EN 13/ IF OPERATING ANOMALIES OCCUR
• SUMMARY OF THE FAULTS
d01: water supply fault (tap) | d07: overflow / | |
|
| |
d02: draining fault | d08: sprinkling distribution fault | |
|
| |
d03: heating fault | d11: pressure sensor fault | |
|
| |
d04: temperature fault | d12: filling fault (water inlet detection system) | |
|
| |
d05: fault – motor under load | d13: overheating fault | |
|
| |
d06: fault - motor overload | d14 : installation fault : (incorrect drainage | |
connection or inadequate flow rate and tap). | ||
| ||
|
|
Tip:
If one of the above faults occurs and you need to call a repair man, remember to tell him the message displayed (d01, d02..) as this information will help him.
• BEFORE CALLING FOR SERVICE
Problem | Possible Causes | What to do? |
|
|
|
The door falls heavily when | - Door springs not tensioned | - Tighten the two tensioning |
opened (integratable model) | enough to compensate for the | screws accessible in the bot- |
| weight of the panel. | tom section above the front |
|
| feet. |
|
|
|
The door does not stay horizontal | - Door springs tensioned too | - Loosen the two tensioning |
when open or returns too quickly | much. | screws accessible in the bot- |
(integratable model) |
| tom section above the front |
|
| feet. |
| - No wooden panel. | - Fit a temporary wooden panel |
|
| on the appliance and adjust |
|
| the springs. |
|
|
|
The door catches when closing | - Appliance not stable | - Adjust the feet. |
| - Door not centred on the tub | - |
|
| rear feet. |
|
|
|
The upper basket does not stay | - Poor manipulation (the basket | - Act more progressively (see |
in the high position | is being pulled upwards too | instructions), one side and |
| quickly) | then the other. |
|
|
|
Small leak around or under the | - Leak from the tap. | - Check that a seal is fitted and |
appliance (move the appliance | - Leak from the appliance. | retighten the nut. |
to locate the leak) | - Close the water tap and call a | |
| (Cf. table fault d07). | technician. |
|
| |
|
|
|
Small leak at the door | - Appliance not stable or not level | - Adjust the feet. |
| - Door not centred on the tub. | - |
|
| feet. |
|
|
|
24