EN 13/ IF OPERATING ANOMALIES OCCUR

• SUMMARY OF THE FAULTS

d01: water supply fault (tap)

d07: overflow / anti-leak fault

 

 

d02: draining fault

d08: sprinkling distribution fault

 

 

d03: heating fault

d11: pressure sensor fault

 

 

d04: temperature fault

d12: filling fault (water inlet detection system)

 

 

d05: fault – motor under load

d13: overheating fault

 

 

d06: fault - motor overload

d14 : installation fault : (incorrect drainage

connection or inadequate flow rate and tap).

 

 

 

Tip:

If one of the above faults occurs and you need to call a repair man, remember to tell him the message displayed (d01, d02..) as this information will help him.

• BEFORE CALLING FOR SERVICE

Problem

Possible Causes

What to do?

 

 

 

The door falls heavily when

- Door springs not tensioned

- Tighten the two tensioning

opened (integratable model)

enough to compensate for the

screws accessible in the bot-

 

weight of the panel.

tom section above the front

 

 

feet.

 

 

 

The door does not stay horizontal

- Door springs tensioned too

- Loosen the two tensioning

when open or returns too quickly

much.

screws accessible in the bot-

(integratable model)

 

tom section above the front

 

 

feet.

 

- No wooden panel.

- Fit a temporary wooden panel

 

 

on the appliance and adjust

 

 

the springs.

 

 

 

The door catches when closing

- Appliance not stable

- Adjust the feet.

 

- Door not centred on the tub

- Re-centre by adjusting the

 

 

rear feet.

 

 

 

The upper basket does not stay

- Poor manipulation (the basket

- Act more progressively (see

in the high position

is being pulled upwards too

instructions), one side and

 

quickly)

then the other.

 

 

 

Small leak around or under the

- Leak from the tap.

- Check that a seal is fitted and

appliance (move the appliance

- Leak from the appliance.

retighten the nut.

to locate the leak)

- Close the water tap and call a

 

(Cf. table fault d07).

technician.

 

 

 

 

 

Small leak at the door

- Appliance not stable or not level

- Adjust the feet.

 

- Door not centred on the tub.

- Re-centre by adjusting the rear

 

 

feet.

 

 

 

24

Image 24
Contents Dishwasher Page EN Contents Safety Instructions InstallationChildren’s safety UseEnvironmental Protection ECONOMICAL, Environmentally Friendly WashingEnsure that the water softener is correctly set see General Presentation of the Dishwasher Description plate After-Sales RefPresentation of the Control Panel Water Hardness Detergents, rinsing liquid or an agent acting as the saltDetergents, rinsing liquid and an agent acting as the salt Hardness Table Test strip10F SoftFor Traditional Products Traditional tabletsPowder or liquid in the distributor’s drawer Fig Advice For MULTI-PURPOSE Products OptionProceed to set the option, if necessary Loading multi-purpose tabletsRegenerating salt indicator Loading the regenerating salt FigAdjustment lever Rinsing product FigChecking the level of rinsing liquid Lower Basket Very importantUpper Basket Cutlery Basket Cutlery basket slides to allow for modu- lable loadingTotal safety Anti-overflow systemAnti-leak system If an anomaly occursProgrammes Table Pre-wash Washing at 60C Rinse Hot rinse Drying By condenserWashing at 45C Rinse Hot rinse Drying By condenser Very short 30-minute Washing at 50C Rinse Hot rinse Drying By condenserCold pre-wash Delayed programme start Immediate programme startCancelling a programme Setting the audible signal’OPTION SCS Systeme Controle Salissure B Stopping the applianceCleaning the Waste Filters Proceed in reverse order, inserting filters C B and then aPeriodically Prolonged stoppageSummary of the Faults Before Calling for ServiceTip Indicator Lights Relating to PROGRAMMING, DisplayPoor Washing Results Tener is set correctly. Adjust it Check the indicator lightProduct Setting Prioritizing Drying Dullness Product Setting prioritizing brilliancePoor Operation Poor Drying ResultsIntervention Work Original PartsDetails common to all models Tests to Standard ENTests according to the mixed IEC 436/DIN 44990 method 4 4 4 4