Continuous Run Mode

Power On state

 

Mixed Load Bell +Dry Level(DV431) or

(Normal user mode)

 

Wrinkle Prevent + Time(DV231) 7 SEC

 

 

 

Continuous Run Mode

How to enter:

-Press Mixed Load Bell +Dry Level(DV431) or Wrinkle Prevent + Time(DV231) for 7 sec during Power On State (normal user mode).

-Once in Continuous Run Mode, display “CC” for 1 sec and the remaining time for 2 sec in turns.

-The previous cycle will restart during Continuous Run Mode until the mode is deactivated.

-During Continuous Run Mode, press Mixed Load Bell +Dry Level(DV431) or Wrinkle Prevent + Time(DV231) for 7 seconds to go back to normal user mode.

Data Display Mode (DV431 only)

How to Enter:

-With Power On, press AdjustUp Key + AdjsutDown Key for 7 seconds until it sends out a beeping sound .

-If not pressed any keys for 5 minutes, it will be set back from Data Display Mode

-If pressing AdjustUp Key in this mode, Display Mode will be incresed.

-If pressing AdjustDown Key in this mode, Display Mode will be decresed.

Definition of Data Display Mode:

-Display Mode 1 : Temperature data

-Display Mode 2 : Average Touch Sensor data for 1 minute

-Display Mode 3 : Average Temperature data for 1 minute

4

(Technical)DV431AEP-02365F-01_EN.indd 4

2012-04-27 �� 10:22:51

Image 4 Contents
Clothes Dryer Error Items and Diagnostic Codes Alignment and AdjustmentsTrigger Action Taken Test Mode Service Mode DV431 onlyTouch Sensor Data Display Mode Cycle Count ModeData Display Mode DV431 only Continuous Run ModeDefinition of Data Display Mode Trouble Diagnosis Trouble Shooting Igniter does not GlowGas is ignited but Flame goes outComponent Testing Procedures Centrifugal Switch MotorGAS Model only Radiant Sensor10RS Gas Valve25M01AResistance value 1 Ω If resistance is infinite, replace Radiant sensorSensor Bars & temperature sensor check Wire system connections Wiring Diagram Wiring Diagram