCutting or extending the pipe Put a flare nut slightly into the pipe and modify the flareCracked Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined Outer DiameterDrain hose installation Connect a drain hose to the drain plug Purging the connected pipesEnsure that condensation draining is adequate Adding Refrigerant  the factory refrigerant charge of the product Please fill in with indelible ink1975 To check for gas leaks on the indoor unit Performing the gas leak testsTo check for gas leaks on the outdoor unit Leak test with nitrogen before opening valvesFixing the indoor unit in place Then place the indoor unit on the installation plateFixing the outdoor unit in place Final Check and Trial Operation After tube contraction work is completed, wrap it with How to connect your extended power cablesApply heat to the contraction tube to contract it Insulation tape to finishMemo 70 70 19 42 277267864, € 0.07/min +381Air Conditioner
Related manuals
Manual 21 pages 37.46 Kb Manual 43 pages 50.34 Kb Manual 43 pages 54.35 Kb Manual 41 pages 57.34 Kb Manual 43 pages 47.11 Kb Manual 41 pages 21.89 Kb Manual 21 pages 33.89 Kb Manual 43 pages 20.03 Kb Manual 43 pages 57.8 Kb Manual 39 pages 24.04 Kb Manual 41 pages 16.8 Kb Manual 41 pages 21.55 Kb Manual 21 pages 17.82 Kb Manual 40 pages 16.42 Kb Manual 41 pages 7.22 Kb Manual 41 pages 49.92 Kb Manual 41 pages 32.45 Kb Manual 41 pages 26.36 Kb Manual 41 pages 36.71 Kb Manual 41 pages 46.99 Kb Manual 41 pages 14.18 Kb Manual 43 pages 51.4 Kb Manual 31 pages 36.44 Kb Manual 32 pages 17.61 Kb Manual 32 pages 60.27 Kb Manual 30 pages 51.71 Kb Manual 32 pages 35.17 Kb Manual 32 pages 6.86 Kb Manual 34 pages 7.54 Kb Manual 32 pages 51.3 Kb Manual 33 pages 37.87 Kb Manual 31 pages 55.87 Kb Manual 31 pages 51.06 Kb Manual 41 pages 8.52 Kb

AQ24TSBXCEE, AQ18TSBXCEE, AQ12UGFNEUR, AQ12TSBN, AQ09UGFN specifications

The Samsung AQ09TSBN is a standout model in the realm of air conditioning units, encapsulating advanced features and technologies aimed at delivering superior indoor comfort. This compact yet powerful unit is designed for both residential and small commercial applications, ensuring an optimal climate control experience.

One of the primary characteristics of the AQ09TSBN is its energy efficiency. This air conditioner boasts an impressive Energy Efficiency Ratio (EER), helping to reduce electricity consumption while maintaining a consistent and comfortable temperature. This is particularly beneficial for users who prioritize sustainability and cost savings on their energy bills.

The unit comes equipped with Samsung's innovative Wind-Free cooling technology, which eliminates the harsh cold drafts typically associated with traditional air conditioning systems. Instead, it provides a gentle, diffused airflow that evenly distributes cool air throughout the room. This feature not only enhances comfort but also ensures that the air remains in motion without the discomfort of direct cold air, making it ideal for prolonged use.

Samsung's SmartThings integration allows users to remotely control the AQ09TSBN through a smartphone app. This smart technology enables the scheduling of cooling times, temperature adjustments, and energy monitoring, giving users the flexibility to manage their climate control needs from virtually anywhere. Additionally, voice command functionality through compatible smart devices offers an extra layer of convenience.

The AQ09TSBN is also designed with advanced filtration technology that captures dust, allergens, and other airborne particles, promoting a cleaner and healthier indoor environment. The easy-to-remove and washable filters ensure that maintenance is both simple and efficient, allowing users to keep the unit operating at peak performance.

Moreover, the air conditioner features a sleek, modern design that seamlessly fits into various interior styles. Its quiet operation allows for minimal disruption, whether in a bedroom or an office setting, further enhancing its appeal for users seeking tranquility alongside comfort.

In summary, the Samsung AQ09TSBN represents a fusion of energy efficiency, advanced technology, and user-friendly features, making it an excellent choice for individuals and businesses looking to maintain a pleasant indoor climate. With its commitment to performance and innovation, this air conditioning unit continues to lead the way in modern climate control solutions.