Samsung DV431AEP/XEU GAS Model only, Radiant Sensor10RS Gas Valve25M01A, Resistance value 1 Ω

Page 9

TROUBLE SHOOTING

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

GAS MODEL ONLY

Radiant Sensor(10RS)

Gas Valve(25M01A)

Resistance value < 1 Ω

Valve 1-2 : Resistance value 1.2K Ω

If resistance is infinite, replace Radiant sensor

Valve 1-3 : Resistance value 0.5K Ω

 

Valve 4-5 : Resistance value 1.2K Ω

 

If resistance is infinity, replace Valve

Igniter(101D)

Resistance value 40~400 Ω

If resistance is infinite, replace IgniterThermostat (60T21 Hi-Limit)230F-50FResistance value < 1 Ω

If resistance is infinity, replace Thermostat

9

(Technical)DV431AEP-02365F-01_EN.indd 9

2012-04-27 �� 10:22:53

Image 9
Contents Clothes Dryer Alignment and Adjustments Error Items and Diagnostic CodesTrigger Action Taken Service Mode DV431 only Test ModeTouch Sensor Data Display Mode Cycle Count ModeContinuous Run Mode Data Display Mode DV431 onlyDefinition of Data Display Mode Trouble Diagnosis Trouble Shooting Glow Igniter does notGas is ignited but Flame goes outCentrifugal Switch Motor Component Testing ProceduresRadiant Sensor10RS Gas Valve25M01A GAS Model onlyResistance value 1 Ω If resistance is infinite, replace Radiant sensorSensor Bars & temperature sensor check Wire system connections Wiring Diagram Wiring Diagram