Samsung DV431AEP/XEU manual Test Mode, Service Mode DV431 only, Touch Sensor Data Display Mode

Page 3

ALIGNMENT AND ADJUSTMENTS

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

TEST MODE

Service Mode (DV431 only)

How to enter:

-To enter Service Mode , press Mixed Load Bell + Temp. Keys 3 seconds in normal mode until it sends out a beeping sound.

-If pressing Mixed Load Bell + Temp. Keys in Service mode , it will return Normal mode.

-Even though entering Service mode, the operating cycle will not be influenced.

Touch Sensor Data Display Mode

Definition of Touch Sensor Data Display Mode:

-This mode is default mode of entering service mode.

How to enter:

-With Power On pressing Mixed Load Bell +Temp(DV431) or Wrinkle Prevent + Temp(DV231) for 3 seconds.

-This action will put the dryer into sensor bar touch data mode

-Dryer will display Sensor Bar data.

Cycle Count Mode

Definition of Cycle Count Mode:

-This mode is to bring up the total number of cycles that User have carried out.

How to enter:

-Press the Mixed Load Bell(DV431) orTime(DV231) key in Service Mode.

Software Revision Mode

Definition of Software Revision Mode:

-It is to retrieve its software version

How to enter:

At Service Mode, press Temp until it sends out a beeping sound

ex) In case of “U1 05”, U1 means major version “U1”, 05 means minor version “05”.

-If press Temp key In Software Version Mode, it will return Service Mode.

3

(Technical)DV431AEP-02365F-01_EN.indd 3

2012-04-27 �� 10:22:50

Image 3
Contents Clothes Dryer Alignment and Adjustments Error Items and Diagnostic CodesTrigger Action Taken Cycle Count Mode Test ModeService Mode DV431 only Touch Sensor Data Display ModeContinuous Run Mode Data Display Mode DV431 onlyDefinition of Data Display Mode Trouble Diagnosis Trouble Shooting Flame goes out Igniter does notGlow Gas is ignited butCentrifugal Switch Motor Component Testing ProceduresIf resistance is infinite, replace Radiant sensor GAS Model onlyRadiant Sensor10RS Gas Valve25M01A Resistance value 1 ΩSensor Bars & temperature sensor check Wire system connections Wiring Diagram Wiring Diagram