• SUMMARY OF THE FAULTS

d01: water supply fault (tap)

d07: overflow / anti-leak fault

 

 

d02: draining fault

d08: sprinkling distribution fault

 

 

d03: heating fault

d11: pressure sensor fault

 

 

d04: temperature fault

d12: filling fault (water inlet detection system)

 

 

d05: fault – motor under load

d13: overheating fault

 

 

d06: fault - motor overload

d14 : installation fault : (incorrect drainage

connection or inadequate flow rate and tap).

 

 

 

Tip:

If one of the above faults occurs and you need to call a repair man, remember to tell him the message displayed (d01, d02..) as this information will help him.

• BEFORE CALLING FOR SERVICE

Problem

Possible Causes

What to do?

 

 

 

The door falls heavily when

- Door springs not tensioned

- Tighten the two tensioning

opened (integratable model)

enough to compensate for the

screws accessible in the bot-

 

weight of the panel.

tom section above the front

 

 

feet.

 

 

 

The door does not stay horizontal

- Door springs tensioned too

- Loosen the two tensioning

when open or returns too quickly

much.

screws accessible in the bot-

(integratable model)

 

tom section above the front

 

 

feet.

 

- No wooden panel.

- Fit a temporary wooden panel

 

 

on the appliance and adjust

 

 

the springs.

 

 

 

The door catches when closing

- Appliance not stable

- Adjust the feet.

 

- Door not centred on the tub

- Re-centre by adjusting the

 

 

rear feet.

 

 

 

The upper basket does not stay

- Poor manipulation (the basket

- Act more progressively (see

in the high position

is being pulled upwards too

instructions), one side and

 

quickly)

then the other.

 

 

 

Small leak around or under the

- Leak from the tap.

- Check that a seal is fitted and

appliance (move the appliance

- Leak from the appliance.

retighten the nut.

to locate the leak)

- Close the water tap and call a

 

(Cf. table fault d07).

technician.

 

 

 

 

 

Small leak at the door

- Appliance not stable or not level

- Adjust the feet.

 

- Door not centred on the tub.

- Re-centre by adjusting the rear

 

 

feet.

 

 

 

23

Image 23
Contents Samsung Page EN Contents Use Safety InstructionsInstallation Children’s safetyECONOMICAL, Environmentally Friendly Washing Environmental ProtectionRinsing product dispenser Regenerating salt tank Waste filter Main filterPresentation of the Control Panel EN 3/ Information Water HardnessSoft Hardness TableTest strip 10F10F 10-18F 18-25F 25-40F 40-55F 55-70F For Traditional ProductsTraditional tablets Powders or liquids FigClose the dispenser Loading the multi-purpose tablet dispenserLoading of regenerating salt Fig Regenerating salt indicatorAdjustment lever Rinsing liquid indicator lightUnloading your items AdviceLower Basket Very importantUpper Basket Adjusting the height of the upper basketCutlery basket slides to allow flexible loading Cutlery BasketAnti-leak system Locked programme accessDoor not closed properly Anti-overflow systemProgrammes Table Washing at 70C Rinse Hot rinse Drying By condenser Pre-washWashing at 60C Rinse Hot rinse Drying By condenser Lavage 55/65C Rinse Hot rinse Drying By condenserStopping the machine Delayed start of a B programmeCancelling a programme Immediate start of a programmeRe-installation Cleaning the Waste FiltersPeriodically If not using your dishwasher for a prolonged periodBefore Calling for Service Summary of the FaultsRelating to PROGRAMMING, Display Indicator LightsPoor Washing Results Setting Prioritizing Drying Tener is set correctly. Adjust itCient detergent Detergent Programme temperature too Check the indicator lightPoor Drying Results Poor OperationOriginal Parts Intervention WorkEco Details common to all modelsTests to Standard EN For12 saucers & 1 for 2 cups4 4 4 4 EN Notes