Samsung SMO-150QPV, SMO-150QP/UMG manual English-50, Observation Monitor

Page 50

OBSERVATION MONITOR

Video Input

CAMERA 8 Input : 1.0Vp-p (CVBS), 75

 

VCR 1 Input : 1.0Vp-p, 75

Video Output

BNC 4 Output : 1.0 Vp-p, 75, CVBS

 

VCR 1 Output : 1.0 Vp-p, 75, CVBS

 

 

 

Voice Input

CAMERA 8 Input

 

VCR 1 Input

Voice Output

TALK 4 Output(CH 1, 2, 3, 4)

 

VCR 1 Output

 

 

Alarm/Motion Features:

A/O (HOT, COLD) : Relay Active

Connected to Alarm

A/R (Alarm Reset) : Open Collector “L” Level,

Box/Camera

 

Pulse Width = 150ms or above

 

Alarm Hold Time : Select 5 sec, 15 sec, 30 sec, 1 min, 3 min,

 

 

5 min, 10 min, 20 min, 30 min.

 

 

Sequence

Select between 01 sec to 30 sec.

Event List

(max) 64 case

 

 

Display mode

Single mode, Quad-A mode, Quad-B mode, PIP, Sequence

 

Freeze, Zoom (X2)

 

 

Horizontal Resolution

350 TV Lines or more (Live Mode Full Screen)

Operation Temperature

0 °C ~ 40 °C

CRT

SMO-150QP : 15" FLAT CRT

Dimension (W x D x H (mm))

15" : (MONITOR) 388 X 459 X 379, (PACKING) 462 X 543 X 613

 

 

Weight

15" : (MONITOR) 15.2Kg, (PACKING) 22Kg

 

 

Power consumption

110W

 

 

High Voltage (KV)

28 ±2.0

Operation Humidity Range

0 ~ 90%

 

 

AC Input Ranges

Control range of main section 100V~250V or “Indicated on the rear of the

 

MONITOR set”

Audio Output[watt]

1.5W

English-50

Image 50
Contents SMO-150QP Important Safety Instructions Graphic Symbol Explanation Important Safeguards Page Page User-Installer Caution FCC & Ices InformationInformation to user IC Compliance Notice Contents Setting each item function at Setup Menu English-11English-12 System Components and InstallationEnvironmental requirements for installation and safety System Components English-13Camera composition and installation method English-14Sensor jack Installing Syandard Camera SOC-C120PEnglish-15 Speaker➁ Fresnel Lens English-16PIR Camera composition Top Bottom ① Lens ➃ 5-Pin Terminal Block English-17➂ 6-pin modular jack English-18 ➅ PIR Sensor ⑤ Function SwitchEnglish-19 ⑦ MicrophoneCamera installation Hints English-20Installing the PIR Camera SOC-C321P English-21English-22 English-23 Installing the Camera using the Mount-Corner English-24English-25 English-26 English-27 Installation English-28Installation Wall or Ceiling English-29English-30 Camera Composition and Connecting Method toMonitor Connection status checking methodVCR or Alarm terminal connecting method External terminal connecting method for CameraExternal terminal connecting method for Camera English-31Whole System connection and configuration English-32AUD/SP SEL KEY Monitor Front Panel KEY Function and Using MethodTalk KEY VOL+/VOL- KEYQUAD/PAGE- KEY Power SAVE- KEYAlarm RESET- KEY LIVE/VCR- KEYFREEZE- KEY POWER- KEYPIP- KEY SEQUENCE- KEYMENU- KEY ŒENTER√ Switch using method at Menu settingENTER- KEY English-36English-37 Setting each item function at Setup MenuAdjust Menu function and setting method Setting method of date display format DATE/TIME Menu Function settingDwell Time Menu function setting Date and current time setting methodDisplay Menu function setting English-39Title Menu Function setting English-40Alarm Menu Function setting English-41View Event LOG Menu function and setting method English-42English-43 Display Mode setting methodSingle Screen Display Quad Mode Display English-44Auto Sequential Display Mode English-45PIP Mode Display English-46Zoom Mode Display English-47SOC-C120P Standard Camera Each product featureEnglish-48 English-49 SOC-C321P PIR CameraEnglish-50 Observation MonitorMemo English-51