ALIGNMENT AND ADJUSTMENTS
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.
ERROR ITEMS AND DIAGNOSTIC CODES
An occurrence of an Error will make a sound of error melody for 5sec and continuously show one of the Error Displays from the following errors.
Error Display | Trigger | Action Taken | |
|
| Check for: | |
tE | The Termistor resistance is | - Clogged lint screen. | |
very low or high. | - Restricted vent system. | ||
| |||
|
| - Check Thermistor resistance. | |
|
|
| |
| Invalid heating Temp in | Check for: | |
HE | - Restricted vent system. | ||
running the dryer | |||
| - Check Thermistor resistance. | ||
|
| ||
|
|
| |
|
| Check for: | |
dE | Running the dryer with door | - Close the door, and run the dryer. | |
open | - Loose or open wire terminals in | ||
| |||
|
| Door Sense circuit. | |
|
|
| |
| Invalid door state for more | Check for: | |
dF | - Loose or open wire terminals in | ||
than 256 milliseconds | |||
| Door Sense circuit. | ||
|
| ||
|
|
| |
| Invalid state of key circuit | Check for: | |
bE2 | - Display PCB key circuit short or | ||
short for 30 secs | |||
| not. | ||
|
| ||
|
|
| |
|
| Check for: | |
| Invalid power source | - Not using regular power source | |
FE | frequency | ||
Frequency | |||
| - Invalid power frequency sense | ||
|
| ||
|
| circuit | |
|
|
| |
| Electronic Control Problem | Check for: | |
AE | - Check PCB and Wire harness. | ||
(Communication Error) | |||
| - Replace PCB. | ||
|
| ||
|
|
| |
Et | Invalid state of Eeprom | Check for : | |
communication | - PCB with Eeprom circuit. | ||
| |||
|
|
|
2