3-6) ALARM MENU Function setting

•Function: Allows users to set the ALARM MODE for each camera.

•Setting method: Move to #6. ALARM MENU by using œENTER√ SWITCH at SETUP MENU, and press the ENTER SWITCH to display the OSD as shown in the figure below. (The figure shows the initial setting status.)

06/01/03

 

13:14:00

 

ALARM

SETTING

 

 

CAM1

 

ON

 

CAM2

 

ON

 

CAM3

 

ON

 

CAM4

 

ON

 

CAM5

 

ON

 

CAM6

 

ON

 

CAM7

 

ON

 

CAM8

 

ON

 

HOLD TIME

 

05SEC

 

ALARM ON TIME

00:00

 

ALARM OFF TIME

00:00

 

BUZZER

 

ON

(1)CAM1 to CAM8 item sets whether the alarm sensor connected to the camera is used or not. (ON: Alarm function setting, OFF: Alarm function canceling)

(2)HOLD TIME item sets time to freeze alarm operation when alarm occuring. (HOLD TIME to be set: 05SEC ~ 1MIN ~ 30MIN)

(3)ALARM ON/OFF TIME item sets beginning time (ON) and end time (OFF) that monitor recognizes alarm operation as alarm event.

*Note :Even if CAMERA ALARM is set to ON, alarm operation is not carried at time band except pre-set ALARM ON/OFF TIME.

(4)BUZZER item sets whether or not buzzer device set in monitor is used at an ALARM or LOSS occurring.

(ON: Buzzer operation, OFF: NA)

English-41

Image 41
Contents SMO-150QP Important Safety Instructions Graphic Symbol Explanation Important Safeguards Page Page FCC & Ices Information User-Installer CautionInformation to user IC Compliance Notice Contents English-11 Setting each item function at Setup MenuEnglish-12 System Components and InstallationEnvironmental requirements for installation and safety English-13 System ComponentsEnglish-14 Camera composition and installation methodEnglish-15 Installing Syandard Camera SOC-C120PSensor jack Speaker➁ Fresnel Lens English-16PIR Camera composition Top Bottom ① Lens ➃ 5-Pin Terminal Block English-17➂ 6-pin modular jack English-18 English-19 ⑤ Function Switch➅ PIR Sensor ⑦ MicrophoneEnglish-20 Camera installation HintsEnglish-21 Installing the PIR Camera SOC-C321PEnglish-22 English-23 English-24 Installing the Camera using the Mount-CornerEnglish-25 English-26 English-27 English-28 InstallationEnglish-29 Installation Wall or CeilingMonitor Camera Composition and Connecting Method toEnglish-30 Connection status checking methodExternal terminal connecting method for Camera External terminal connecting method for CameraVCR or Alarm terminal connecting method English-31English-32 Whole System connection and configurationTalk KEY Monitor Front Panel KEY Function and Using MethodAUD/SP SEL KEY VOL+/VOL- KEYAlarm RESET- KEY Power SAVE- KEYQUAD/PAGE- KEY LIVE/VCR- KEYPIP- KEY POWER- KEYFREEZE- KEY SEQUENCE- KEYENTER- KEY ŒENTER√ Switch using method at Menu settingMENU- KEY English-36English-37 Setting each item function at Setup MenuAdjust Menu function and setting method Dwell Time Menu function setting DATE/TIME Menu Function settingSetting method of date display format Date and current time setting methodEnglish-39 Display Menu function settingEnglish-40 Title Menu Function settingEnglish-41 Alarm Menu Function settingEnglish-42 View Event LOG Menu function and setting methodEnglish-43 Display Mode setting methodSingle Screen Display English-44 Quad Mode DisplayEnglish-45 Auto Sequential Display ModeEnglish-46 PIP Mode DisplayEnglish-47 Zoom Mode DisplaySOC-C120P Standard Camera Each product featureEnglish-48 SOC-C321P PIR Camera English-49Observation Monitor English-50English-51 Memo