Kohler K-10104, K-10103 manual Troubleshooting, Complete the Installation

Page 10

Complete the Installation (cont.)

Place the handle in the vertical position, as shown.

Rotate the handle clockwise, then reposition the handle at the 2 o’clock position.

For hot and cold water supply installations: Rotate the handle as

needed to achieve the desired water temperature.

For tempered or filtered water installations: Turn the handle

counterclockwise to the full cold position.

Secure the cover and handle to the valve with two screws (provided).

7. Troubleshooting

Symptoms

Probable

Recommended Action

 

Causes

 

 

1. No water

A.

There is a

A.

Remove the valve cover and

flow.

 

loose

 

check the connections from the

 

 

connection.

 

battery to the solenoid and

 

 

 

 

from the battery holder to the

 

 

 

 

sensor. Make sure that the

 

 

 

 

connector arrows are aligned

 

 

 

 

and that the connection is

 

 

 

 

secure.

 

B.

The

B.

Confirm the supply stops are in

 

 

supply

 

the ONposition.

 

 

stops are

 

 

 

 

in the

 

 

 

 

OFF

 

 

 

 

position.

 

 

 

C.

The

C. Remove the cover and inspect

 

 

wires/cables

 

the wires/cables for cuts or

 

 

are

 

damage. If the wires are cut or

 

 

pinched or

 

damaged, order a new

 

 

damaged.

 

solenoid, sensor assembly,

 

 

 

 

sensor extension cable, or

 

 

 

 

battery holder. Do not pinch or

 

 

 

 

damage the wires during

 

 

 

 

reassembly.

 

 

 

 

 

1056542-2-B

10

Kohler Co.

Image 10
Contents Installation Guide Tools and Materials Thank You For Choosing Kohler CompanyBefore You Begin Before You Begin Install the Faucet Convert to Tempered or Filtered Water OptionalMount the Valve Body Assembly Install the Battery Connect with the arrows pointing toward each otherConnect the Supplies Connect the Supplies Check for Leaks Complete the InstallationInstall the Cover and Handle Secure the Hoses and Sensor CableFor tempered or filtered water installations Turn the handle TroubleshootingComplete the Installation Symptoms Probable Recommended Action CausesTroubleshooting Troubleshooting Troubleshooting Merci d’avoir choisi la compagnie Kohler Outils et matérielsAvant de commencer Avant de commencer Kohler Co Français-2 1056542-2-BInstaller le robinet Convertir à de l’eau mélangée ou filtrée OptionnelMonter l’ensemble du corps de valve Monter l’ensemble du corps de valve Installer la pile Connecter avec les flèches les unes vers les autresConnecter les alimentations Connecter les alimentations Vérifier s’il y a des fuites Compléter l’installationInstaller le couvercle et la poignée Sécuriser les tuyaux et le câble du capteurSymptômes Causes Action recommandée Probables Compléter l’installationPour des installations d’eau mélangée ou filtrée Tourner la DépannageDépannage Kohler Co Français-12 1056542-2-B 1056542-2-B Français-13 Kohler Co Kohler Co Français-14 1056542-2-B Gracias por elegir los productos de Kohler Herramientas y materialesAntes de comenzar Antes de comenzar Kohler Co Español-2 1056542-2-BInstale la grifería Convierta a agua templada o filtrada opcionalInstale el montaje del cuerpo de válvula Instale la pila Conecte los suministros Conecte los suministros Asegure las mangueras y el cable del sensor Termine la instalaciónVerifique que no haya fugas Instale la tapa y la manijaSíntomas Causas Acción recomendada Probables Procedimiento para resolver problemasTermine la instalación UnaProcedimiento para resolver problemas 1056542-2-B Español-11 Kohler Co Kohler Co Español-12 1056542-2-B 1056542-2-B Español-13 Kohler Co 1056542-2-B 1056542-2-B 1056542-2-B USA 1-800-4-KOHLER Canada 1-800-964-5590 México Kohler.com Kohler Co